TL;DR

Q-BiC is a biocompatible, integrated microfluidic chip enabling in vitro and in vivo spin-based quantum sensing using nitrogen-vacancy centers in nanodiamonds. It combines on-chip microwave delivery and temperature control to allow non-invasive, nanoscale thermometry in living cells and Caenorhabditis elegans, demonstrating safe microwave exposure limits and minimal stress in immobilized, non-anaesthetized nematodes.

ABSTRACT

Optically addressable spin-based quantum sensors enable nanoscale measurements of temperature, magnetic field, pH, and other physical properties of a system. Advancing the sensors beyond proof-of-principle demonstrations in living cells and multicellular organisms towards reliable, damage-free quantum sensing poses three distinct technical challenges. First, spin-based quantum sensing requires optical accessibility and microwave delivery. Second, any microelectronics must be biocompatible and designed for imaging living specimens. Third, efficient microwave delivery and temperature control are essential to reduce unwanted heating and to maintain an optimal biological environment. Here, we present the Quantum Biosensing Chip (Q-BiC), which facilitates microfluidic-compatible microwave delivery and includes on-chip temperature control. We demonstrate the use of Q-BiC in conjunction with nanodiamonds containing nitrogen vacancy centers to perform optically detected magnetic resonance in living systems. We quantify the biocompatibility of microwave excitation required for optically detected magnetic resonance both in vitro in HeLa cells and in vivo in the nematode Caenorhabditis elegans for temperature measurements and determine the microwave-exposure range allowed before detrimental effects are observed. In addition, we show that nanoscale quantum thermometry can be performed in immobilised but non-anaesthetised adult nematodes with minimal stress. These results enable the use of spin-based quantum sensors without damaging the biological system under study, facilitating the investigation of the local thermodynamic and viscoelastic properties of intracellular processes.

Motivation & Objective

  • To address the challenge of delivering microwave fields and maintaining biocompatible conditions during spin-based quantum sensing in living specimens.
  • To develop a microfluidic-compatible, biocompatible platform that integrates microwave delivery and real-time temperature control for in vitro and in vivo applications.
  • To quantify the biocompatibility threshold of microwave exposure for optically detected magnetic resonance in living cells and multicellular organisms.
  • To enable non-invasive, nanoscale quantum thermometry in live, immobilized but non-anaesthetized C. elegans with minimal physiological stress.
  • To facilitate the study of intracellular thermodynamic and viscoelastic properties using quantum sensors without damaging biological systems.

Proposed method

  • Design and fabrication of a microfluidic-compatible, biocompatible chip (Q-BiC) with integrated microwave transmission lines and on-chip temperature sensors.
  • Use of Parylene C coating to protect electronic components from electrolytic media and enhance biocompatibility.
  • Integration of nanodiamonds with nitrogen-vacancy (NV) centers as exogenous quantum sensors for optically detected magnetic resonance (ODMR).
  • Employment of a 10x air objective and 488 nm laser excitation for fluorescence detection, with Z-stacks acquired at 2.5 µm intervals for 3D imaging.
  • Application of a custom image analysis pipeline using discrete cosine transform, background subtraction, skeletonization, and geodesic distance computation to estimate worm volume and normalize GFP signal.
  • Use of the lys-3::GFP stress reporter in C. elegans to quantify stress response under microwave and thermal exposure, normalized to control conditions.

Experimental results

Research questions

  • RQ1What is the maximum microwave power level that can be applied without causing detectable biological damage in living cells and C. elegans?
  • RQ2How can microwave delivery and temperature control be co-integrated on a single chip to enable stable, non-invasive quantum sensing in living systems?
  • RQ3Can nanoscale quantum thermometry be reliably performed in immobilized but non-anaesthetized C. elegans without inducing stress or altering physiological states?
  • RQ4To what extent does microwave exposure alter the local temperature profile and affect biological specimen viability during quantum sensing?
  • RQ5How can image-based normalization of GFP fluorescence be achieved to accurately quantify stress responses in live, moving, or immobilized specimens?

Key findings

  • Q-BiC enables stable, biocompatible microwave delivery and on-chip temperature monitoring, reducing dielectric heating and maintaining optimal biological conditions.
  • Microwave exposure up to 22.3 dBm (approximately 170 mW) was found to be non-detrimental to HeLa cells and C. elegans, with no significant increase in lys-3::GFP stress reporter expression.
  • Nanoscale quantum thermometry was successfully demonstrated in immobilized, non-anaesthetized adult C. elegans, with minimal physiological stress observed.
  • The use of Parylene C-coated Q-BiC enabled long-term compatibility with liquid culture media and reduced electronic degradation.
  • Image analysis using skeletonization and geodesic distance computation enabled accurate worm volume estimation, improving normalization of GFP signal across specimens.
  • Normalization of GFP signal relative to control groups revealed that microwave exposure did not induce non-specific stress responses, confirming biocompatibility within tested power limits.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.