[Paper Review] Probing axonal swelling with time dependent diffusion MRI

Hong‐Hsi Lee, Antonios Papaioannou|arXiv (Cornell University)|Jul 29, 2019
Advanced Neuroimaging Techniques and ApplicationsMedicine48 references2 citations
TL;DR

This study introduces a time-dependent diffusion MRI method that detects micrometer-scale axonal caliber variations and pathological beading by identifying a power-law dependence of the along-fiber diffusion coefficient on diffusion time. The method reveals decreased time-dependence in multiple sclerosis lesions, demonstrating sensitivity to microstructural pathology with clinical feasibility.

ABSTRACT

MRI provides a unique non-invasive window into the brain, yet is limited to millimeter resolution, orders of magnitude coarser than cell dimensions. Here we show that diffusion MRI is sensitive to the micrometer-scale variations in axon caliber or pathological beading, by identifying a signature power-law diffusion time-dependence of the along-fiber diffusion coefficient. We observe this signature in human brain white matter, and uncover its origins by Monte Carlo simulations in realistic substrates from 3d electron microscopy of mouse corpus callosum. Simulations reveal that the time-dependence originates from axon caliber variation, rather than from mitochondria or axonal undulations. We report a decreased amplitude of time-dependence in multiple sclerosis lesions, illustrating the sensitivity of our method to axonal beading in a plethora of neurodegenerative disorders. This specificity to microstructure offers an exciting possibility of bridging across scales to image cellular-level pathology with a clinically feasible MRI technique.

Motivation & Objective

  • To develop a clinically feasible MRI technique sensitive to micrometer-scale axonal microstructure.
  • To distinguish axonal caliber variations from other subcellular features like mitochondria or undulations.
  • To detect pathological axonal beading in neurodegenerative disorders such as multiple sclerosis.
  • To bridge the resolution gap between MRI and cellular-scale neuroanatomy.
  • To validate the method using both human data and Monte Carlo simulations on electron microscopy data.

Proposed method

  • The method analyzes the time-dependence of the along-fiber diffusion coefficient in diffusion MRI sequences.
  • It identifies a power-law scaling of the diffusion coefficient with diffusion time as a signature of axonal caliber variation.
  • Monte Carlo simulations are performed on 3D electron microscopy reconstructions of mouse corpus callosum to model diffusion in realistic axonal geometries.
  • The simulations isolate the contribution of caliber variation from other microstructural features such as mitochondria and axonal undulations.
  • The method is validated in human brain white matter data to detect time-dependent diffusion signatures.
  • The approach enables quantification of microstructural changes in pathological conditions like multiple sclerosis.

Experimental results

Research questions

  • RQ1Can time-dependent diffusion MRI detect micrometer-scale axonal caliber variations that are below conventional MRI resolution?
  • RQ2What is the origin of the observed time-dependence in diffusion coefficients—axonal caliber variation, mitochondria, or axonal undulations?
  • RQ3Does the amplitude of time-dependence change in neurodegenerative pathologies such as multiple sclerosis?
  • RQ4Can this method provide a clinically feasible way to image cellular-level pathology in vivo?
  • RQ5How does the power-law scaling of diffusion coefficient with time relate to actual axonal microstructure?

Key findings

  • The along-fiber diffusion coefficient exhibits a power-law dependence on diffusion time, serving as a signature of axonal caliber variation.
  • This time-dependence is absent in simulations where axonal caliber is uniform, confirming its origin in caliber fluctuations.
  • Monte Carlo simulations confirm that the time-dependence arises from axonal caliber variation, not from mitochondria or axonal undulations.
  • In human white matter, the power-law signature is consistently observed, validating its physiological relevance.
  • In multiple sclerosis lesions, the amplitude of time-dependence is significantly reduced, indicating axonal beading or caliber disruption.
  • The method demonstrates sensitivity to microstructural pathology at a scale previously inaccessible to conventional MRI.