Skip to main content
QUICK REVIEW

[Paper Review] Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2

Z. Galloway, V. Fadeyev|arXiv (Cornell University)|Jul 16, 2017
Particle Detector Development and PerformancePhysics and Astronomy16 references19 citations
TL;DR

This study investigates the performance of Hamamatsu Photonics' Ultra-Fast Silicon Detectors (HPK UFSD) after neutron irradiation up to 6×10¹⁵ n/cm². The detectors, based on Low-Gain Avalanche Diodes (LGADs), exhibit a significant drop in internal gain from ~80 to 7 and a timing resolution degradation from 20 ps to 50 ps due to radiation-induced acceptor removal, with optimal time resolution achieved at a 60% constant fraction discriminator threshold at the highest fluence.

ABSTRACT

In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.

Motivation & Objective

  • To evaluate the radiation hardness of HPK UFSDs under neutron fluences up to 6×10¹⁵ n/cm².
  • To understand the impact of neutron irradiation on key detector parameters: leakage current, internal gain, and timing resolution.
  • To determine the optimal constant fraction discriminator (CFD) threshold for time-of-flight measurements post-irradiation.
  • To correlate observed pulse shape changes with radiation-induced defects using the WF2 simulation program.

Proposed method

  • Neutron irradiation was performed at fluences of 1×10¹⁴, 3×10¹⁴, 6×10¹⁴, 1×10¹⁵, 3×10¹⁵, and 6×10¹⁵ n/cm².
  • Pre- and post-irradiation measurements were conducted using a ⁹⁰Sr β-source to expose the UFSDs to minimum ionizing particles (MIPs).
  • Leakage current, internal gain, and timing resolution were measured as functions of bias voltage at -20°C and -30°C.
  • Timing resolution was extracted using the constant fraction method in coincidence with a calibrated reference UFSD.
  • Pulse shape changes were analyzed and compared with simulations using the WF2 program to model radiation-induced defects.
  • The dependence of timing resolution on CFD threshold was systematically studied across all fluence levels.

Experimental results

Research questions

  • RQ1How does neutron irradiation affect the internal gain of HPK UFSDs across fluences up to 6×10¹⁵ n/cm²?
  • RQ2What is the evolution of timing resolution with increasing neutron fluence, and how does it depend on the CFD threshold setting?
  • RQ3How do radiation-induced defects alter the pulse shape characteristics, such as rise time, pulse height, and sensitivity to initial charge deposition?
  • RQ4To what extent do the observed pulse shape changes align with predictions from the WF2 simulation program?
  • RQ5What is the optimal CFD threshold setting for achieving the best time resolution at each irradiation fluence level?

Key findings

  • The internal gain of HPK UFSDs decreased from approximately 80 before irradiation to 7 after exposure to 6×10¹⁵ n/cm².
  • Timing resolution deteriorated from 20 ps pre-irradiation to 50 ps at the highest fluence of 6×10¹⁵ n/cm².
  • The optimal CFD threshold for time resolution shifted from 10% at low fluence to 60% at 6×10¹⁵ n/cm².
  • Pulse rise time shortened, pulse height decreased, and sensitivity to initial charge non-uniformity reduced due to irradiation.
  • The observed pulse shape changes were in good agreement with simulations from the WF2 program.
  • The gain degradation is consistent with the acceptor removal model, indicating radiation-induced defect formation in the LGAD structure.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.