[Paper Review] Note on Drexel tests of the IMB R1408 PMTs used in the inner veto of both far and near detectors of the Double Chooz experiment

K. Zbiri|arXiv (Cornell University)|Apr 20, 2011
Particle Detector Development and PerformancePhysics and Astronomy4 citations
TL;DR

This study evaluates 250 IMB R1408 photomultiplier tubes (PMTs) using photo-statistics and light pulser methods to select 156 for use in the inner veto system of the Double Chooz experiment's far and near detectors. The key finding is that new tapered bases improve saturation performance by 2–3 times compared to linear bases at the same gain, without altering gain or high voltage settings.

ABSTRACT

This report is related to the testing performed at Drexel University of 250 R1408 PMTs. Based on this testing, 156 R1408 PMTs were chosen to be used in the inner veto of the detectors of the Double Chooz experiment.

Motivation & Objective

  • To ensure the reliability and performance of 250 used R1408 PMTs intended for the Double Chooz experiment's inner veto system.
  • To determine optimal high voltage settings for a target gain of ~10⁷, ensuring consistent PMT response across the array.
  • To compare the performance of old linear bases, new linear bases, and new tapered bases in terms of gain, saturation, and dark noise.
  • To validate calibration techniques—photo-statistics and light pulser methods—for accurate PMT characterization.
  • To select 156 PMTs with optimal performance for deployment in the Double Chooz far and near detectors.

Proposed method

  • Employed the photo-statistics method to determine PMT gain by measuring the variance-to-mean ratio of ADC pulse amplitudes across varying light levels.
  • Used a ²⁴¹Am α-source coupled to a NaI(Tl) scintillator to generate monochromatic light pulses for gain calibration via the light pulser method.
  • Measured the maximum pulse amplitude and threshold voltage as functions of applied high voltage to identify the gain=10⁷ operating point.
  • Cross-verified gain values using both the photo-statistics method and light pulser method to ensure consistency and accuracy.
  • Compared performance across three base types—old linear, new linear, and new tapered—by measuring gain, saturation level, and dark noise rate at fixed high voltage.
  • Fitted gain vs. high voltage data in log-log scale to assess linearity and confirm 13-stage amplification behavior, using the relation G = KV^(Nα).

Experimental results

Research questions

  • RQ1What is the optimal high voltage setting that yields a gain of ~10⁷ for each R1408 PMT, ensuring consistent performance across the array?
  • RQ2How do different PMT base types (old linear, new linear, new tapered) affect saturation performance and gain at the same high voltage?
  • RQ3To what extent do the photo-statistics and light pulser calibration methods agree in determining PMT gain and saturation?
  • RQ4How does the use of a new tapered base improve linearity and saturation performance compared to the original linear base?
  • RQ5What is the impact of base termination resistance on measured gain, and how does it vary between different base types?

Key findings

  • The new tapered base improved saturation performance by 2–3 times compared to the new linear base at the same gain (i.e., same high voltage), with 508 pe saturation for PMT#139 using the tapered base versus 189 pe with the new linear base.
  • At 1300 V, PMT#139 with the new tapered base achieved a gain of 1.13×10⁷ and a saturation level of 508 photo-electrons, while the same PMT with the old linear base reached only 165 pe at 1220 V.
  • The gain measured with the new linear and new tapered bases was nearly identical at the same high voltage, indicating that the back termination resistance is the dominant factor in gain variation.
  • The ratio of gain with the new tapered base to the old linear base ranged from 0.694 to 0.903 across different PMTs, with an average of ~0.75, indicating a consistent reduction in gain due to base design.
  • The new tapered base provided a more linear gain response with increasing high voltage, with a fit compatible with 13-stage amplification (G ∝ V^(Nα), α ≈ 0.7).
  • The dark noise rate was lowest (1.6 kHz) for PMT#139 with the new tapered base at 0.221 pe, compared to 2.4 kHz for the same PMT with the old linear base, indicating improved noise performance.

Read this paper