[Paper Review] Path Integral Sampler: a stochastic control approach for sampling
Path Integral Sampler (PIS) is a novel stochastic control-based sampling algorithm that generates samples from unnormalized target densities by solving the Schrödinger bridge problem via a neural network-controlled SDE. It enables end-to-end training with free-form architecture, provides theoretical Wasserstein distance guarantees under sub-optimal control, and uses path integral-based importance weights to correct bias, outperforming existing methods in sample quality and efficiency.
We present Path Integral Sampler~(PIS), a novel algorithm to draw samples from unnormalized probability density functions. The PIS is built on the Schrödinger bridge problem which aims to recover the most likely evolution of a diffusion process given its initial distribution and terminal distribution. The PIS draws samples from the initial distribution and then propagates the samples through the Schrödinger bridge to reach the terminal distribution. Applying the Girsanov theorem, with a simple prior diffusion, we formulate the PIS as a stochastic optimal control problem whose running cost is the control energy and terminal cost is chosen according to the target distribution. By modeling the control as a neural network, we establish a sampling algorithm that can be trained end-to-end. We provide theoretical justification of the sampling quality of PIS in terms of Wasserstein distance when sub-optimal control is used. Moreover, the path integrals theory is used to compute importance weights of the samples to compensate for the bias induced by the sub-optimality of the controller and time-discretization. We experimentally demonstrate the advantages of PIS compared with other start-of-the-art sampling methods on a variety of tasks.
Motivation & Objective
- To develop a flexible, end-to-end trainable sampling method for unnormalized probability densities without requiring explicit density models.
- To leverage the Schrödinger bridge framework to formulate sampling as a stochastic optimal control problem with a terminal cost tied to the target distribution.
- To enable high-quality sampling with fewer steps than traditional MCMC while providing theoretical performance bounds.
- To correct for sub-optimal control and time-discretization bias using path integral theory to compute importance weights.
- To overcome limitations of variational inference (explicit density constraints) and MCMC (slow mixing, hard-to-train proposals) through an implicit, scalable, and differentiable sampling framework.
Proposed method
- Formulate the sampling problem as a stochastic optimal control problem where the running cost is control energy and the terminal cost is derived from the target density.
- Model the control policy using a neural network to enable free-form architecture design and end-to-end training.
- Use the Girsanov theorem to reweight the SDE dynamics and connect the initial Wiener process to the target distribution via controlled diffusion.
- Apply path integral theory to compute importance weights for samples, compensating for sub-optimality and discretization errors in the control policy.
- Train the controller via a KL divergence objective between the terminal distribution of the controlled SDE and the target measure.
- Use Euler-Maruyama SDE integration without adjoint for stability, especially in low dimensions, and Reversible Heun when memory is constrained.
Experimental results
Research questions
- RQ1Can a stochastic control framework based on the Schrödinger bridge problem be used to design a flexible, end-to-end trainable sampling algorithm for unnormalized densities?
- RQ2How can sub-optimal control policies be corrected to ensure asymptotically unbiased sampling?
- RQ3What theoretical performance guarantees can be provided for sampling quality when using sub-optimal controllers?
- RQ4How does the choice of time horizon T and time step size Δt affect training stability and sample quality?
- RQ5Can PIS outperform state-of-the-art methods like MCMC and normalizing flows in sample quality and efficiency on diverse tasks?
Key findings
- PIS provides theoretical guarantees on sampling quality in terms of Wasserstein distance even when using sub-optimal control policies.
- The use of path integral-based importance weights effectively corrects for bias introduced by sub-optimal control and time discretization.
- Larger time horizons T improve training stability and mode coverage, while smaller T leads to high-Lipschitz control policies that are harder to train.
- Smaller time steps Δt reduce discretization error and improve sample quality, especially when combined with higher integration steps.
- PIS outperforms baseline methods in sample quality and efficiency on tasks including Gaussian mixtures, funnel distributions, and real-world datasets like MNIST and CIFAR-10.
- Training with batch normalization and gradient clipping improves stability, and Euler-Maruyama without adjoint integration is more reliable than adjoint-based methods in practice.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.