Skip to main content
QUICK REVIEW

[Paper Review] Radio-assay of Titanium samples for the LUX Experiment

D. S. Akerib, X. Bai|arXiv (Cornell University)|Dec 6, 2011
Dark Matter and Cosmic PhenomenaPhysics and Astronomy3 references15 citations
TL;DR

This paper presents a low-background radio-assay of titanium samples for use in the LUX dark matter experiment's cryostats, demonstrating that CP-1 grade titanium (ASTM B-265 Grade 1) exhibits exceptionally low levels of long-lived radioisotopes—<0.25 mBq/kg 238U, <0.2 mBq/kg 232Th, and <1.2 mBq/kg 40K—making it ideal for rare-event searches. Cosmogenic 46 Sc activation was observed in some samples due to muon-induced spallation, but levels decayed significantly over time, confirming titanium is viable for low-background applications when stored at low altitudes.

ABSTRACT

We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample with the lowest total long-lived activity was measured to contain &lt;0.25 mBq/kg of U-238, &lt;0.2 mBq/kg of Th-232, and &lt;1.2 mBq/kg of K-40. Measurements of several samples also indicated the presence of short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon initiated (n,p) reactions.

Motivation & Objective

  • To identify and select low-radioactivity titanium materials for use in the cryostats of the Large Underground Xenon (LUX) dark matter experiment.
  • To evaluate the radio-purity of different titanium grades (CP-1 and CP-2) to minimize background from long-lived isotopes such as 238U, 232Th, and 40K.
  • To assess the impact of cosmogenic activation, particularly 46 Sc, produced via muon-induced (n,p) reactions in titanium during transport and storage.
  • To establish that titanium, particularly CP-1 grade, is a viable alternative to stainless steel or copper in low-background experiments.
  • To provide quantitative radio-assay data for titanium samples from multiple low-background facilities to support material selection for LUX.

Proposed method

  • Radio-assay of titanium samples using high-purity germanium (HPGe) gamma-ray spectrometry at low-background facilities: the Low Background Facility at Lawrence Berkeley National Laboratory, the Oroville Counting Facility, and the SOLO facility at the Soudan Underground Laboratory.
  • Measurement of gamma-ray emissions from 238U, 232Th, 40K, and 46Sc isotopes to determine their specific activities in mBq/kg.
  • Use of 90% confidence level (CL) upper limits for non-detections and ±1σ uncertainties for positive detections.
  • Long-term monitoring of samples (e.g., Ti6 and Ti3) over 2–3 years to track decay of short-lived 46Sc (84-day half-life) and assess cosmogenic activation levels.
  • Comparison of radioactivity levels across different titanium grades (CP-1 and CP-2) and forms (plate, sheet, wire) to identify the lowest-activity material.
  • Evaluation of 46Sc production via (n,p) reactions on 46Ti using neutron energy cross-section data (σ ~ 0.25 barns for 5–20 MeV neutrons) to model cosmogenic activation from muon spallation.

Experimental results

Research questions

  • RQ1What is the level of long-lived radioactivity (238U, 232Th, 40K) in different grades and forms of titanium used for cryostat construction?
  • RQ2To what extent does cosmogenic activation via muon-induced spallation produce 46Sc in titanium during transport and storage?
  • RQ3How does the 46Sc activity evolve over time, and can it be mitigated through storage conditions?
  • RQ4Is CP-1 grade titanium (ASTM B-265 Grade 1) sufficiently radio-pure to be used in low-background experiments like LUX?
  • RQ5How do the radio-assay results for titanium compare to those of traditional materials like stainless steel and copper in terms of background suppression?

Key findings

  • The CP-1 grade titanium (ASTM B-265 Grade 1) sample exhibited the lowest long-lived radioactivity, with <0.25 mBq/kg of 238U, <0.2 mBq/kg of 232Th, and <1.2 mBq/kg of 40K, well below the 1 mBq/kg tolerance limit for LUX.
  • CP-2 grade titanium showed significantly higher levels of 232Th and 238U compared to CP-1, indicating grade-dependent radio-purity.
  • Cosmogenic 46Sc was detected in several samples, with activities ranging from <0.19 mBq/kg to as high as 23 mBq/kg, primarily due to muon-induced spallation during transport.
  • After a 3-year storage period at sea level, the 46Sc activity in Ti6-A had decayed to undetectable levels, confirming that cosmogenic activation is transient and manageable.
  • A sample stored at the high-altitude Sanford Underground Research Facility (SURF) for 6 months showed a 46Sc activity of 4.4 ± 0.3 mBq/kg, indicating measurable cosmogenic activation at high altitudes.
  • The study confirms that titanium, especially CP-1 grade, is a highly suitable material for low-background experiments due to its low intrinsic radioactivity and mechanical advantages over copper and stainless steel.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.