[Paper Review] Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter
This paper presents a compact, low-cost, portable rotating waveplate polarimeter that enables complete Stokes vector analysis of collimated light using a quarter-wave plate, polarizer, photodiode, and Arduino-based signal processing. By integrating a photo-interrupter for phase referencing and software-based signal correction, the device achieves sub-degree accuracy on the Poincaré sphere, matching commercial instruments at a fraction of the cost.
Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.
Motivation & Objective
- To develop a low-cost, portable, and self-contained polarimeter for complete Stokes vector characterization of light.
- To enable accurate polarization measurements without reliance on expensive commercial instruments.
- To achieve high accuracy and precision comparable to commercial devices while maintaining compactness and ease of use.
- To provide a calibration method that compensates for phase misalignment using software offset and physical alignment.
Proposed method
- Employs a rotating quarter-wave plate (QWP) at ~π/2 retardance, a fixed polarizer (analyzer), and a photodiode to detect intensity modulated by the QWP's rotation.
- Uses a photo-interrupter and timing disk to generate a trigger signal at a known phase of the QWP rotation, enabling phase referencing.
- Applies Fourier analysis to the detected intensity signal I(θ) = 1/2 [A + B sin(2θ) + C cos(4θ) + D sin(4θ)] to extract Stokes parameters S0, S1, S2, S3.
- Uses an Arduino Pro-Micro microcontroller to perform real-time signal processing, compute the Stokes vector, and display results on an LCD.
- Calibrates the system using a known X-polarized input (S = [1,1,0,0]) and adjusts the software offset in 5.625° increments to align the QWP fast axis with the analyzer.
- Validates performance by rotating upstream polarizer and zero-order QWP while measuring deviations in Poincaré sphere angles (2ψ and 2χ) against expected values.
Experimental results
Research questions
- RQ1Can a low-cost, portable polarimeter achieve Stokes vector accuracy comparable to commercial devices?
- RQ2How does phase referencing via a photo-interrupter improve the accuracy of rotating waveplate polarimetry?
- RQ3To what extent can software-based signal offset compensate for mechanical misalignment in the QWP phase?
- RQ4What is the measurement uncertainty of the Stokes vector components when the upstream polarization state is varied?
- RQ5How stable and repeatable are the polarization measurements across different input states and optical configurations?
Key findings
- The polarimeter achieves a mean deviation of 0.18° and standard deviation of 0.41° for the longitude angle 2ψ when measuring linear polarization, with the polarizer rotated from 0° to 180°.
- For the elevation angle 2χ, the mean deviation is 0.11° and standard deviation is 0.23° when measuring elliptical and circular polarization by rotating the upstream QWP.
- The device's accuracy is within half a standard deviation of zero, demonstrating high consistency and reliability in polarization state measurement.
- The system's performance is quantitatively comparable to commercial instruments such as the Thorlabs PAX1000 series, which has a specified accuracy of ±0.25°.
- The use of a 64-point software offset (5.625° resolution) effectively compensates for mechanical phase misalignment, enabling accurate calibration without requiring perfect physical alignment.
- The device operates over a bandwidth >30 nm and maintains accuracy across a range of wavelengths, demonstrating robustness in practical optical setups.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.