[Paper Review] Performance of Michigan sMDT Prototype Chambers for the HL-LHC ATLAS Muon Detector Upgrade
This paper evaluates the performance of two prototype small-diameter Monitored Drift Tube (sMDT) chambers developed at the University of Michigan for the HL-LHC ATLAS muon detector upgrade. Using cosmic-ray muons, the chambers achieved a tracking resolution of 101.8±7.8 µm and 103.7±8.1 µm, meeting the design goal of 106 µm, with a further improvement to 83.4±7.8 µm using high-gain electronics. An average efficiency of 98.5±0.2% was measured, confirming the chambers' readiness for mass production.
A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7$\pm8.1$ extmu m was measured for one chamber and 101.8$\pm$7.8 extmu m for the other, compared with a design resolution of 106 extmu m. A further tracking resolution improvement to 83.4$\pm$7.8 extmu m was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5$\pm$0.2)\% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.
Motivation & Objective
- To validate the tracking resolution and efficiency of prototype sMDT chambers for the HL-LHC ATLAS muon spectrometer upgrade.
- To assess whether the sMDT chambers meet the design specifications of 106 µm single-hit resolution and 94% layer efficiency.
- To develop and apply a robust methodology for measuring resolution and efficiency, including r(t) calibration and multiple scattering deconvolution.
- To demonstrate the feasibility of using high-gain readout electronics (ASD-2) to improve resolution beyond the design target.
Proposed method
- In-situ r(t) calibration using a linearized least-squares procedure to determine the time-to-space transfer function for each drift tube.
- Implementation of a Δt₀ parameter to correct for trigger timing smearing caused by large scintillator trigger systems.
- Use of Geant4 simulations to model the cosmic-ray muon spectrum and simulate multiple Coulomb scattering effects.
- Deconvolution of multiple scattering effects by fitting simulated scattering distributions to measured resolution data in radial bins.
- Iterative fitting of residual vs. radius curves using second-order polynomials to model position-dependent resolution uncertainty.
- Systematic uncertainty estimation through error propagation across calibration, track fitting, signal timing, and simulation components.
Experimental results
Research questions
- RQ1Does the prototype sMDT chamber achieve the target tracking resolution of 106 µm under cosmic-ray conditions?
- RQ2How does the addition of high-gain ASD-2 electronics affect the measured tracking resolution?
- RQ3What is the intrinsic hit efficiency of the sMDT chambers, and how does it compare to the design goal of 94%?
- RQ4To what extent do multiple Coulomb scattering and signal propagation time contribute to resolution degradation?
- RQ5How do systematic uncertainties—especially from r(t) calibration and soft-electron components—affect the final resolution and efficiency measurements?
Key findings
- The prototype sMDT chambers achieved a single-hit tracking resolution of 103.7±8.1 µm for the BMG chamber and 101.8±7.8 µm for the BIS chamber, both within the design target of 106 µm.
- With high-gain ASD-2 electronics, the BIS chamber resolution improved to 83.4±7.8 µm, significantly exceeding the design specification.
- The measured hit efficiency was (98.5±0.2)% for both chambers, indicating excellent performance across all layers and tubes.
- The primary source of inefficiency was identified as the 0.9 mm gap between active gas volumes (two 0.4 mm tube walls and 0.1 mm spacing), with the tube wall region contributing most of the remaining inefficiency.
- Systematic uncertainties were dominated by track fitting (5.5 µm), statistical fluctuations (3.5 µm), and signal propagation time (2.2 µm), with total resolution uncertainty of 8.1 µm and 7.8 µm for the two chambers.
- The deconvolution method successfully corrected for multiple scattering, enabling accurate resolution measurement under realistic muon momentum conditions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.