[Paper Review] Preliminary results on the long term operation of RPCs with eco-friendly gas mixtures under irradiation at the CERN Gamma Irradiation Facility
This study evaluates eco-friendly gas mixtures—specifically HFO-1234ze and CO2—replacing traditional high-GWP gases in resistive-plate chambers (RPCs) under long-term irradiation at CERN's Gamma Irradiation Facility. Preliminary results show stable current response over 12 months of irradiation, with efficiency reductions of 4–8% under high background, and a reduced operational voltage window for eco-friendly mixtures due to increased large-signal contamination.
Since 2019 a collaboration between researchers from various institutes and experiments (i.e. ATLAS, CMS, ALICE, LHCb/SHiP and the CERN EP-DT group), has been operating several RPCs with diverse electronics, gas gap thicknesses and detector layouts at the CERN Gamma Irradiation Facility (GIF++). The studies aim at assessing the performance of RPCs when filled with new eco-friendly gas mixtures in avalanche mode and in view of evaluating possible ageing effects after long high background irradiation periods, e.g. High-Luminosity LHC phase. This challenging research is also part of a task of the European AidaInnova project. A promising eco-friendly gas identified for RPC operation is the tetrafluoruropropene (C$_{3}$H$_{2}$F$_{4}$, commercially known as HFO-1234ze) that has been studied at the CERN GIF++ in combination with different percentages of CO$_2$. Between the end of 2021 and 2022 several beam tests have been carried out to establish the performance of RPCs operated with such mixtures before starting the irradiation campaign for the ageing study. Results of these tests for different RPCs layouts and different gas mixtures, under increasing background rates are presented here, together with the preliminary outcome of the detector ageing tests.
Motivation & Objective
- To assess the long-term performance and aging effects of RPCs using eco-friendly gas mixtures with low global warming potential (GWP).
- To replace high-GWP gases like C2H2F4 (GWP 1430) and SF6 (GWP 22800) in RPCs used at the LHC.
- To evaluate the feasibility of HFO-1234ze and CO2 mixtures as sustainable alternatives in RPC operation under high-background irradiation.
- To support CERN’s and the EU’s phase-down goals for fluorinated greenhouse gases (F-GHGs) in particle physics detectors.
- To provide data for future deployment in High-Luminosity LHC (HL-LHC) upgrades.
Proposed method
- Operation of multiple RPCs with varying gas gap thicknesses, electronics, and geometries at the CERN Gamma Irradiation Facility (GIF++).
- Use of HFO-1234ze (C3H2F4) mixed with CO2 at different concentrations (e.g., 35/50 HFO/CO2) as eco-friendly alternatives to C2H2F4/SF6 mixtures.
- Long-term irradiation campaign using a 137Cs source to simulate high-background conditions expected in HL-LHC.
- Monitoring of absorbed current, dark current, and Ohmic component over ~1 year to assess stability and aging effects.
- Beam tests at increasing background rates before irradiation to establish baseline performance (efficiency, charge spectrum, plateau voltage).
- Periodic beam tests (e.g., July 2023) to compare pre- and post-irradiation performance and validate aging trends.

Experimental results
Research questions
- RQ1How do eco-friendly HFO-1234ze/CO2 gas mixtures affect RPC efficiency and signal charge under long-term high-background irradiation?
- RQ2What is the impact of increasing HFO concentration on the operational voltage window and large-signal contamination in RPCs?
- RQ3How does irradiation affect the stability of dark and absorbed current in RPCs with eco-friendly gas mixtures over time?
- RQ4To what extent does the presence of HFO reduce the detector’s efficiency under high-background conditions compared to standard gas mixtures?
- RQ5Can the performance degradation of RPCs with eco-friendly mixtures be quantified and correlated with irradiation dose and gas composition?
Key findings
- The plateau efficiency of RPCs with HFO-1234ze/CO2 mixtures decreased by 4–8% under the highest irradiation conditions, compared to 1–2% for standard gas mixtures.
- The operating voltage (WP) increased by approximately 1 kV for every 10% increase in HFO concentration, indicating a need for higher voltage to achieve full efficiency.
- The fraction of events with large signal charge increased more sharply with voltage in HFO-based mixtures, reducing the useful operating voltage range where efficiency exceeds 95% and large-signal contamination is below 5%.
- The absorbed current under irradiation remained stable over ~12 months of exposure, indicating good long-term current stability for the ECO2 (35/50 HFO/CO2) mixture.
- The Ohmic component of the dark current showed minimal variation over time, while the total dark current exhibited more fluctuations, suggesting possible surface or material effects under irradiation.
- Beam tests in July 2023 are ongoing to compare pre- and post-irradiation performance, with results expected to confirm aging trends and validate long-term behavior.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.