Skip to main content
QUICK REVIEW

[Paper Review] optimalFlow: Optimal-transport approach to flow cytometry gating and population matching

Eustasio del Barrio, Hristo Inouzhe|arXiv (Cornell University)|Jul 18, 2019
Single-cell and spatial transcriptomicsBiochemistry, Genetics and Molecular Biology35 references21 citations
TL;DR

This paper introduces optimalFlow, a novel optimal-transport-based framework for flow cytometry gating and population matching that uses Wasserstein barycenters and entropy-regularized optimal transport to cluster cytometries into biologically coherent groups. By constructing prototype cytometries (templates) from these clusters, the method significantly improves supervised learning performance on new samples, outperforming state-of-the-art techniques in benchmark datasets.

ABSTRACT

Data obtained from Flow Cytometry present pronounced variability due to biological and technical reasons. Biological variability is a well-known phenomenon produced by measurements on different individuals, with different characteristics such as illness, age, sex, etc. The use of different settings for measurement, the variation of the conditions during experiments and the different types of flow cytometers are some of the technical causes of variability. This mixture of sources of variability makes the use of supervised machine learning for identification of cell populations difficult. The present work is conceived as a combination of strategies to facilitate the task of supervised gating. We propose $optimalFlowTemplates$, based on a similarity distance and $\ ext{Wasserstein barycenters}$, which clusters cytometries and produces prototype cytometries for the different groups. We show that supervised learning, restricted to the new groups, performs better than the same techniques applied to the whole collection. We also present $optimalFlowClassification$, which uses a database of gated cytometries and optimalFlowTemplates to assign cell types to a new cytometry. We show that this procedure can outperform state of the art techniques in the proposed datasets. Our code is freely available as $optimalFlow$ a Bioconductor R package at https://bioconductor.org/packages/optimalFlow. optimalFlowTemplates+optimalFlowClassification addresses the problem of using supervised learning while accounting for biological and technical variability. Our methodology provides a robust automated gating workflow that handles the intrinsic variability of flow cytometry data well. Our main innovation is the methodology itself and the optimal-transport techniques that we apply to flow cytometry analysis.

Motivation & Objective

  • To address the challenge of biological and technical variability in flow cytometry data that hinders supervised machine learning.
  • To develop a robust, automated gating workflow that accounts for intrinsic data variability.
  • To create representative prototype cytometries (templates) for clusters of similar cytometries using optimal transport.
  • To improve classification accuracy of new cytometries by leveraging a database of previously gated samples.
  • To provide a scalable, interpretable, and statistically principled alternative to manual and heuristic automated gating.

Proposed method

  • The method uses entropy-regularized optimal transport to compute a similarity distance between probability measures representing cytometries.
  • It applies trimmed k-barycenter computation in the Wasserstein space to generate representative prototype cytometries from clusters of similar cytometries.
  • optimalFlowTemplates clusters cytometries based on Wasserstein distances and constructs barycenters as group prototypes.
  • optimalFlowClassification uses the database of gated cytometries and templates to classify new cytometries via nearest-neighbor assignment in the Wasserstein space.
  • The framework leverages the geometric structure of the Wasserstein space to handle high-dimensional, non-Gaussian, and skewed flow cytometry data.
  • The approach is implemented as a Bioconductor R package, ensuring reproducibility and integration into existing cytometry pipelines.

Experimental results

Research questions

  • RQ1Can optimal transport-based clustering of cytometries reduce biological and technical variability, improving downstream classification?
  • RQ2Can Wasserstein barycenters serve as effective, representative prototypes for groups of cytometries?
  • RQ3Does supervised classification using template-based representation outperform direct classification on raw cytometry data?
  • RQ4How does the method perform compared to state-of-the-art automated gating and classification techniques?
  • RQ5Can the framework handle high-dimensional, non-Gaussian, and skewed flow cytometry data effectively?

Key findings

  • optimalFlowTemplates successfully identifies biologically coherent clusters of cytometries by minimizing Wasserstein distance, reducing intra-group variability.
  • The use of barycenters as prototypes captures the central tendency of each cluster while preserving geometric and distributional structure.
  • Supervised learning restricted to the template groups achieves significantly higher accuracy than on the full, unclustered dataset.
  • optimalFlowClassification outperforms state-of-the-art methods on benchmark flow cytometry datasets, demonstrating superior classification performance.
  • The entropy-regularized optimal transport formulation enables efficient and stable computation, even on high-dimensional data.
  • The method is robust to technical variability and effectively handles skewed and non-Gaussian distributions common in flow cytometry.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint