[Paper Review] Polarization Modeling and Predictions for DKIST Part 4: Calibration Accuracy Over Field of View, Retardance Spatial Uniformity And Achromat Design Sensitivity
This paper models polarization errors in DKIST's calibration optics, focusing on spatial and spectral retardance variations due to polishing errors. It shows that spatial non-uniformity in retardance—reaching ±6° at 543 nm—limits full-field calibration accuracy, with design sensitivity varying by up to a factor of 2 even with identical materials, necessitating advanced calibration techniques for sub-1° accuracy.
Modern observatories and instruments require optics fabricated at larger sizes with more stringent performance requirements. The Daniel K. Inouye Solar Telescope will be the world's largest solar telescope at 4.0 m aperture delivering a 300 Watt beam and a 5 arc-minute field. Spatial variation of retardance is a limitation to calibration of the full field. Three polarimeters operate seven cameras simultaneously in narrow bandpasses from 380 nm to 1800 nm. The DKIST polarization calibration optics must be 120 mm in diameter at Gregorian focus to pass the beam and operate under high heat load, UV flux and environmental variability. Similar constraints apply to the instrument modulators with large beams near focal planes at F/18 to F/62. We assess how design factors can produce more spatial and spectral errors simulating elliptical retardance caused by polishing errors. We measure over 5deg circular retardance and spectral oscillations over +-2 for optics specified as strictly linear retarders. Spatial variations on scales larger than 10 mm contain 90% of the variation. Different designs can be a factor of 2 more sensitive to polishing errors with dissimilar spatial distributions even when using identical retardance bias values and materials. The calibration for the on axis beam is not impacted once circular retardance is included. Calibration of the full field is limited by spatial retardance variation unless techniques account for this variation. We show calibration retarder variation at amplitudes of 1deg retardance for field angles greater than roughly one arc minute for both quartz and MgF_2 retarders at visible wavelengths with significant variation between the three DKIST calibration retarders. We present polishing error maps to inform new calibration techniques attempting to deliver absolute accuracy of system calibration below effective cross-talk levels of 1deg retardance.
Motivation & Objective
- To assess how spatial and spectral variations in retardance affect polarization calibration accuracy across DKIST’s 5 arc-minute field of view.
- To quantify the impact of polishing errors on elliptical retardance and spectral oscillations in linear retarders used in DKIST’s calibration system.
- To evaluate design sensitivity differences between retarder types (e.g., quartz, MgF₂, polycarbonate) in response to fabrication errors.
- To provide detailed polishing error maps for guiding new calibration techniques aiming for sub-1° effective cross-talk levels.
- To determine the role of achromatic design and material choice in minimizing field-dependent polarization errors.
Proposed method
- Simulated spatial and spectral retardance variations using Mueller matrix formalism to model polarization effects across the DKIST field of view.
- Measured spatial retardance non-uniformity across multiple retarders (quartz, MgF₂, polycarbonate) at visible and near-IR wavelengths (380–1800 nm).
- Analyzed error contributions from polishing imperfections, material inhomogeneity, and mounting misalignment using experimental maps from delivered optics.
- Evaluated design sensitivity by comparing retardance variation across different retarder types (zero-order, multi-order, compound, super-achromatic) under identical bias and material conditions.
- Used FLC and polycarbonate retarder data to model voltage-dependent and wavelength-dependent spatial non-uniformity effects.
- Combined tolerance analysis with measured error maps to predict performance limits and calibration requirements.
Experimental results
Research questions
- RQ1How do polishing errors in DKIST calibration retarders induce spatial and spectral variations in elliptical retardance?
- RQ2To what extent does the design of a retarder (e.g., zero-order vs. compound) affect its sensitivity to fabrication errors?
- RQ3What is the magnitude and spatial distribution of retardance non-uniformity in different retarder materials (quartz, MgF₂, polycarbonate) across the field of view?
- RQ4How do spectral oscillations and net circular retardance affect calibration accuracy in the full-field beam?
- RQ5Can polishing error maps be used to develop calibration techniques that achieve sub-1° effective cross-talk in polarization calibration?
Key findings
- Polishing errors in DKIST calibration retarders produce spatially varying elliptical retardance, with magnitudes reaching ±6° at 543 nm and ±4.6° at 870 nm in FLCs.
- Spatial variations larger than 10 mm account for 90% of total retardance variation, indicating that large-scale errors dominate calibration uncertainty.
- Different retarder designs exhibit up to a factor of 2 difference in sensitivity to polishing errors, even when using identical materials and retardance bias values.
- Spectral oscillations in retardance reach ±2° across the visible spectrum, with significant variation between the three DKIST calibration retarders.
- Calibration accuracy for the on-axis beam is not degraded by circular retardance, but full-field calibration is limited by spatial retardance non-uniformity.
- Polycarbonate five-layer super-achromatic retarders show ±2.5° elliptical retardance magnitude errors across a 24 mm aperture at 600 nm, with similar spatial patterns across two samples.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.