This paper challenges Sinn (2017) by showing that electrical storage needs for high shares of variable wind and solar power are up to two orders of magnitude lower when optimizing for economic efficiency rather than relying on extreme corner solutions. Using a parsimonious optimization model that balances storage investment, renewable curtailment, and system costs, the authors find that storage is unlikely to limit the renewable energy transition, especially with broader sector integration and flexible demand.
The use of renewable energy sources is a major strategy to mitigate climate change. Yet Sinn (2017) argues that excessive electrical storage requirements limit the further expansion of variable wind and solar energy. We question, and alter, strong implicit assumptions of Sinn's approach and find that storage needs are considerably lower, up to two orders of magnitude. First, we move away from corner solutions by allowing for combinations of storage and renewable curtailment. Second, we specify a parsimonious optimization model that explicitly considers an economic efficiency perspective. We conclude that electrical storage is unlikely to limit the transition to renewable energy.
Motivation & Objective
- To challenge the conclusion that electrical storage limits the expansion of variable renewable energy sources, as argued by Sinn (2017).
- To address the strong implicit assumptions in Sinn’s model, particularly the exclusive use of corner solutions (no storage or no curtailment).
- To develop a more economically efficient optimization framework that balances storage capacity, renewable curtailment, and system costs.
- To assess how factors like geographical load smoothing, flexible demand, and sector integration (e.g., power-to-x) reduce storage requirements.
- To provide a more realistic and policy-relevant assessment of storage needs for high renewable electricity systems using open-source tools and data.
Proposed method
- Develops a parsimonious optimization model that minimizes total system cost, including investments in storage, renewable capacity, and curtailment.
- Explicitly models the trade-off between storage capacity and renewable curtailment, avoiding the extreme cases of either full curtailment or full storage use.
- Uses historical weather and demand data from Germany to simulate electricity supply and demand profiles under varying renewable shares.
- Incorporates spatial smoothing by modeling cross-regional load balancing across Germany and neighboring countries to reduce residual load variability.
- Analyzes the impact of flexible demand and power-to-x applications (e.g., hydrogen, electric heating, e-mobility) on reducing storage needs.
- Employs open-source tools and publicly available datasets to ensure transparency and reproducibility of results.
Experimental results
Research questions
- RQ1How do storage requirements for variable renewable energy change when moving from corner solutions to an economically efficient trade-off between storage and curtailment?
- RQ2To what extent do geographical load balancing and cross-border electricity market integration reduce the need for electrical storage?
- RQ3How do flexible demand and power-to-x applications (e.g., hydrogen production, electric heating) affect the required storage capacity for high renewable electricity shares?
- RQ4How sensitive are storage requirements to the choice of base year and input data quality in long-term simulations?
- RQ5What is the impact of different renewable generation profiles (e.g., offshore vs. onshore wind, solar PV) on system storage needs?
Key findings
- Storage requirements for a fully renewable electricity system in Germany are up to two orders of magnitude lower than estimated by Sinn (2017), when optimizing for economic efficiency rather than eliminating all curtailment.
- The optimal solution combines moderate storage capacity with a small share of renewable curtailment, significantly reducing the need for massive storage infrastructure.
- Geographical dispersion of wind and solar generation reduces residual load variability, lowering required storage capacity by smoothing supply and demand mismatches.
- Flexible demand and power-to-x applications such as hydrogen production or electric heating can further reduce storage needs by enabling time-shifting of electricity use.
- Offshore wind, with higher full-load hours (3,200 h) and lower variability (coefficient of variation 0.73), contributes more efficiently to system stability than onshore wind (1,600 h, CV 0.83).
- The study’s results are consistent with the broader literature and demonstrate that electrical storage is unlikely to be a binding constraint on the renewable energy transition.
Read this paper