TL;DR

This paper proposes a fully unsupervised one-sample diffusion model (OSDM) in the projection domain for low-dose CT reconstruction, leveraging Hankel matrix formulation to extract rich priors from a single sinogram and combining score-based generative modeling with data consistency and total variation regularization. The method achieves high-quality image reconstruction approaching normal-dose images with reduced artifacts.

ABSTRACT

Low-dose computed tomography (CT) plays a significant role in reducing the radiation risk in clinical applications. However, lowering the radiation dose will significantly degrade the image quality. With the rapid development and wide application of deep learning, it has brought new directions for the development of low-dose CT imaging algorithms. Therefore, we propose a fully unsupervised one sample diffusion model (OSDM)in projection domain for low-dose CT reconstruction. To extract sufficient prior information from single sample, the Hankel matrix formulation is employed. Besides, the penalized weighted least-squares and total variation are introduced to achieve superior image quality. Specifically, we first train a score-based generative model on one sinogram by extracting a great number of tensors from the structural-Hankel matrix as the network input to capture prior distribution. Then, at the inference stage, the stochastic differential equation solver and data consistency step are performed iteratively to obtain the sinogram data. Finally, the final image is obtained through the filtered back-projection algorithm. The reconstructed results are approaching to the normal-dose counterparts. The results prove that OSDM is practical and effective model for reducing the artifacts and preserving the image quality.

Motivation & Objective

  • To address the challenge of low-dose CT image reconstruction with minimal supervision, particularly when only one normal-dose sinogram is available.
  • To develop a fully unsupervised method that can learn meaningful image priors from a single low-dose CT projection dataset.
  • To improve image quality by reducing artifacts and preserving fine structures in low-dose CT reconstructions.
  • To enable effective reconstruction without requiring large-scale paired training data, which is often impractical in clinical settings.

Proposed method

  • The method employs a Hankel matrix formulation to extract a large number of tensors from a single sinogram, enabling rich prior learning from limited data.
  • A score-based generative model is trained on these tensors to learn the underlying prior distribution of the projection data.
  • At inference, a stochastic differential equation solver iteratively denoises the low-dose sinogram while enforcing data consistency with the measured projection data.
  • Total variation and penalized weighted least-squares regularization are integrated to enhance reconstruction fidelity and reduce noise.
  • The final image is reconstructed using filtered back-projection after obtaining the refined sinogram.
  • The entire framework operates entirely in the projection domain, avoiding the need for image-domain optimization or paired data.

Experimental results

Research questions

  • RQ1Can a single-sinogram diffusion model effectively learn image priors without requiring large-scale paired training data in low-dose CT?
  • RQ2How well can a score-based generative model trained on a single normal-dose sinogram reconstruct high-quality images from low-dose projections?
  • RQ3To what extent does the integration of data consistency and total variation improve reconstruction quality in the projection domain?
  • RQ4Can the proposed one-sample diffusion model outperform existing unsupervised or weakly supervised low-dose CT reconstruction methods?

Key findings

  • The proposed OSDM achieves reconstruction quality that closely approaches that of normal-dose CT images, significantly reducing streaking and noise artifacts.
  • The use of Hankel matrix-based tensor extraction enables effective prior learning from a single sinogram, enhancing model generalization.
  • The integration of data consistency and total variation regularization improves structural preservation and noise suppression in the reconstructed images.
  • The method demonstrates strong performance in both qualitative and quantitative evaluations, with results competitive with state-of-the-art methods despite using only one sample for training.