[Paper Review] Quantum amplitude estimation algorithms on IBM quantum devices
This paper compares two near-term quantum amplitude estimation algorithms—Maximum Likelihood QAE (MLQAE) and Iterative QAE (IQAE)—on IBM quantum devices and simulators. It demonstrates that IQAE outperforms MLQAE in noisy NISQ environments due to lower circuit depth, while both achieve comparable accuracy in noise-free simulations, highlighting the critical impact of quantum noise on algorithmic performance in current hardware.
Since the publication of the Quantum Amplitude Estimation (QAE) algorithm by Brassard et al., 2002, several variations have been proposed, such as Aaronson et al., 2019, Grinko et al., 2019, and Suzuki et al., 2020. The main difference between the original and the variants is the exclusion of Quantum Phase Estimation (QPE) by the latter. This difference is notable given that QPE is the key component of original QAE, but is composed of many operations considered expensive for the current NISQ era devices. We compare two recently proposed variants (Grinko et al., 2019 and Suzuki et al., 2020) by implementing them on the IBM Quantum device using Qiskit, an open source framework for quantum computing. We analyze and discuss advantages of each algorithm from the point of view of their implementation and performance on a quantum computer.
Motivation & Objective
- To evaluate the practical performance of two recent quantum amplitude estimation (QAE) algorithms—MLQAE and IQAE—on real NISQ-era quantum hardware.
- To isolate the effect of quantum noise on algorithm accuracy by comparing runs on IBM Quantum devices and simulators.
- To assess the trade-offs between circuit depth, number of oracle calls, and estimation accuracy in near-term quantum computing.
- To provide empirical insights into the feasibility and limitations of QAE variants for quantum Monte Carlo integration on current noisy hardware.
Proposed method
- Implementing MLQAE and IQAE on IBM Quantum devices (Vigo) and the IBM Q Simulator using Qiskit for 2-, 3-, and 10-qubit domains.
- Using MLQAE with m=3, which involves circuits with up to Q⁴ operations, relying on maximum likelihood estimation from measurement outcomes.
- Applying IQAE with error tolerance of 0.01 and 0.005, iteratively optimizing the amplitude estimation through repeated circuit runs and feedback.
- Comparing relative error and estimation accuracy across different numbers of shots and oracle calls, distinguishing device noise from ideal simulation results.
- Analyzing circuit depth and number of controlled operations to explain performance differences between the two algorithms on noisy hardware.
- Using Monte Carlo integration of sin²x on [0, π/4] as a benchmark to evaluate algorithmic performance.
Experimental results
Research questions
- RQ1How do MLQAE and IQAE perform in terms of accuracy and efficiency when implemented on real IBM quantum devices with noise?
- RQ2What is the impact of quantum device noise on amplitude estimation accuracy, and how does it differ between MLQAE and IQAE?
- RQ3Why does MLQAE show significantly higher error on devices compared to simulators, despite similar performance in noise-free conditions?
- RQ4How does circuit depth affect the reliability of QAE algorithms on NISQ devices, particularly in the context of Q⁴ operations in MLQAE?
- RQ5To what extent do the number of oracle calls and shots influence the relative error in both MLQAE and IQAE on real hardware and simulators?
Key findings
- IQAE outperforms MLQAE on IBM Quantum device Vigo due to lower circuit depth, as MLQAE’s Q⁴ circuit introduces excessive noise.
- For the 2-qubit domain, device runs of MLQAE show relative error up to 10 times higher than simulator runs, with estimated amplitude values deviating by a factor of 2 from the true value.
- The 10-qubit case on the simulator shows near-perfect agreement with the true amplitude for both algorithms, with relative error reduced by nearly an order of magnitude compared to 2- and 3-qubit cases.
- In the absence of noise, MLQAE (m=3) and IQAE (tolerance 0.01) show comparable accuracy and require a similar number of oracle calls to achieve the same error level.
- For the 3-qubit case, IQAE exhibits higher relative error than 2-qubit IQAE due to increased circuit depth and accumulated noise, confirming the sensitivity of iterative algorithms to circuit length.
- Device runs of IQAE with higher error tolerance (0.005) required Q⁴ and even Q⁷ operations, leading to unacceptably noisy results, indicating a practical limit on iterative refinement in noisy hardware.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.