Skip to main content
QUICK REVIEW

[Paper Review] Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) on-sky demonstration with MagAO-X

Elena Tonucci, Sebastiaan Haffert|arXiv (Cornell University)|Feb 26, 2026
Adaptive optics and wavefront sensingPhysics and Astronomy0 citations
TL;DR

This paper reports the first on-sky characterization of PIAACMC contrast and inner working angle using MagAO-X, including sub-micron NIR demonstrations and laboratory validation with internal sources.

ABSTRACT

Advancing the technological development of small inner working angle (IWA) coronagraphs is essential to enabling high-contrast imaging of temperate exoplanets with future extremely large telescopes. The PIAACMC has been shown to closely approach the theoretical limit for coronagraphic throughput but its performance has not been fully characterised on-sky. This study serves as the first on-sky characterisation of contrast and IWA performance of the PIAACMC and its first technological demonstration at sub-micron wavelengths. We designed and manufactured phase-shifting focal plane masks optimised for two cases, a narrowband 875 filter (875nm, 3% band) and a broadband z' filter (908nm, 14% band). We tested the coronagraphs both with an internal source and on-sky using MagAOX, the extreme adaptive optics instrument for the Magellan Clay 6.5 m telescope at Las Campanas Observatory. We show good recovery of the off-axis light's PSF shape within 92% and 97% depending on the separation when aligning the inverse set of PIAA lenses. We demonstrate sub-lambda/D IWAs of about 0.74 lambda/D in 875 and 0.76 lambda/D in z'. We reach average raw contrasts within 1 and 5 lambda/D with the internal source of about 1.6e-3 in 875 and 1.3e-3 in z'. These are mainly limited by the focal plane mask manufacturing errors, jitter, and residual quasi-static speckles in MagAO-X. We also show on-sky average raw contrasts within 1 and 5 lambda/D of about 1.4e-2 in 875 and 7.8e-3 in z'. These are likely limited by wavefront control, low-order aberrations, and poor observing conditions. Future work will improve the design and manufacturing processes of the focal plane masks to improve robustness and reach deeper contrast, as well as integrate focal plane wavefront control for non-common path aberrations correction.

Motivation & Objective

  • Motivate the development of high-throughput, small IWA coronagraphs for future ELTs and temperate exoplanet imaging.
  • Demonstrate and characterize PIAACMC performance on-sky and in the lab at sub-micron wavelengths.
  • Design, manufacture, and test PIAACMC components (PIAA lenses and focal plane masks) for MagAO-X.
  • Assess limitations from manufacturing errors, jitter, and quasi-static speckles on contrast.
  • Discuss pathways to improve focal plane masks and integrate wavefront control for non-common path aberrations.

Proposed method

  • Design forward and inverse PIAA lens sets and a phase-shifting focal plane mask optimized for two filters (875 nm narrowband and 908 nm z’ broadband).
  • Manufacture PIAA lenses with CaF2 and sub-20 nm RMS surface errors; produce focal plane masks via two-photon polymerisation; fabricate a reflective Lyot stop for LOWFS integration.
  • Use an end-to-end physical optics model (HCIPy) to optimize mask thicknesses and Lyot stop geometry for 0.75 λ/D FPM radius.
  • Characterize performance with MagAO-X in lab mode (internal source) and on-sky, evaluating throughput, contrast, and IWA.
  • Compare designed versus manufactured masks by incorporating measured height maps into end-to-end simulations to assess expected versus measured performance.
  • Assess chromaticity effects of phase masks and potential mitigation strategies in the optimization.

Experimental results

Research questions

  • RQ1What is the on-sky contrast performance of PIAACMC with MagAO-X at sub-micron wavelengths?
  • RQ2What is the achieved inner working angle (IWA) and throughput for the designed PIAACMC on the MagAO-X system?
  • RQ3How do manufacturing tolerances and system jitter/NCPAs limit PIAACMC performance?
  • RQ4Can the PIAACMC achieve sub-diffraction-limited IWA and near-diffraction-limited imaging in lab and on-sky conditions?
  • RQ5What improvements are needed to robustly reach deeper contrasts in future implementations?

Key findings

  • On-sky average raw contrasts within 1 and 5 λ/D of about 1.4×10^-2 (875 nm) and 7.8×10^-3 (z’ band) respectively, likely limited by wavefront control and observing conditions.
  • Laboratory results show sub-λ/D IWAs of ~0.74–0.76 λ/D with the 875 and z’ filters, and raw contrasts of ~1.6×10^-3 (875) and ~1.3×10^-3 (z’) within 1–5 λ/D, limited by manufacturing errors, jitter, and residual quasi-static speckles.
  • Manufacturing tolerances (mask height RMSE ~40–60 nm, corresponding surface deviations ~100 nm) degrade null depth; simulations suggest aiming for ~5 nm RMSE to reach design performance.
  • Chromaticity of the phase-shifting focal plane mask reduces performance away from the design wavelength; narrower bands yield better performance, and optimization can be adjusted to mitigate this.
  • End-to-end simulations incorporating measured mask heights predict lab performance: ~1.6×10^-3 (875) and ~1.4×10^-3 (z’) within 1–5 λ/D with printed masks and MagAO-X perturbations.
  • The study confirms PIAACMC’s on-sky viability at sub-micron wavelengths and outlines manufacturing and control-path improvements for deeper contrasts.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.