Skip to main content
QUICK REVIEW

[Paper Review] Pipeline Processing of VLBI Data

Cormac Reynolds, Z. Paragi|arXiv (Cornell University)|May 8, 2002
Radio Astronomy Observations and TechnologyPhysics and Astronomy8 citations
TL;DR

This paper presents an automated pipeline for VLBI data reduction developed at JIVE to streamline calibration of EVN experiments using AIPS. By processing raw data, applying amplitude and fringe calibration, enabling self-calibration, and generating real-time quality plots, the pipeline reduces user effort and accelerates feedback on data quality, significantly improving array performance and data usability for both monitoring and user experiments.

ABSTRACT

As part of an on-going effort to simplify the data analysis path for VLBI experiments, a pipeline procedure has been developed at JIVE to carry out much of the data reduction required for EVN experiments in an automated fashion. This pipeline procedure runs entirely within AIPS, the standard data reduction package used in astronomical VLBI, and is used to provide preliminary calibration of EVN experiments correlated at the EVN MkIV data processor. As well as simplifying the analysis for EVN users, the pipeline reduces the delay in providing information on the data quality to participating telescopes, hence improving the overall performance of the array. A description of this pipeline is presented here.

Motivation & Objective

  • To simplify the data analysis path for VLBI experiments by automating calibration steps traditionally requiring expert intervention.
  • To reduce the time between correlation and data quality feedback for participating telescopes, improving array performance monitoring.
  • To provide preliminary, partially calibrated datasets to EVN users quickly after correlation.
  • To enable early assessment of data quality via automated plots of calibrator sources, enhancing usability of archived data.
  • To lay the groundwork for future fully automated VLBI data reduction pipelines by minimizing manual user input.

Proposed method

  • The pipeline is implemented as an AIPS procedure to process raw VLBI data in FITS format, automatically loading and cataloging datasets.
  • It applies a priori amplitude calibration using system temperature and gain files provided by stations, correcting for instrumental response.
  • Fringe-fitting is performed to remove frequency-dependent phase slopes, with solutions propagated from bright calibrators to weak targets via phase-referencing.
  • Bandpass calibration is applied to correct for spectral response variations across the bandwidth.
  • Automated flagging is optionally applied based on deviations from mean baseline values, suitable for sources with simple structure.
  • Self-calibration is iteratively applied to bright calibrators to produce a source model and improve dynamic range, with solutions propagated to weak targets.

Experimental results

Research questions

  • RQ1Can an automated pipeline reduce the manual effort required for initial calibration of EVN VLBI experiments?
  • RQ2How quickly can a pipeline provide feedback on data quality after correlation, and what impact does this have on array performance?
  • RQ3To what extent can automated calibration procedures maintain scientific calibration quality for weak target sources?
  • RQ4Can the pipeline-generated plots of calibrator sources enable rapid assessment of archived data quality?
  • RQ5What is the achievable dynamic range of a self-calibrated map using only pipeline-automated steps?

Key findings

  • The pipeline successfully reduces user effort by automating the majority of initial calibration steps, including amplitude calibration, fringe fitting, and bandpass calibration.
  • After just two iterations of self-calibration, the pipeline produces a source map with a dynamic range of approximately 100:1, indicating high-quality calibration.
  • The pipeline enables rapid feedback on data quality, allowing array performance to be monitored in near real time during observing sessions.
  • Automated plots of calibrated visibilities and source models are generated at key stages, facilitating quick assessment of data quality and station performance.
  • The pipeline allows preliminary calibrated datasets to be delivered to users shortly after correlation, improving the usability of archived data.
  • The system demonstrates that automated processing can achieve calibration quality sufficient for scientific analysis, especially when combined with phase-referencing techniques.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.