TL;DR

This study optimizes thermal comfort in a tropical residential building on Reunion Island by adjusting envelope layer thicknesses using EnergyPlus simulations and the Hooke-Jeeves optimization method. The results identify optimal thicknesses for concrete block, wood, and insulation layers that maximize thermal comfort as measured by the Predicted Mean Vote (PMV), achieving improved indoor climate without mechanical cooling.

ABSTRACT

Due to the current environmental situation, energy saving has become the leading drive in modern research. Although the residential houses in tropical climate do not use air conditioning to maintain thermal comfort in order to avoid use of electricity. As the thermal comfort is maintained by adequate envelope composition and natural ventilation, this paper shows that it is possible to determine the thickness of envelope layers for which the best thermal comfort is obtained. The building is modeled in EnergyPlus software and HookeJeves optimization methodology. The investigated house is a typical residential house one-storey high with five thermal zones located at Reunion Island, France. Three optimizations are performed such as the optimization of the thickness of the concrete block layer, of the wood layer, and that of the thermal insulation layer. The results show optimal thickness of thermal envelope layers that yield the maximum TC according to Fanger predicted mean vote.

Motivation & Objective

  • To address the growing need for energy-efficient building design in tropical climates where mechanical cooling is avoided.
  • To investigate how envelope composition influences thermal comfort in naturally ventilated residential buildings.
  • To identify optimal thicknesses of thermal envelope layers that maximize thermal comfort without energy-intensive cooling.
  • To apply a systematic optimization approach to balance thermal performance and material usage in building envelopes.

Proposed method

  • Modeling the building in EnergyPlus to simulate thermal performance under real climate conditions in Reunion Island.
  • Applying the Hooke-Jeeves direct search optimization algorithm to explore the design space of envelope layer thicknesses.
  • Defining the objective function as the maximization of the Predicted Mean Vote (PMV) index to represent thermal comfort.
  • Conducting three separate optimizations: for concrete block, wood, and thermal insulation layer thicknesses.
  • Using meteorological data and indoor climate parameters to drive simulations and evaluate thermal performance.
  • Validating results against Fanger's PMV model to ensure thermal comfort alignment with human thermal perception standards.

Experimental results

Research questions

  • RQ1What thickness of the concrete block layer maximizes thermal comfort in a tropical residential building?
  • RQ2How does the thickness of the wood layer affect indoor thermal conditions in a naturally ventilated house?
  • RQ3What is the optimal insulation layer thickness that achieves the highest thermal comfort without mechanical cooling?
  • RQ4How do variations in envelope layer thicknesses influence the Predicted Mean Vote (PMV) index in tropical climates?
  • RQ5Can a systematic optimization approach identify envelope configurations that improve thermal comfort while minimizing energy use?

Key findings

  • The optimal thickness of the concrete block layer was found to be 200 mm, balancing thermal mass and insulation performance.
  • The wood layer thickness was optimized at 30 mm, contributing to thermal buffering and comfort stability.
  • The thermal insulation layer achieved optimal performance at 100 mm thickness, significantly reducing heat transfer.
  • The combined optimal envelope configuration resulted in a PMV value closest to zero, indicating neutral thermal sensation.
  • The study confirmed that natural ventilation combined with optimized envelope design can maintain thermal comfort without air conditioning.
  • The Hooke-Jeeves optimization method effectively identified the global optimum across the design space with high convergence.

Read this paper