[Paper Review] Open-source neuronavigation for multimodal non-invasive brain stimulation using 3D Slicer
This paper presents an open-source, customizable neuronavigation system for multimodal non-invasive brain stimulation using 3D Slicer and the Plus Toolkit, enabling real-time tracking of transducer and stylus positions relative to patient-specific MRI. It achieves 0.93 mm isotropic spatial accuracy and provides pre-configured scene files and a detailed manual to accelerate adoption and ensure reproducibility in clinical and research settings.
In recent years, non-invasive neuro-modulation methods such as Focused Ultrasound (FUS) have gained popularity. The aim of this work is to introduce the use of existing open-source technology for surgical navigation to the field of multimodal non-invasive brain stimulation. Unlike homegrown and commercial systems, the use of well-documented, well maintained, and freely available open-source components minimizes the learning curve, maximizes technology transfer outcome, and fosters reproducible science for complex, guided neuromodulation systems. The described system significantly lowers the entry bar to clinical research and experimentation in the field of non-invasive brain stimulation. Our contribution is two-fold. First, a high-level overview of the components of the descried system is given in this manuscript. Second, all files are made available online, with a comprehensive step-by-step manual, quickly allowing researchers to build a custom system. A spatial accuracy of 0.93 mm was found through validation using a robotic positioning system.
Motivation & Objective
- To address the lack of accessible, reproducible, and customizable neuronavigation systems for non-invasive brain stimulation (NIBS) in research.
- To reduce the technical and learning barriers for researchers developing custom NIBS systems, especially for emerging modalities like transcranial focused ultrasound (tFUS).
- To promote reproducible science by replacing proprietary or homegrown systems with well-documented, open-source software components.
- To enable rapid deployment of neuronavigation systems through pre-configured 3D Slicer scenes and a comprehensive step-by-step manual.
- To validate spatial accuracy of a low-cost, open-source navigation setup suitable for clinical and experimental neuromodulation.
Proposed method
- The system integrates 3D Slicer (v4.8.0) as the central software framework for image visualization and processing, and the Plus Toolkit (v2.6.0) for real-time optical tracking of multiple tools.
- Optical tracking is performed using an NDI Polaris Vicra camera to monitor the position of fiducial markers on the patient’s head, the transducer applicator, and a pointer stylus in real time.
- Fiducial-based registration aligns the patient’s head with the pre-acquired MRI volume, with re-registration possible without repeat MRI scans.
- Transform hierarchies in 3D Slicer map physical tool positions to the RAS (right-anterior-superior) coordinate system via OpenIGTLink communication.
- A custom reference marker and stylus are fabricated for validation, and all system components are configured using open-source, documented software.
- The system supports multimodal stimulation by rendering the Spatial Peak Intensity Location (SPIL) of the transducer in real time over the MRI volume.
Experimental results
Research questions
- RQ1Can an open-source, modular neuronavigation system be built using existing, well-maintained software tools to support non-invasive brain stimulation research?
- RQ2What is the spatial accuracy of a low-cost, open-source neuronavigation system using custom fiducial markers and optical tracking?
- RQ3To what extent can pre-configured scene files and detailed documentation reduce setup time and improve reproducibility in neuromodulation experiments?
- RQ4How does the performance of a custom-built, open-source system compare to commercial alternatives in terms of accuracy and usability?
- RQ5Can this system be effectively adapted for emerging non-invasive stimulation modalities such as transcranial focused ultrasound (tFUS)?
Key findings
- The system achieves a spatial accuracy of 0.93 mm (SD 0.74 mm) when validated using a robotic positioning system with a 20 x 20 x 20 mm cube.
- The validation confirms that custom-made fiducial markers and tracking tools are sufficiently accurate for typical non-invasive brain stimulation procedures, including tFUS.
- The pre-configured 3D Slicer scene and Plus Toolkit configuration files are publicly available on GitHub, enabling rapid deployment with minimal technical expertise.
- The detailed manual guides users through all fiducial registration steps, significantly reducing the learning curve for new users.
- The system enables real-time visualization of the transducer’s Spatial Peak Intensity Location (SPIL) overlaid on patient-specific MRI, supporting precise targeting.
- The use of open-source components ensures long-term maintainability, technology transfer, and reproducibility across research teams.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.