Skip to main content
QUICK REVIEW

[Paper Review] One-Class SVM on siamese neural network latent space for Unsupervised Anomaly Detection on brain MRI White Matter Hyperintensities

Nicolas Pinon, Robin Trombetta|arXiv (Cornell University)|Apr 17, 2023
Brain Tumor Detection and ClassificationNeuroscience3 citations
TL;DR

This paper proposes a novel unsupervised anomaly detection method for brain MRI white matter hyperintensities (WMH) using a siamese auto-encoder to learn a compact latent representation from normal T1 and FLAIR images, followed by patient-specific One-Class SVM classification in the latent space. The approach achieves performance on par with state-of-the-art models on the WMH challenge dataset, demonstrating strong sensitivity to subtle lesions while maintaining low false positives through CSF masking.

ABSTRACT

Anomaly detection remains a challenging task in neuroimaging when little to no supervision is available and when lesions can be very small or with subtle contrast. Patch-based representation learning has shown powerful representation capacities when applied to industrial or medical imaging and outlier detection methods have been applied successfully to these images. In this work, we propose an unsupervised anomaly detection (UAD) method based on a latent space constructed by a siamese patch-based auto-encoder and perform the outlier detection with a One-Class SVM training paradigm tailored to the lesion detection task in multi-modality neuroimaging. We evaluate performances of this model on a public database, the White Matter Hyperintensities (WMH) challenge and show in par performance with the two best performing state-of-the-art methods reported so far.

Motivation & Objective

  • Address the challenge of detecting subtle, low-contrast white matter hyperintensities in brain MRI when labeled data is scarce or unavailable.
  • Overcome limitations of reconstruction-based autoencoders in detecting very small or subtle lesions by leveraging discriminative outlier detection in a learned latent space.
  • Provide a fair comparison with state-of-the-art models by training and evaluating on the same public WMH challenge dataset using identical metrics and protocols.
  • Investigate the impact of data distribution shifts across clinical centers on model generalization and performance.

Proposed method

  • Train a siamese auto-encoder (SAE) on patches extracted from T1 and FLAIR MRI scans of healthy controls, using shared weights to learn a shared latent representation.
  • Extract latent features z from the SAE encoder for each patch, forming a representation space that captures local, multi-modal image patterns.
  • For each patient, fine-tune a One-Class SVM (OC-SVM) on a subset of their own latent representations to learn the normality boundary specific to that individual.
  • Perform inference on the full brain by computing OC-SVM decision scores for all patches, with higher scores indicating potential anomalies.
  • Apply a post-processing step using a CSF mask to suppress false positives in ventricles and cerebrospinal fluid regions.
  • Use a multi-center dataset (Amsterdam, Singapore, Utrecht) to evaluate robustness and generalization across scanner and acquisition differences.

Experimental results

Research questions

  • RQ1Can a siamese auto-encoder combined with patient-specific One-Class SVM achieve competitive performance in unsupervised WMH detection compared to state-of-the-art generative models?
  • RQ2Does learning a discriminative normality boundary in the latent space of a patch-based auto-encoder improve detection of subtle, low-contrast WMH lesions compared to reconstruction error-based methods?
  • RQ3How does model performance vary across different clinical centers with potential data distribution shifts, especially in FLAIR imaging?
  • RQ4To what extent does post-processing with a CSF mask reduce false positives without significantly compromising sensitivity?

Key findings

  • The SAE+OC-SVM model achieved performance on par with the two best-performing state-of-the-art methods on the WMH challenge, with a PRO AUC of 0.827, indicating strong outlier detection capability.
  • Tuning the OC-SVM per patient significantly improved performance compared to a single global OC-SVM, highlighting the benefit of patient-specific normality modeling.
  • Applying a CSF mask reduced the false positive rate substantially, with overall performance improving on all metrics when the mask was used, despite a slight drop in sensitivity.
  • All models, including the proposed method, showed decreased performance on the Utrecht dataset, likely due to greater distribution shift between controls and test data, especially in FLAIR sequences.
  • The model's performance was lower on datasets with lower mean lesional volume (e.g., Amsterdam: 13.5k mm³), suggesting sensitivity limitations in low-burden cases.
  • The study demonstrates that discriminative OC-SVM in a learned latent space can match generative models like VQ-VAE+Transformer, even when trained on a smaller, more homogeneous control set.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.