Skip to main content
QUICK REVIEW

[Paper Review] On-sky SiPM Performance Measurements for Millisecond to Sub-Microsecond Optical Source Variability Studies

Albert Wai Kit Lau, Mehdi Shafiee|arXiv (Cornell University)|Feb 1, 2020
Calibration and Measurement TechniquesEngineering22 references2 citations
TL;DR

This study evaluates silicon photomultiplier (SiPM) performance for ultra-fast optical variability detection using two SiPMs (S14520-3050VS and S14160-3050HS) mounted on the NUTTelA-TAO telescope. It demonstrates linear response to flux, measures dark current and sky background, and derives 5σ sensitivities of 14.7 and 15.2 G-band magnitudes for 200ms exposures, with a detection limit of 20 photons (6.1 mag) in 10 μs and 12 photons (fluence ~133 photons/m²) in 100 ns, limited by crosstalk.

ABSTRACT

As part of our Ultra-Fast Astronomy (UFA) program, we present initial measurements of silicon photomultiplier detector (SiPM) performance for application to measurement of variability of optical astronomical targets on millisecond and shorter time scales. We mounted two different SiPM detectors at the focal plane of the 0.7 meter Nazarbayev University Transient Telescope at the Assy-Turgen Astrophysical Observatory (NUTTelA-TAO), with no filter in front of the detector, and measured their performance. The $3mm imes3mm$ SiPM detectors had a field of view of $2.2716' imes2.2716'$ for each SiPM channel. During the nights of 28-29/10/2019, we measured sky background, bright stars, and an artificial source with a 100Hz flashing frequency. We compared detected SiPM counts with Gaia satellite G band flux values to show that our SiPM detectors have linear response. With our two SiPMs (models S14520-3050VS and S14160-3050HS), we measured a dark current of $\sim$130 and $\sim$85 kilo count per second (kcps), and a sky background of $\sim$191 and $\sim$203 kcps, respectively. We measured an intrinsic crosstalk of 10.34$\%$ and 10.52$\%$ for the two detectors, respectively. We derive a 5$\sigma$ sensitivity of 14.7 and 15.2 Gaia G-band magnitude for 200ms exposures, for the two detectors, respectively. We derive, for transient events in 10$\mu s$ time window, a sensitivity of 20 detected photons or 6.1 Gaia G-band magnitudes. For shorter timescales , e.g. 100ns, our detection limit is limited by crosstalk to 12 detected photons, which correspond to fluence of $\sim$133 photons per square meter within 100ns.

Motivation & Objective

  • To assess SiPM performance for detecting optical variability on millisecond and sub-microsecond timescales in astronomical sources.
  • To measure key detector parameters such as dark current, sky background, and crosstalk in a real on-sky environment.
  • To establish the 5σ sensitivity limits of SiPMs for transient events across different integration times.
  • To evaluate the impact of crosstalk on detection limits at ultra-short timescales (100 ns).

Proposed method

  • Mounted two SiPMs (S14520-3050VS and S14160-3050HS) at the focal plane of the 0.7m NUTTelA-TAO telescope without optical filters.
  • Measured sky background and flux from bright stars and an artificial 100 Hz flashing source during 28–29 October 2019.
  • Compared detected SiPM counts with Gaia G-band flux values to confirm linear response over the observed dynamic range.
  • Quantified dark current and sky background in kilo-counts per second (kcps) from on-sky measurements.
  • Measured intrinsic crosstalk using statistical analysis of SiPM pulse amplitudes.
  • Calculated 5σ sensitivity in G-band magnitude for 200ms exposures and photon detection limits for 10 μs and 100 ns integration windows.

Experimental results

Research questions

  • RQ1What is the linearity of SiPM response to optical flux over the G-band magnitude range observed?
  • RQ2What are the dark current and sky background levels for the two SiPM models under real sky conditions?
  • RQ3What is the intrinsic crosstalk level in the two SiPM detectors used in the study?
  • RQ4What is the 5σ detection sensitivity for transient events in 200ms exposures?
  • RQ5What is the minimum detectable number of photons in 10 μs and 100 ns time windows, and what fluence does it correspond to?

Key findings

  • The SiPMs exhibited linear response to flux, confirmed by comparison of detected counts with Gaia G-band magnitudes.
  • Dark current was measured at ~130 kcps for the S14520-3050VS and ~85 kcps for the S14160-3050HS.
  • Sky background levels were ~191 kcps and ~203 kcps for the two SiPMs, respectively.
  • Intrinsic crosstalk was 10.34% and 10.52% for the two detectors, respectively.
  • The 5σ sensitivity was 14.7 and 15.2 G-band magnitudes for 200ms exposures, respectively.
  • For 10 μs integration, the detection limit was 20 detected photons, corresponding to a fluence of ~133 photons per square meter in 100 ns, limited by crosstalk at 100 ns timescale.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.