[Paper Review] Randomly Initialized Convolutional Neural Network for the Recognition of COVID-19 using X-ray Images
This paper proposes a randomly initialized Convolutional Neural Network (CNN) for detecting COVID-19 from chest X-ray images, training the architecture from scratch without transfer learning. Evaluated on two public datasets—COVIDx and enhanced COVID-19—the model achieves 94% and 99% accuracy, respectively, demonstrating strong performance without pre-trained weights.
By the start of 2020, the novel coronavirus disease (COVID-19) has been declared a worldwide pandemic. Because of the severity of this infectious disease, several kinds of research have focused on combatting its ongoing spread. One potential solution to detect COVID-19 is by analyzing the chest X-ray images using Deep Learning (DL) models. In this context, Convolutional Neural Networks (CNNs) are presented as efficient techniques for early diagnosis. In this study, we propose a novel randomly initialized CNN architecture for the recognition of COVID-19. This network consists of a set of different-sized hidden layers created from scratch. The performance of this network is evaluated through two public datasets, which are the COVIDx and the enhanced COVID-19 datasets. Both of these datasets consist of 3 different classes of images: COVID19, pneumonia, and normal chest X-ray images. The proposed CNN model yields encouraging results with 94% and 99% of accuracy for COVIDx and enhanced COVID-19 dataset, respectively.
Motivation & Objective
- To develop a deep learning model for early detection of COVID-19 using chest X-ray images.
- To investigate the performance of a CNN trained from random initialization, without pre-trained weights.
- To evaluate the model on diverse public datasets containing normal, pneumonia, and COVID-19 X-ray images.
- To demonstrate that a custom-architected CNN can achieve high accuracy without transfer learning.
Proposed method
- A novel CNN architecture is designed from scratch with multiple hidden layers of varying sizes.
- The network is trained end-to-end using stochastic gradient descent with cross-entropy loss.
- Data augmentation techniques are applied to improve generalization and reduce overfitting.
- The model is evaluated on two public datasets: COVIDx and an enhanced COVID-19 dataset.
- Training is performed using only random initialization, avoiding any ImageNet or other pre-trained weights.
- The architecture is optimized through hyperparameter tuning and early stopping to prevent overfitting.
Experimental results
Research questions
- RQ1Can a randomly initialized CNN achieve high accuracy in classifying COVID-19 from chest X-ray images without transfer learning?
- RQ2How does the performance of a custom CNN compare to pre-trained models on public COVID-19 X-ray datasets?
- RQ3What is the impact of data augmentation and architectural design on model generalization in low-data regimes?
- RQ4Can a CNN trained from scratch effectively distinguish between normal, pneumonia, and COVID-19 X-ray images?
Key findings
- The proposed CNN achieved 94% accuracy on the COVIDx dataset, which contains normal, pneumonia, and COVID-19 X-ray images.
- On the enhanced COVID-19 dataset, the model reached 99% accuracy, indicating strong generalization on improved data.
- The results demonstrate that random initialization can yield competitive performance without relying on pre-trained ImageNet weights.
- The model's performance highlights the effectiveness of architectural design and data augmentation in few-shot medical imaging tasks.
- The absence of transfer learning did not hinder performance, suggesting that custom training can be sufficient for specialized medical classification.
- The model shows robustness across different data distributions, particularly when data quality and diversity are enhanced.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.