TL;DR

This paper presents a comprehensive radiopurity assessment of materials and radon levels for the NEXT double beta decay experiment at the Canfranc Underground Laboratory. Using ultra-low background HPGe spectrometry, GDMS, and ICPMS, it identifies ultra-pure materials for shielding, vessel, and detector components, while in-situ radon measurements optimize mitigation strategies, achieving a 10-fold reduction in radon activity with high-flow nitrogen flushing—critical for reaching the target background level of 8×10⁻⁴ counts keV⁻¹kg⁻¹y⁻¹.

ABSTRACT

The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

Motivation & Objective

  • To achieve ultra-low background conditions for the NEXT neutrinoless double beta decay experiment by rigorously assessing material radiopurity.
  • To identify and qualify ultra-pure materials for shielding, pressure vessel, field cage, and detector components.
  • To measure and mitigate airborne radon levels at the Canfranc Underground Laboratory to reduce background interference.
  • To optimize radon suppression systems using nitrogen flushing and sealing strategies prior to detector commissioning.
  • To inform the background model of NEXT-100 using quantitative radiopurity data from HPGe, GDMS, and ICPMS.

Proposed method

  • Ultra-low background high-purity germanium (HPGe) gamma spectrometry was performed at 2450 m.w.e. depth in the Canfranc Underground Laboratory using p-type coaxial detectors with copper and lead shielding.
  • Complementary material radiopurity analysis was conducted via Glow Discharge Mass Spectrometry (GDMS) and Inductively Coupled Plasma Mass Spectrometry (ICPMS) for U, Th, and K concentrations.
  • In-situ radon measurements were carried out using AlphaGuard and custom micromegas-based radon detectors during various operational conditions of the lead castle.
  • Radon mitigation strategies were tested through sequential nitrogen purges and variable nitrogen gas fluxes (180–900 L/h) to assess their impact on radon concentration.
  • Gamma background rates were monitored in real time using a NaI(Tl) scintillator to correlate with radon levels and shielding effectiveness.
  • GEANT4 simulations were used to estimate detection efficiency for each sample in the HPGe measurements.

Experimental results

Research questions

  • RQ1What is the radiopurity level of key materials used in the NEXT detector components, including shielding, pressure vessel, and readout planes?
  • RQ2How effective are nitrogen flushing and sealing strategies in reducing airborne radon levels inside the lead castle at the Canfranc Underground Laboratory?
  • RQ3What is the contribution of residual radon and material radioactivity to the overall background model of the NEXT-100 experiment?
  • RQ4Can ultra-low background HPGe spectrometry, GDMS, and ICPMS provide consistent and reliable radiopurity data for detector construction?
  • RQ5What is the optimal radon mitigation strategy to achieve the required background level of 8×10⁻⁴ counts keV⁻¹kg⁻¹y⁻¹?

Key findings

  • The radiopurity screening identified CuA1 (ETP) copper and refurbished OPERA lead as suitable materials, with 210Pb activity measured at (76.4 ± 8.6) Bq/kg, confirming the nominal value of 80 Bq/kg.
  • After melting and reprocessing, the OPERA lead showed no contamination, validating its use in the shielding structure.
  • Sealing the lead castle reduced the gamma background rate from 59.56 Hz to 1.089 Hz, a two-order-of-magnitude reduction.
  • High-flow nitrogen flushing (900 L/h) reduced radon activity inside the castle from ~70 Bq/m³ to 4 Bq/m³, achieving a 17.5-fold reduction.
  • The radon activity inside the castle dropped to the detection limit of the AlphaGuard detector under high-flow nitrogen, indicating effective mitigation.
  • The combination of sealing and high-flow nitrogen flushing proved most effective, with radon levels becoming insensitive to external fluctuations.

Read this paper