[Paper Review] Probing squeezing for gravitational-wave detectors with an audio-band field

D. Ganapathy, Victoria Xu|arXiv (Cornell University)|Mar 8, 2022
Pulsars and Gravitational Waves ResearchPhysics and Astronomy32 references7 citations
TL;DR

This paper introduces an audio diagnostic field (ADF) to enable real-time, in-situ probing of frequency-dependent squeezing in gravitational-wave detectors. By co-propagating a low-frequency audio-sideband with squeezed light, the ADF allows homodyne detection to rapidly characterize squeezing degradation and system response—demonstrated experimentally on a 16 m filter cavity and simulated for a 300 m Advanced LIGO filter cavity, enabling faster optimization of quantum noise reduction in next-generation detectors.

ABSTRACT

Squeezed vacuum states are now employed in gravitational-wave interferometric detectors, enhancing their sensitivity and thus enabling richer astrophysical observations. In future observing runs, the detectors will incorporate a filter cavity to suppress quantum radiation pressure noise using frequency-dependent squeezing. Interferometers employing internal and external cavities decohere and degrade squeezing in complex new ways, which must be studied to achieve increasingly ambitious noise goals. This paper introduces an audio diagnostic field (ADF) to quickly and accurately characterize the frequency-dependent response and the transient perturbations of resonant optical systems to squeezed states. This analysis enables audio field injections to become a powerful tool to witness and optimize interactions such as inter-cavity mode matching within gravitational-wave instruments. To demonstrate, we present experimental results from using the audio field to characterize a 16 m prototype filter cavity.

Motivation & Objective

  • To develop a real-time diagnostic tool for probing squeezing degradation in complex optical systems of gravitational-wave detectors.
  • To overcome limitations of traditional methods that require mode-switching and long averaging times.
  • To enable continuous monitoring of squeezing performance during normal detector operation.
  • To support the integration of frequency-dependent squeezing using filter cavities in next-generation detectors like Advanced LIGO.
  • To provide a scalable method for optimizing inter-cavity mode matching and transient response in resonant optical systems.

Proposed method

  • Injects an audio diagnostic field (ADF) at a small audio-frequency offset from the main carrier, co-propagating with squeezed light.
  • Uses homodyne detection of the ADF to extract real and imaginary quadratures at the audio frequency.
  • Employs a coherent locking field (CLF) for phase stabilization, with the ADF operating within the OPO linewidth to mimic squeezed field behavior.
  • Models the ADF response using coupled-mode theory and transfer functions to relate detected signals to optical system parameters.
  • Derives analytical expressions for ADF amplitude and phase in terms of cavity round-trip gain and phase, enabling quantitative characterization.
  • Validates the method experimentally on a 16 m prototype filter cavity and simulates performance for a 300 m Advanced LIGO filter cavity.

Experimental results

Research questions

  • RQ1How can squeezing degradation in resonant optical systems be probed in real time without disrupting normal detector operation?
  • RQ2What is the relationship between the detected ADF signal and the underlying optical system response, including phase noise and mode-matching errors?
  • RQ3How accurately can the ADF method characterize the frequency-dependent response of a quantum filter cavity?
  • RQ4Can the ADF method detect and quantify transient perturbations affecting squeezing propagation?
  • RQ5What is the expected performance of the ADF method in large-scale gravitational-wave detectors with complex, frequency-dependent squeezing?

Key findings

  • The ADF method enables real-time, in-situ characterization of squeezing response in resonant optical systems, avoiding the need for mode-switching or long averaging times.
  • Experimental results on a 16 m filter cavity show good agreement between measured ADF response and theoretical predictions, validating the method’s accuracy.
  • The ADF signal amplitude and phase are directly related to the cavity’s round-trip gain and phase, allowing quantitative inference of system parameters.
  • Simulations for a 300 m Advanced LIGO filter cavity indicate the ADF can resolve frequency-dependent squeezing response with high fidelity.
  • The method successfully detects and characterizes transient perturbations in the optical system that affect squeezing, enabling faster optimization.
  • The ADF provides a scalable diagnostic tool for optimizing inter-cavity mode matching and squeezing performance in future gravitational-wave detectors.