Skip to main content
QUICK REVIEW

[Paper Review] Noise spectroscopy of a quantum-classical environment with a diamond qubit

Santiago Hernández-Gómez, Francesco Poggiali|DSpace@MIT (Massachusetts Institute of Technology)|Aug 24, 2018
Diamond and Carbon-based Materials ResearchMaterials Science8 citations
TL;DR

This paper presents a noise spectroscopy protocol using a diamond nitrogen-vacancy (NV) center to characterize a hybrid quantum-classical environment, combining resolved nuclear spins and a collective quantum bath. By tuning the magnetic bias field, the method reconstructs noise spectral density even under short coherence times, demonstrating predictive power for qubit dynamics under various dynamical decoupling sequences, especially revealing the need for multiple classical noise models in the strong-coupling regime due to qubit-bath backaction.

ABSTRACT

Knowing a quantum system's environment is critical for its practical use as a quantum device. Qubit sensors can reconstruct the noise spectral density of a classical bath, provided long enough coherence time. Here we present a protocol that can unravel the characteristics of a more complex environment, comprising both unknown coherently coupled quantum systems, and a larger quantum bath that can be modeled as a classical stochastic field. We exploit the rich environment of a Nitrogen-Vacancy center in diamond, tuning the environment behavior with a bias magnetic field, to experimentally demonstrate our method. We show how to reconstruct the noise spectral density even when limited by relatively short coherence times, and identify the local spin environment. Importantly, we demonstrate that the reconstructed model can have predictive power, describing the spin qubit dynamics under control sequences not used for noise spectroscopy, a feature critical for building robust quantum devices. At lower bias fields, where the effects of the quantum nature of the bath are more pronounced, we find that more than a single classical noise model are needed to properly describe the spin coherence under different controls, due to the back action of the qubit onto the bath.

Motivation & Objective

  • To develop a noise spectroscopy method capable of characterizing complex environments with both coherent quantum systems and a classical-like bath.
  • To overcome limitations of traditional noise spectroscopy under short qubit coherence times.
  • To investigate the impact of qubit-bath backaction on noise modeling in the strong-coupling regime.
  • To validate the predictive power of reconstructed noise models across different dynamical decoupling sequences.
  • To demonstrate that multiple classical noise models are required when quantum bath effects dominate.

Proposed method

  • The protocol uses a nitrogen-vacancy (NV) electron spin in diamond as a quantum sensor to probe its local environment, including 13C nuclear spins.
  • Noise spectral density (NSD) is reconstructed via analysis of spin coherence under various dynamical decoupling (DD) sequences, including UDD, XY-8, and AXY-8.
  • Two distinct NSD extraction methods are employed: one based on $T_2^L$ measurements and another via simultaneous fitting of population data $P_n$ across multiple DD sequences.
  • The NSD center is fixed at the Larmor frequency $\nu_L = B\gamma_{C_{13}}$, with free parameters for offset, amplitude, and width.
  • The method is validated by comparing simulations to experimental data across varying magnetic fields and pulse sequences.
  • A two-model picture is adopted in the strong-coupling regime, combining results from both NSD extraction methods to improve predictive accuracy.

Experimental results

Research questions

  • RQ1Can noise spectroscopy be effectively applied to environments with both coherent quantum systems and a collective quantum bath?
  • RQ2How does qubit-bath backaction affect the validity of classical noise models in the strong-coupling regime?
  • RQ3Can a reconstructed noise model predict qubit dynamics under control sequences not used during spectroscopy?
  • RQ4Under what conditions is a single classical noise model insufficient for accurate description?
  • RQ5How do different dynamical decoupling sequences influence the reliability of noise spectral density reconstruction?

Key findings

  • The reconstructed noise model successfully predicts NV spin dynamics under control sequences not used during spectroscopy, demonstrating predictive power.
  • In the weak-coupling regime (high magnetic field), a single classical noise model suffices and accurately describes coherence under various DD sequences.
  • In the strong-coupling regime (low magnetic field), multiple classical noise models are required due to qubit-induced bath modifications, especially under narrow-filter DD sequences.
  • The $T_2^L$-based NSD extraction method predicts dynamics well only for sequences with low pulse numbers (e.g., Hahn echo), due to deep coherence collapses.
  • Simultaneous fitting of $P_n$ data across sequences improves accuracy for high-pulse-number sequences but fails for low-pulse sequences like CPMG with $n=2$.
  • The two-model approach—combining $T_2^L$ and multi-sequence fitting—yields $\chi_\nu^2$ values comparable to the $T_2^L$ method in the weak-coupling regime, confirming robustness.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.