Skip to main content
QUICK REVIEW

[Paper Review] Multi-scale Domain-adversarial Multiple-instance CNN for Cancer Subtype Classification with Unannotated Histopathological Images

Noriaki Hashimoto, Daisuke Fukushima|arXiv (Cornell University)|Jan 6, 2020
AI in cancer detectionComputer Science36 references18 citations
TL;DR

This paper proposes a multi-scale domain-adversarial multiple-instance CNN (MS-DA-MIL) for cancer subtype classification from unannotated whole slide images (WSIs), combining multiple-instance learning to handle weakly labeled data, domain adversarial normalization to mitigate staining variations, and multi-scale feature extraction to capture morphological details across resolutions. The method achieved 87.1% accuracy on malignant lymphoma classification, outperforming standard CNNs and matching pathologist-level performance.

ABSTRACT

We propose a new method for cancer subtype classification from histopathological images, which can automatically detect tumor-specific features in a given whole slide image (WSI). The cancer subtype should be classified by referring to a WSI, i.e., a large-sized image (typically 40,000x40,000 pixels) of an entire pathological tissue slide, which consists of cancer and non-cancer portions. One difficulty arises from the high cost associated with annotating tumor regions in WSIs. Furthermore, both global and local image features must be extracted from the WSI by changing the magnifications of the image. In addition, the image features should be stably detected against the differences of staining conditions among the hospitals/specimens. In this paper, we develop a new CNN-based cancer subtype classification method by effectively combining multiple-instance, domain adversarial, and multi-scale learning frameworks in order to overcome these practical difficulties. When the proposed method was applied to malignant lymphoma subtype classifications of 196 cases collected from multiple hospitals, the classification performance was significantly better than the standard CNN or other conventional methods, and the accuracy compared favorably with that of standard pathologists.

Motivation & Objective

  • To address the high cost and impracticality of annotating tumor regions in whole slide images (WSIs) for cancer subtype classification.
  • To develop a deep learning model that mimics pathologists’ diagnostic process by identifying tumor-specific features across multiple magnification scales.
  • To improve robustness against staining variations across hospitals and specimens without requiring domain-specific annotations.
  • To achieve high classification accuracy comparable to expert pathologists using only weakly labeled WSIs.

Proposed method

  • Integrates multiple-instance learning (MIL) by treating each WSI as a bag of patches, where only the presence of at least one tumor-positive patch is required for a positive label.
  • Applies domain adversarial normalization to align feature distributions across different staining conditions, reducing domain shift without requiring labeled domain data.
  • Employs multi-scale input processing by feeding WSIs at 10x and 20x magnification to the network, enabling detection of features at varying resolutions.
  • Uses a patch-based CNN (VGG16) for feature extraction, followed by attention mechanisms to highlight tumor-relevant patches within each bag.
  • Combines attention-based MIL with domain adversarial training to jointly optimize for both classification and domain-invariant representation learning.
  • Applies cross-entropy loss for classification and domain adversarial loss to disentangle staining-specific features from biologically relevant ones.

Experimental results

Research questions

  • RQ1Can a deep learning model effectively classify cancer subtypes from unannotated whole slide images without requiring patch-level tumor annotations?
  • RQ2How can domain adversarial training improve model generalization across different staining protocols in multi-center histopathology data?
  • RQ3Does multi-scale input processing enhance the detection of morphologically diverse tumor features across different magnification levels?
  • RQ4To what extent does the proposed method mimic the diagnostic behavior of human pathologists in focusing on tumor regions across scales?

Key findings

  • The proposed MS-DA-MIL method achieved 87.1% accuracy with a standard error of ±0.028 on 196 malignant lymphoma WSIs, significantly outperforming standard CNN and other conventional methods.
  • MS-DA-MIL achieved 85.7% accuracy at 20x magnification and 83.6% at 10x, demonstrating improved performance over DA-MIL and patch-based baselines.
  • Attention maps generated by the model localized high attention weights on CD20 immunohistochemistry-positive regions, confirming that the model focuses on true tumor areas.
  • The model showed robustness to staining variations, as domain adversarial normalization effectively reduced domain shift across hospitals and specimens.
  • The method successfully identified tumor-specific features at multiple scales, with some cases showing high attention at 10x and others at 20x, reflecting pathologist-like multi-scale analysis.
  • The performance of MS-DA-MIL was comparable to that of standard pathologists, as confirmed by immunohistochemical validation of attention regions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.