[Paper Review] Multi-Task Generative Adversarial Network for Handling Imbalanced Clinical Data
This paper proposes a multi-task generative adversarial network (GAN) that jointly performs medical image semantic segmentation and disease classification to address class imbalance in clinical data. By integrating selective weighted loss with a conditional GAN framework—where the generator produces segmentation and classification outputs, and the discriminator distinguishes real from generated outputs—the model achieves state-of-the-art performance on ACDC-2017 and competitive results on BraTS-2017, with 98.61% accuracy in glioma classification and 94% accuracy in cardiac segmentation.
We propose a new generative adversarial architecture to mitigate imbalance data problem for the task of medical image semantic segmentation where the majority of pixels belong to a healthy region and few belong to lesion or non-health region. A model trained with imbalanced data tends to bias towards healthy data which is not desired in clinical applications. We design a new conditional GAN with two components: a generative model and a discriminative model to mitigate imbalanced data problem through selective weighted loss. While the generator is trained on sequential magnetic resonance images (MRI) to learn semantic segmentation and disease classification, the discriminator classifies whether a generated output is real or fake. The proposed architecture achieved state-of-the-art results on ACDC-2017 for cardiac segmentation and diseases classification. We have achieved competitive results on BraTS-2017 for brain tumor segmentation and brain diseases classification.
Motivation & Objective
- To address the challenge of class imbalance in medical image segmentation, where healthy tissue vastly outnumbers lesion regions.
- To improve model sensitivity to minority (abnormal) classes by mitigating bias toward majority (healthy) classes in training.
- To develop a unified deep learning framework that jointly performs semantic segmentation of organs and abnormal tissues, along with disease classification.
- To leverage multi-task learning to enhance performance on both segmentation and classification tasks through shared feature representations.
- To evaluate the method on real-world clinical benchmarks, including ACDC-2017 and BraTS-2017, under standard evaluation protocols.
Proposed method
- The proposed architecture uses a conditional GAN with a generator that maps 2D multi-modal MRI sequences to semantic segmentation maps and disease classification outputs.
- The discriminator evaluates whether the generator’s output is real (ground truth) or fake (generated), using a patch-based adversarial loss.
- A selective weighted categorical cross-entropy loss is applied to segmentation, where class weights are inversely proportional to class frequency, with square root normalization to prevent extreme values.
- An additional weighted ℓ1 loss is used for disease classification to handle class imbalance.
- Bidirectional LSTMs are incorporated into both generator and discriminator to model temporal dependencies in sequential MRI slices.
- The overall loss combines adversarial, segmentation, and classification losses, enabling end-to-end training of the multi-task network.
Experimental results
Research questions
- RQ1Can a multi-task GAN architecture effectively mitigate class imbalance in medical image segmentation without relying on data-level re-sampling?
- RQ2How does the integration of selective weighted loss improve sensitivity to minority (lesion) classes in semantic segmentation?
- RQ3To what extent can joint learning of segmentation and disease classification improve performance on both tasks compared to single-task models?
- RQ4Does the use of a conditional GAN with adversarial training enhance the realism and accuracy of segmentation outputs in clinical imaging?
- RQ5How does the proposed method compare to state-of-the-art models on standardized benchmarks like ACDC-2017 and BraTS-2017?
Key findings
- The proposed method achieved 98.61% accuracy in classifying high- and low-grade glioma on BraTS-2017, outperforming prior cascade architectures.
- On ACDC-2017, the model achieved a Dice score of 0.95 for left ventricle, 0.93 for right ventricle, and 0.92 for myocardium, with Hausdorff distances of 8.11, 8.17, and 8.38 mm respectively.
- The model achieved 94% accuracy in cardiac segmentation across end-diastolic and end-systolic phases, outperforming several top-ranked methods on the ACDC benchmark.
- The use of selective weighted loss significantly improved sensitivity to minority classes, with 87% sensitivity for whole tumor region and 88% for enhancing tumor in BraTS-2017.
- The inference time was efficient at only 58 seconds per 155-slice brain MRI, demonstrating practical feasibility for clinical deployment.
- Qualitative results on ACDC-2017 showed accurate segmentation of left ventricle (red), right ventricle (blue), and myocardium (green), with minimal false positives in abnormal regions.
Read this paper