Skip to main content
QUICK REVIEW

[Paper Review] Optimal Battery Energy Storage Placement for Transient Voltage Stability Enhancement

Yongli Zhu, Chengxi Liu|arXiv (Cornell University)|Mar 5, 2019
Microgrid Control and OptimizationEngineering18 references3 citations
TL;DR

This paper proposes an optimal placement strategy for multiple Battery Energy Storage Systems (BESS) to enhance transient voltage stability in power systems using a Cross-Entropy (CE) optimization method. The approach models nonlinear dynamics via simulation-based analysis, maximizes a voltage stability index aligned with grid codes, and demonstrates superior convergence and solution quality compared to PSO on the New England 39-Bus system, effectively mitigating voltage instability.

ABSTRACT

A placement problem for multiple Battery Energy Storage System (BESS) units is formulated towards power system transient voltage stability enhancement in this paper. The problem is solved by the Cross-Entropy (CE) optimization method. A simulation-based approach is adopted to incorporate higher-order dynamics and nonlinearities of generators and loads. The objective is to maximize the voltage stability index, which is set up based on certain grid-codes. Formulations of the optimization problem are then discussed. Finally, the proposed approach is implemented in MATLAB/DIgSILENT and tested on the New England 39-Bus system. Results indicate that installing BESS units at the optimized location can alleviate transient voltage instability issue compared with the original system with no BESS. The CE placement algorithm is also compared with the classic PSO (Particle Swarm Optimization) method, and its superiority is demonstrated in terms of fewer iterations for convergence with better solution qualities.

Motivation & Objective

  • To address transient voltage instability in power systems caused by large disturbances.
  • To determine optimal locations for multiple Battery Energy Storage Systems (BESS) to enhance system stability.
  • To formulate a placement problem that maximizes a voltage stability index based on grid-code requirements.
  • To develop and validate a simulation-based optimization framework incorporating nonlinear generator and load dynamics.
  • To compare the performance of the Cross-Entropy method against Particle Swarm Optimization (PSO) in terms of convergence speed and solution quality.

Proposed method

  • The optimization problem is formulated to maximize a voltage stability index derived from system operating conditions and grid-code compliance.
  • A simulation-based approach is used to model higher-order dynamics and nonlinearities of synchronous generators and load models.
  • The Cross-Entropy (CE) method is applied to solve the combinatorial optimization problem for BESS placement.
  • The method iteratively updates a probability distribution over candidate locations using elite solutions from simulation evaluations.
  • MATLAB/DIgSILENT co-simulation environment is used to model the New England 39-Bus system and evaluate transient responses.
  • The CE algorithm is benchmarked against PSO using identical simulation conditions and convergence criteria.

Experimental results

Research questions

  • RQ1Where should multiple BESS units be optimally placed to maximize transient voltage stability in a bulk power system?
  • RQ2How does the Cross-Entropy method compare to PSO in solving the BESS placement problem in terms of convergence speed and solution quality?
  • RQ3To what extent can BESS placement mitigate transient voltage instability under large disturbances?
  • RQ4How do nonlinear generator and load dynamics affect the optimal placement solution?
  • RQ5What is the impact of the voltage stability index formulation on the optimization outcome and system performance?

Key findings

  • The proposed CE-based BESS placement method achieved faster convergence with better solution quality compared to PSO, requiring fewer iterations to reach optimal or near-optimal solutions.
  • Installation of BESS units at the optimized locations significantly improved transient voltage stability, reducing voltage dips and improving recovery after fault clearing.
  • The simulation results demonstrated that the voltage stability index increased substantially in the optimized system compared to the original system without BESS.
  • The CE method showed robustness in handling the nonlinearity and complexity of power system dynamics, outperforming PSO in both convergence speed and final solution accuracy.
  • The co-simulation framework in MATLAB/DIgSILENT successfully captured the dynamic interactions between BESS and the power system, validating the practical feasibility of the approach.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.