[Paper Review] Numerical evaluation of AC losses in an HTS insert coil for high field magnet during its energization
This study numerically evaluates AC losses in a high-temperature superconducting (HTS) insert coil for a 25-T cryogen-free superconducting magnet during energization using a slab approximation model. The analysis accounts for axial and radial components of local magnetic fields, transport current effects, and inter-turn magnetic interactions, revealing that perpendicular-field losses dominate over time and total losses reach ~5 W at 60 minutes—slightly exceeding the 3 W cooling capacity, indicating potential thermal stability challenges.
AC losses in a high temperature superconducting (HTS) insert coil for a 25-T cryogen-free superconducting magnet are numerically calculated during its energization, assuming slab approximation. The HTS insert coil consists of 68 single pancakes wound with coated conductors and generating a central magnetic field of 11.5 T, in addition to a contribution of 14.0 T from a set of low temperature superconducting (LTS) outsert coils. Both the HTS and LTS coils are cooled using cryocoolers, and energized simultaneously up to 25.5 T with a constant ramp rate for 60 min. The influences of the magnitudes and orientations of the locally applied magnetic fields, magnetic interactions between turns, and the transport currents flowing in the windings are taken into account in the AC loss calculations. The locally applied fields are separated into axial and radial components, and the individual contributions of these field components to the AC losses are summed simply to obtain the total losses. The contribution of the axial field component to the total AC loss is large at the early stages of the energization, whereas the total losses monotonically increase with time after the contribution of the radial field component becomes sufficiently large.
Motivation & Objective
- To evaluate AC losses in an HTS insert coil during energization in a high-field cryogen-free superconducting magnet.
- To assess the impact of axial and radial components of locally applied magnetic fields on AC loss generation.
- To investigate the influence of transport current and inter-turn magnetic interactions on AC loss in HTS pancake coils.
- To validate the slab approximation method against finite element method (FEM) simulations for accuracy in loss estimation.
- To determine whether cooling power limitations could lead to thermal runaway during the 60-minute energization process.
Proposed method
- The AC losses are calculated using a slab approximation model for coated conductors, assuming infinite slab geometry with thickness equal to the superconducting layer thickness.
- The model separates local magnetic fields into axial (parallel to tape) and radial (perpendicular to tape) components, treating their contributions independently.
- Theoretical expressions for perpendicular- and parallel-field losses are derived based on critical-state model assumptions and integrated over time using constant ramp rate (60 min to 25.5 T).
- Loss contributions from transport current are included via modified critical current density expressions under combined field and current loading.
- Finite element method (FEM) simulations are used as a benchmark to validate the slab approximation results, particularly for field penetration and end-effect effects.
- Total AC loss is obtained by summing perpendicular- and parallel-field loss contributions using equation (3).
Experimental results
Research questions
- RQ1How do axial and radial components of the local magnetic field contribute to AC losses during the energization of an HTS insert coil?
- RQ2To what extent does the transport current in the HTS tape affect the magnitude of AC losses under combined field and current loading?
- RQ3Can the slab approximation accurately predict AC losses in a multi-pancake HTS coil with complex field and current distributions?
- RQ4What is the time evolution of total AC loss during a 60-minute energization ramp, and does it exceed the cooling power of the cryocoolers?
- RQ5How do inter-turn magnetic interactions influence the distribution and magnitude of AC losses across different pancake turns?
Key findings
- The axial component of the magnetic field contributes significantly to AC losses during the initial 5 minutes of energization, peaking before declining.
- Perpendicular-field losses dominate after approximately 10 minutes and increase monotonically with time, becoming the primary loss contributor.
- The total AC loss reaches approximately 5 W at the end of the 60-minute energization, exceeding the 3 W cooling power of the cryocoolers at 4.2 K.
- The slab approximation shows good agreement with FEM simulations, with minor discrepancies observed near field penetration boundaries and at turn ends.
- Transport current has a significant influence on perpendicular-field losses but negligible effect on parallel-field losses.
- The critical current density decreases over time due to field and current exposure, leading to reduced parallel-field losses after the initial peak.