Skip to main content
QUICK REVIEW

[Paper Review] Observation of the Forbush decrease on 2024 May 10, using the ALPAQUITA air-shower array at the 70-1000 GV rigidity range

M. Anzorena, E. De la Fuente|arXiv (Cornell University)|Jan 13, 2026
Astrophysics and Cosmic PhenomenaPhysics and Astronomy0 citations
TL;DR

The study reports the Forbush decrease on 2024 May 10 detected by ALPAQUITA (Any1 and Any2 counting modes). Any1 shows a 4.26% decrease at a 76 GV median rigidity, while Any2 sets a 2-sigma upper limit of 0.95% at 960 GV, indicating a hard-to-soft spectral behavior at high rigidities.

ABSTRACT

The Andes Large area PArticle detector for Cosmic ray and Astronomy (ALPACA) is a new air-shower array experiment under construction in the Bolivian Andes, and its prototype ALPAQUITA surface array has been operating since 2023 April. In addition to the traditional $\ge$3-hit or $\ge$4-hit coincidences to trigger recording air-shower events, ALPAQUITA records the counting rates of the $\ge$1-hit and $\ge$2-hit events (Any1 and Any2, respectively). We report a successful detection of a Forbush decrease occurred on 2024 May 10 caused by a passage of an interplanetary shock formed ahead of the Interplanetary Coronal Mass Ejection. The amplitude detected in the Any1 rate is 4.26$\pm$0.33% at the median primary rigidity of 76GV which is consistent with the observations with the worldwide neutron monitor and muon detector networks. Under the assumption of a power-law rigidity spectrum, we renormalized the errors of the observed amplitude ($A_{obs}$) and fitted them as a function of the median primary rigidity ($R_{m}$) of each detector and observational method. The result $A_{obs} = (10.9\% \pm 0.9\%) imes (R_{m}/10\,GV)^{-0.55 \pm 0.07}$ exhibits a hard nature of this event. Our non-detection in the Any2 rate decrease constrains the amplitude with a 2$σ$ upper limit to be 0.95% at 960GV. This marginally suggests an existence of a spectral softening between 100GV and 1000GV as also suggested by the Misato underground muon detector at 145GV. Although a strong geomagnetic storm was observed during this period, we conclude it does not impact our results. Our novel technique realizes a unique coverage to study the behavior of the Forbush decreases at the highest rigidity.

Motivation & Objective

  • Motivate study of Forbush decreases (FDs) at high cosmic-ray rigidities beyond 100 GV.
  • Demonstrate ALPAQUITA’s counting-mode capability (Any1/Any2) to access higher rigidities.
  • Characterize the rigidity dependence of the FD amplitude and compare with NM and muon detector networks.

Proposed method

  • Operate the ALPAQUITA surface array (97 counters, 18,450 m^2) at 4740 m a.s.l. to record Any1 (single-count rates) and Any2 (2-hit coincidences) alongside traditional 3/4-hit air-shower triggers Any3/Any4.
  • Use Monte Carlo simulations (CORSIKA with FLUKA and QGSJET II-04; GEANT4-based detector response) to map counting-mode rigities: Any1 ~ 76 GV, Any2 ~ 960 GV, Any3 ~ 2290 GV, Any4 ~ 3340 GV.
  • Correct rate data for atmospheric pressure effects using site coefficients, and apply accidental-coincidence corrections for Any2.
  • Extract FD amplitude by comparing to a pre-FD base level defined from May 8-9 and compute uncertainties.
  • Fit the observed amplitude versus median rigidity with a power-law A_obs ∝ (R_m / 10 GV)^(-γ) and discuss within the context of existing NM/GMDN/Misato data.
Figure 1: Pressure corrected time profiles of the NM (black curves) and GMDN (red curves) relative counting rate during the FD started at around 17 UT, May 10.
Figure 1: Pressure corrected time profiles of the NM (black curves) and GMDN (red curves) relative counting rate during the FD started at around 17 UT, May 10.

Experimental results

Research questions

  • RQ1What is the FD amplitude as a function of median primary rigidity in the 70-1000 GV range?
  • RQ2Can ALPAQUITA Any2 provide constraints on high-rigidity FD behavior beyond 100 GV?
  • RQ3How does ALPAQUITA data compare with NM and muon-detector results for the 2024 May 10 FD?
  • RQ4Is there evidence for spectral softening of FD amplitudes at higher rigidities?
  • RQ5What are the geomagnetic and anisotropy considerations affecting high-rigidity FD measurements?

Key findings

  • Any1 detects a FD amplitude of 4.26% ± 0.33% at a median rigidity of 76 GV.
  • Any2 shows no significant FD decrease, with a 2σ upper limit of 0.95% at 960 GV.
  • A power-law fit across diverse detectors yields A_obs = (10.9% ± 0.9%) × (R_m / 10 GV)^(-0.55 ± 0.07).
  • The Any2 upper limit marginally suggests spectral softening between 100 GV and 1000 GV, consistent with Misato detector indications.
  • Geomagnetic storm effects are assessed and deemed negligible for the conclusions drawn.
  • ALPAQUITA’s Any2 mode demonstrates unique high-rigidity coverage for FD studies, motivating future denser/segmented configurations.
Figure 2: Layout of the ALPAQUITA surface array. Each square represents a 1 m 2 scintillating counter.
Figure 2: Layout of the ALPAQUITA surface array. Each square represents a 1 m 2 scintillating counter.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.