Skip to main content
QUICK REVIEW

[Paper Review] Practical Window Setting Optimization for Medical Image Deep Learning

Hyunkwang Lee, Myeongchan Kim|arXiv (Cornell University)|Dec 3, 2018
Radiomics and Machine Learning in Medical ImagingMedicine9 references23 citations
TL;DR

This paper proposes a trainable Window Setting Optimization (WSO) module for medical image deep learning that uses 1x1 convolutional layers with custom activation functions to automatically learn optimal Hounsfield Unit (HU) windowing ranges for CT images. The method improves performance in intracranial hemorrhage and urinary stone detection by enhancing pathological conspicuity, outperforming models trained on full HU ranges or fixed window settings, with a 97.6% AUC on ICH and 97.2% on stones using sigmoid WSO with dual initialization.

ABSTRACT

The recent advancements in deep learning have allowed for numerous applications in computed tomography (CT), with potential to improve diagnostic accuracy, speed of interpretation, and clinical efficiency. However, the deep learning community has to date neglected window display settings - a key feature of clinical CT interpretation and opportunity for additional optimization. Here we propose a window setting optimization (WSO) module that is fully trainable with convolutional neural networks (CNNs) to find optimal window settings for clinical performance. Our approach was inspired by the method commonly used by practicing radiologists to interpret CT images by adjusting window settings to increase the visualization of certain pathologies. Our approach provides optimal window ranges to enhance the conspicuity of abnormalities, and was used to enable performance enhancement for intracranial hemorrhage and urinary stone detection. On each task, the WSO model outperformed models trained over the full range of Hounsfield unit values in CT images, as well as images windowed with pre-defined settings. The WSO module can be readily applied to any analysis of CT images, and can be further generalized to tasks on other medical imaging modalities.

Motivation & Objective

  • To address the underutilization of windowing settings in deep learning for medical imaging, despite their critical role in clinical radiology.
  • To develop a differentiable, end-to-end trainable module that learns optimal window settings (window level and width) for improved diagnostic performance.
  • To demonstrate that task-specific window optimization enhances model performance beyond fixed or full-range HU input.
  • To generalize the approach to other CT tasks and medical imaging modalities like MRI and PET.

Proposed method

  • The WSO module uses 1x1 convolutional layers with learnable weights and biases to emulate linear or sigmoid windowing functions.
  • The windowing function is defined as $ F_{lin}(x) = \min(\max(Wx + b, 0), U) $ with $ W = \frac{U}{WW} $, $ b = -\frac{U}{WW}(WL - \frac{WW}{2}) $, enabling differentiable optimization.
  • For sigmoid windowing, $ F_{sig}(x) = \frac{U}{1 + e^{-(Wx + b)}} $, with $ W $ and $ b $ derived from target window level and width.
  • The WSO layer is inserted before the main CNN (Inception-v3), allowing backpropagation to tune window parameters during training.
  • Initialization of WSO parameters is based on standard clinical window settings (e.g., 'brain', 'subdural', 'bone', 'abdomen') to guide optimization.
  • The model is trained using Adam optimizer with learning rate decay, and best models are selected based on validation loss.

Experimental results

Research questions

  • RQ1Can a differentiable, learnable windowing module improve deep learning performance in CT image analysis compared to fixed or full-range HU inputs?
  • RQ2Does optimizing window settings in a task-specific manner enhance the conspicuity of pathologies like intracranial hemorrhage and urinary stones?
  • RQ3How does the choice of windowing function (linear vs. sigmoid) affect model performance in medical image classification?
  • RQ4Can the WSO module be generalized to other medical imaging modalities beyond CT?

Key findings

  • The WSO model with sigmoid windowing and dual initialization achieved a 97.6% AUC on intracranial hemorrhage detection, surpassing the best baseline of 96.9%.
  • For urinary stone detection, the WSO model reached 97.2% AUC, outperforming the next best baseline of 94.6%.
  • Models trained on pre-windowed images with standard settings (e.g., 'brain', 'subdural') outperformed models using full HU range images, indicating the value of windowing.
  • The WSO module with sigmoid activation and initialization from two standard settings yielded the highest performance, suggesting benefit from multi-prior initialization.
  • The WSO-optimized window settings made pathologies like hemorrhage and stones more conspicuous in the feature space, as visualized in Figure 3.
  • The method is generalizable and can be applied to other CT tasks such as object detection and segmentation, as well as to other modalities like MRI and PET.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint