[Paper Review] Physics Behind Precision
This paper summarizes key discussions from the FCC-ee mini-workshop on precision physics, focusing on electroweak and top quark measurements at future $e^+e^-$ colliders. It proposes optimized energy scan strategies for measuring the W boson mass and width with sub-MeV precision, achieving projected uncertainties of $\Delta m_{\rm W} = 0.41$ MeV and $\Delta \Gamma_{\rm W} = 1.10$ MeV using a two-point scan at 157.5 GeV and 162.3 GeV with 45% luminosity at the lower energy point.
This document provides a writeup of contributions to the FCC-ee mini-workshop on "Physics behind precision" held at CERN, on 2-3 February 2016.
Motivation & Objective
- To assess the physics reach of FCC-ee in precision electroweak and top quark measurements compared to existing and future colliders.
- To evaluate the sensitivity of precision measurements to new physics beyond the Standard Model, particularly in scenarios like composite Higgs and FCNC single top processes.
- To determine optimal data-taking configurations for measuring the W boson mass and width using energy scans near the $WW$ threshold.
- To guide theoretical developments by ensuring that theory uncertainties remain at the same level as experimental uncertainties in high-precision measurements.
- To integrate findings into the FCC-ee Conceptual Design Report, advancing the roadmap for future $e^+e^-$ collider physics.
Proposed method
- Conducting a 3D scan of energy points $E_1$ and $E_2$ near the $WW$ threshold and luminosity fractions $f$ to minimize combined uncertainties on $m_{\rm W}$ and $\Gamma_{\rm W}$.
- Using linearized error propagation via partial derivatives: $\Delta\sigma_i = \frac{d\sigma_i}{dm}\Delta m + \frac{d\sigma_i}{d\Gamma}\Delta\Gamma = a_i\Delta m + b_i\Delta\Gamma$.
- Deriving combined uncertainties through matrix inversion: $\Delta m = \frac{ -b_2\Delta\sigma_1 + b_1\Delta\sigma_2 }{a_2b_1 - a_1b_2 }$, $\Delta\Gamma = \frac{ a_2\Delta\sigma_1 - a_1\Delta\sigma_2 }{a_2b_1 - a_1b_2 }$.
- Optimizing for minimal sum of uncertainties $f(\Delta m_{\rm W}, \Delta\Gamma_{\rm W}) = \Delta m_{\rm W} + \Delta\Gamma_{\rm W}$ under fixed total luminosity $\mathcal{L} = 15$ ab$^{-1}$.
- Analyzing the impact of statistical correlations between $\Delta m_{\rm W}$ and $\Delta\Gamma_{\rm W}$ using the correlation coefficient $r(\Delta m, \Delta\Gamma)$.
- Comparing single-point and two-point scan strategies to assess trade-offs in precision for mass versus width measurements.
Experimental results
Research questions
- RQ1What is the optimal energy configuration for measuring both the W boson mass and width with minimal combined uncertainty in a two-point scan near the $WW$ threshold?
- RQ2How does the luminosity fraction allocated to the off-shell energy point affect the precision of $m_{\rm W}$ and $\Gamma_{\rm W}$ measurements?
- RQ3What is the achievable statistical precision on the W boson mass and width using a two-parameter fit compared to a single-parameter fit?
- RQ4How do the projected uncertainties on $m_{\rm W}$ and $\Gamma_{\rm W}$ compare to those from LEP/SLC and other future colliders like ILC or FCC-hh?
- RQ5What is the theoretical and experimental challenge in ensuring that theory uncertainties remain at the same level as experimental uncertainties in high-precision measurements?
Key findings
- The optimal two-point energy scan for minimizing combined uncertainty in $m_{\rm W}$ and $\Gamma_{\rm W}$ is at $E_1 = 157.5$ GeV and $E_2 = 162.3$ GeV with a luminosity fraction $f = 0.45$ at the lower energy point.
- With a total luminosity of 15 ab$^{-1}$, the projected statistical uncertainties are $\Delta m_{\rm W} = 0.41$ MeV and $\Delta \Gamma_{\rm W} = 1.10$ MeV.
- The precision on $m_{\rm W}$ is only slightly better in the two-parameter fit ($\Delta m_{\rm W} = 0.40$ MeV) compared to the single-parameter fit, indicating robustness of the method.
- The single-point scan at $E_0 = 161.4$ GeV yields a superior $\Delta m_{\rm W} = 0.25$ MeV, highlighting a trade-off between mass and width precision.
- For minimal $f = 0.05$ at the off-shell point, the $\Delta m_{\rm W}$ precision reaches 0.28 MeV in both single- and two-parameter fits, showing high sensitivity even with minimal off-shell data.
- The optimal lower energy point $E_1$ is consistently found to be $2m_{\rm W} - (1-2)\Gamma_{\rm W}$, depending on the precision target, ensuring maximal sensitivity to both parameters.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.