TL;DR

This paper proposes a novel deep learning model, AvgPool_VGG-16, for multiclass classification of hypertension stages using photoplethysmography (PPG) signals. By replacing max pooling with average pooling in a VGG-16 architecture, the model achieves 80% accuracy and 0.77 F1 score on a public PPG dataset, outperforming ResNet-50, VGG-16, AlexNet, and prior models like Xception+BiLSTM.

ABSTRACT

Hypertension is a medical condition characterized by high blood pressure, and classifying it into its various stages is crucial to managing the disease. In this project, a novel method is proposed for classifying stages of hypertension using Photoplethysmography (PPG) signals and deep learning models, namely AvgPool_VGG-16. The PPG signal is a non-invasive method of measuring blood pressure through the use of light sensors that measure the changes in blood volume in the microvasculature of tissues. PPG images from the publicly available blood pressure classification dataset were used to train the model. Multiclass classification for various PPG stages were done. The results show the proposed method achieves high accuracy in classifying hypertension stages, demonstrating the potential of PPG signals and deep learning models in hypertension diagnosis and management.

Motivation & Objective

  • To develop a robust deep learning model for classifying multiple stages of hypertension using non-invasive PPG signals.
  • To address the challenge of low signal-to-noise ratio and inter-individual variability in PPG waveforms for clinical diagnosis.
  • To evaluate the impact of pooling layer types—specifically average pooling versus max pooling—on classification performance in PPG signal analysis.
  • To improve upon existing deep learning models such as AlexNet, ResNet, and VGG-16 in multiclass PPG-based hypertension staging.
  • To provide a scalable, non-invasive, and accurate method for early hypertension detection using consumer-grade PPG sensors.

Proposed method

  • The proposed model, AvgPool_VGG-16, is a modified version of the VGG-16 architecture with average pooling layers replacing max pooling layers in the final convolutional blocks.
  • PPG signals from the public blood pressure classification dataset were pre-processed and converted into 2.1-second waveform images for input to the deep learning models.
  • The model was trained using transfer learning with ImageNet-pretrained weights, fine-tuned on the PPG image dataset for multiclass classification of four hypertension stages: ht1, ht2, nt, pt.
  • Model performance was evaluated using 5-fold cross-validation, with metrics including accuracy, precision, recall, F1 score, and confusion matrices.
  • Comparative analysis was conducted against baseline models: AlexNet, ResNet-50, VGG-16, and Xception+BiLSTM from prior work.
  • The use of average pooling was hypothesized to better preserve signal energy and reduce overfitting in PPG image classification, especially for subtle hemodynamic changes.

Experimental results

Research questions

  • RQ1Does replacing max pooling with average pooling in a VGG-16 architecture improve classification accuracy for PPG-based hypertension staging?
  • RQ2How does the performance of AvgPool_VGG-16 compare to established deep learning models like AlexNet, ResNet-50, and VGG-16 on PPG signal images?
  • RQ3To what extent does dataset class imbalance—particularly for stage-2 hypertension (ht2)—affect model generalization and performance?
  • RQ4Can deep learning models trained on real, pre-processed PPG signals from human subjects achieve clinically relevant accuracy for multiclass hypertension classification?
  • RQ5What is the impact of pooling layer type on feature representation and model robustness in PPG signal image classification tasks?

Key findings

  • The AvgPool_VGG-16 model achieved the highest accuracy of 80% and F1 score of 0.77, outperforming VGG-16 (71% accuracy, 0.69 F1), ResNet-50 (44% accuracy, 0.40 F1), and AlexNet (39% accuracy, 0.22 F1).
  • Average pooling significantly improved model performance compared to max pooling, particularly in preserving subtle hemodynamic features in PPG waveforms.
  • The model demonstrated strong performance on normal (nt) and prehypertension (pt) stages, with 89% and 81% F1 scores respectively, indicating robustness in classifying common hypertension stages.
  • The model struggled most with stage-2 hypertension (ht2), achieving only 10% F1 score due to limited training samples (20 records), highlighting data imbalance as a key limitation.
  • Compared to the Xception+BiLSTM model reported in prior work, AvgPool_VGG-16 achieved 80% accuracy versus 76%, indicating superior performance despite a simpler architecture.
  • Confusion matrix analysis confirmed that the model correctly classified the majority of normal and prehypertensive cases, while misclassifying many ht2 cases as other classes, underscoring the need for data augmentation in future work.