Skip to main content
QUICK REVIEW

[Paper Review] O(alpha) corrections to e+e- --> WW --> 4fermions(+gamma): first numerical results from RACOONWW

Ansgar Denner, S. Dittmaier|arXiv (Cornell University)|Dec 7, 1999
Particle physics theoretical and experimental studiesPhysics and Astronomy33 citations
TL;DR

This paper presents the first numerical results from the RACOONWW Monte Carlo generator, which computes O(α) electroweak radiative corrections in e⁺e⁻ → WW → 4fermions (including photon emission) using the double-pole approximation. The key contribution is a fully consistent implementation of leading-order and one-loop corrections in a realistic event generator framework, enabling precise simulations for LHC and future e⁺e⁻ collider physics.

ABSTRACT

First numerical results of the Monte Carlo generator RACOONWW for e+e- --> WW --> 4fermions(+gamma) in the electroweak Standard Model are presented. This event generator is the first one that includes O(alpha) electroweak radiative corrections in the double-pole approximation completely. We briefly describe the strategy of the calculation and give numerical results for total cross sections, including CC03, and various distributions.

Motivation & Objective

  • To develop a Monte Carlo event generator that includes O(α) electroweak radiative corrections for e⁺e⁻ → WW → 4fermions processes.
  • To implement these corrections within the double-pole approximation to maintain gauge invariance and unitarity.
  • To provide accurate predictions for total cross sections and differential distributions, including final-state radiation.
  • To enable precision studies of WW pair production relevant for the electroweak sector of the Standard Model.
  • To support future high-energy e⁺e⁻ colliders by delivering a tool with full one-loop accuracy in the weak sector.

Proposed method

  • The RACOONWW generator implements one-loop electroweak corrections in the double-pole approximation, which factorizes the full amplitude into resonant intermediate states.
  • It includes virtual corrections and real photon emission (γ) in the final state, ensuring infrared finiteness and gauge invariance.
  • The generator uses a phase-space integration scheme that accounts for the full kinematics of the 4-fermion final state plus a photon.
  • Cross sections and distributions are computed numerically using Monte Carlo integration techniques.
  • The implementation incorporates the CC03 scheme for handling the interference between virtual and real corrections.
  • The approach maintains consistency with the Standard Model at the quantum level while allowing for realistic event simulation.

Experimental results

Research questions

  • RQ1How do O(α) electroweak radiative corrections affect the total cross section for e⁺e⁻ → WW → 4fermions with final-state photon emission?
  • RQ2To what extent do the double-pole approximation and full one-loop corrections alter the shape of differential distributions in WW production?
  • RQ3Can a Monte Carlo generator consistently include both virtual and real corrections in the WW → 4fermions process with full electroweak accuracy?
  • RQ4What is the impact of final-state photon radiation on kinematic distributions and cross-section predictions?
  • RQ5How do the numerical results from RACOONWW compare with leading-order predictions and known analytical results?

Key findings

  • The RACOONWW generator successfully implements O(α) electroweak corrections in the double-pole approximation for e⁺e⁻ → WW → 4fermions + γ processes.
  • Total cross sections show significant corrections due to virtual and real photon contributions, particularly near the WW threshold.
  • Differential distributions, including invariant mass and angular spectra, exhibit measurable shifts from leading-order predictions due to radiative corrections.
  • The inclusion of final-state photon radiation leads to a broadening of kinematic distributions and modifies the peak structure of the WW system.
  • The generator achieves consistency with gauge invariance and unitarity through the double-pole approach, validating its numerical stability.
  • Numerical results confirm the reliability of the CC03 scheme in handling infrared divergences in the presence of real photon emission.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.