Skip to main content
QUICK REVIEW

[Paper Review] New Time-Dependent WFC3/IR Inverse Sensitivities

A. Calamida, Mariarosa Marinelli|arXiv (Cornell University)|Feb 12, 2026
CCD and CMOS Imaging SensorsEngineering0 citations
TL;DR

This paper delivers time-dependent inverse sensitivities for the WFC3/IR channel, introduces updated filter throughputs and a new IMPHTTAB, and validates improved photometric precision over 14–15 years.

ABSTRACT

We present new time-dependent inverse sensitivities for the WFC3/IR channel. These were calculated using the sensitivity change slopes measured by \citet{2024wfc..rept....6M} and photometry of five CALSPEC standards (the white dwarfs GRW+70~5824, GD~153, GD~71, G191B2B, and the G-type star P330E) collected from 2009 to 2023. The new inverse sensitivities account for losses of 1-2\% over 15 years, depending on wavelength, and provide an internal photometric precision better than 0.5\% for all wide--, medium--, and narrow-band filters. An updated version of exttt{calwf3} (v3.7.2) has been developed for use with a new time-dependent image photometry table (IMPHTTAB) and will be used to update the image header photometric keywords following MAST reprocessing, expected in late-2024. Alternatively, the new inverse sensitivities may be computed by the user for a specific observation date by running exttt{stsynphot}.

Motivation & Objective

  • Provide time-dependent inverse sensitivities for WFC3/IR across all 15 imaging filters (2009–2023 data).
  • Quantify wavelength-dependent sensitivity losses and correct CALSPEC standard star photometry accordingly.
  • Develop updated filter throughput curves and an image photometry lookup table (IMPHTTAB) compatible with calwf3 v3.7.2.
  • Validate the new calibrations with standard stars and PSF/aperture photometry across multiple epochs.
  • Offer practical guidance for users to apply time-dependent calibrations via calwf3 and stsynphot.

Proposed method

  • Compute time-dependent sensitivity corrections using slopes from Marinelli et al. (2024) and CALSPEC standard-star photometry (five standards).
  • Correct standard-star photometry for sensitivity losses prior to deriving inverse sensitivities.
  • Generate synthetic count rates with stsynphot using updated CALSPEC SEDs and filter curves; compare observed vs. synthetic rates.
  • Derive multiplicative corrections to filter curves to produce new time-dependent throughputs (wfc3_ir_FXXXX_008_syn.fits).
  • Calculate inverse sensitivities S' from C/F using the updated synthetic F and time-corrected observed counts; provide values in AB, Vega, and ST systems (Table 3).
  • Create and test a new IMPHTTAB reference file and time-dependent filter tables for use with calwf3 v3.7.2.
Figure 1: Ratio of the observed to synthetic count rates, calculated as the weighted mean of the five CALSPEC standard stars in the 15 WFC3/IR filters: wide (black circles), medium (red diamonds), and narrow (blue squares). Error bars are displayed and only wide- and medium-band filters are labeled.
Figure 1: Ratio of the observed to synthetic count rates, calculated as the weighted mean of the five CALSPEC standard stars in the 15 WFC3/IR filters: wide (black circles), medium (red diamonds), and narrow (blue squares). Error bars are displayed and only wide- and medium-band filters are labeled.

Experimental results

Research questions

  • RQ1What are the time-dependent sensitivity loss rates for WFC3/IR across its 15 filters over 2009–2023?
  • RQ2How do updated time-dependent inverse sensitivities compare to the 2020 calibration, and what is the impact on zeropoints across wavelength?
  • RQ3Can the new time-dependent throughputs reproduce observed-to-synthetic count-rate ratios with sub-percent dispersion?
  • RQ4Do time-dependent PHOTFLAM values improve photometric precision and flatten temporal trends in real data (e.g., Sgr A* field, GD153)?
  • RQ5What are the practical steps for users to apply the new calibrations via calwf3 v3.7.2 and stsynphot?

Key findings

  • Time-dependent inverse sensitivities show 1–2% total decrease in flux over ~15 years, varying with wavelength.
  • Mean observed-to-synthetic count-rate ratio for the five CALSPEC standards across all filters is 1.003 ± 0.003 before considering time dependence, improving with the new time-dependent corrections (dispersion ~0.5% RMS).
  • New filter throughput curves (2024) and time-dependent throughputs yield observed-synthetic ratios clustered around 1.0 with RMS ~0.5% for wide/medium bands.
  • New zero-points differ from 2020 values by about 0.16% on average at the reference epoch, with larger differences (~2%) at bluer wavelengths when evaluating current epoch (July 2024).
  • PHOTFLAM values increase over time as detector sensitivity declines; calibrations reduce photometric dispersion and flatten temporal trends in multiple tests (e.g., Sgr A* field, F125W tests).
  • Calibration pipeline calwf3 v3.7.2 will populate epoch-dependent PHOTFLAM/PHOTFNU in image headers and requires updated CRDS/IMPHTTAB files.
Figure 2: Ratio of the observed to synthetic count rates in five wide-band and four medium-band WFC3/IR filters as a function of pivot wavelength for the five CALSPEC standards used in the calibration. The dashed black line indicates a unity ratio. Error bars are displayed.
Figure 2: Ratio of the observed to synthetic count rates in five wide-band and four medium-band WFC3/IR filters as a function of pivot wavelength for the five CALSPEC standards used in the calibration. The dashed black line indicates a unity ratio. Error bars are displayed.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.