This paper presents the R&D status of fine-pixel charge-coupled devices (FPCCD) for the International Linear Collider (ILC) vertex detector, focusing on 6 µm pixel sensors and a two-phase CO2 cooling system. The FPCCD sensors use fine-pixel geometry and multi-port readout to reduce background occupancy and enable cluster-based background rejection, while two-phase CO2 cooling offers efficient, isothermal heat removal with minimal vibration risk at −40 °C.
Fine pixel CCD (FPCCD) is an option for the sensor used for the ILC vertex detector to reduce the pixel occupancy due to the high background rate near the interaction point. In this paper, we report on the R&D status of FPCCD sensors and the R&D plan for the sensors and the cooling system.
Motivation & Objective
- Develop ultra-fine pixel CCD sensors (down to 6 µm) for the ILC vertex detector to minimize pixel occupancy under high beam background.
- Enable effective background rejection through high spatial resolution and cluster shape analysis using fine-pixel geometry.
- Design a low-vibration, efficient cooling system for FPCCD sensors operating at −40 °C to mitigate radiation damage.
- Implement multi-port readout with embedded horizontal shift registers to support 200 ms beam-train readout.
- Advance cooling technology using two-phase CO2 for high heat flux at ladder ends, ensuring isothermal operation.
Proposed method
- Fabricate fully depleted CCDs with epitaxial layers as thin as 15 µm and pixel sizes down to 6 µm using wafer bonding and epitaxial growth.
- Use four output nodes and embedded horizontal shift registers within the image area to enable high-speed, multi-port readout.
- Employ two-phase CO2 cooling by exploiting latent heat of evaporation at −40 °C to achieve isothermal cooling with low flow rate (0.5 g/s).
- Utilize CO2’s high latent heat (321 J/g at −40 °C) and favorable phase behavior to reduce tube diameter and minimize vibration risks.
- Integrate cooling at ladder ends where heat is concentrated, using high-pressure CO2 (1 MPa at −40 °C) to maintain stable two-phase flow.
- Collaborate with ILD TPC, Belle-II, and KEK groups to validate and scale the two-phase CO2 cooling system for detector applications.
Experimental results
Research questions
- RQ1Can 6 µm pixel CCD sensors achieve sufficient spatial resolution and cluster shape fidelity for effective background rejection in high-background ILC environments?
- RQ2How can multi-port readout with embedded horizontal shift registers enable efficient 200 ms beam-train readout without compromising radiation immunity?
- RQ3Is two-phase CO2 cooling viable for the FPCCD vertex detector at −40 °C, given its proximity to CO2’s triple point?
- RQ4Can two-phase CO2 cooling provide isothermal operation with minimal vibration and low flow rate, especially at the ladder ends with high heat load?
- RQ5What are the thermal and mechanical trade-offs of using CO2 versus perfluorocarbons in a high-precision, low-mass vertex detector system?
Key findings
- A prototype FPCCD sensor with 6 µm square pixels and a 6.1 mm × 6.1 mm sensitive area was successfully fabricated and delivered in March 2010.
- The sensor features four output nodes and embedded horizontal shift registers that are also sensitive, eliminating sensitivity gaps between quadrants.
- Two-phase CO2 cooling requires only 0.5 g/s flow rate at 50% evaporation to remove 80 W of heat, significantly less than alternative coolants.
- CO2 has a higher latent heat (321 J/g at −40 °C) than perfluorocarbons (e.g., ∼100–110 J/g), enabling more efficient heat transfer with smaller flow and tube size.
- The cooling system is expected to provide near-isothermal operation along the cooling tube, reducing thermal gradients and mechanical stress.
- R&D collaboration has been initiated with ILD TPC, Belle-II vertex, and KEK cryogenic groups to validate and scale the two-phase CO2 cooling system.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.