Skip to main content
QUICK REVIEW

[Paper Review] Rapid measurement of the local pressure amplitude in microchannel acoustophoresis using motile cells

Minji Kim, Rune Barnkob|arXiv (Cornell University)|Apr 3, 2021
Microfluidic and Bio-sensing TechnologiesEngineering36 references10 citations
TL;DR

This paper proposes using motile Chlamydomonas reinhardtii algae as active probes to rapidly and quantitatively measure local acoustic energy density in microchannel acoustophoresis. By correlating the cells' dynamic redistribution under acoustic fields with known acoustophysical properties, the method achieves real-time, in situ performance monitoring with 1% agreement to conventional passive particle tracking, reducing measurement time from hours to minutes.

ABSTRACT

Acoustic microfluidics (or acoustofluidics) provides a non-contact and label-free means to manipulate and interrogate bioparticles. Owing to their biocompatibility and precision, acoustofluidic approaches have enabled innovations in various areas of biomedical research. Future breakthroughs will rely on translation of these techniques from academic labs to clinical and industrial settings. Here, accurate characterization and standardization of device performance is crucial. Versatile, rapid, and widely accessible performance quantification is needed. We propose a field quantification method using motile Chlamydomonas reinhardtii algae cells. We previously reported qualitative mapping of acoustic fields using living microswimmers as active probes. In the present study, we extend our approach to achieve the challenging quantitative in situ measurement of the acoustic energy density. C. reinhardtii cells continuously swim in an imposed force field and dynamically redistribute as the field changes. This behavior allows accurate and complete, real-time performance monitoring, which can be easily applied and adopted within the acoustofluidics and broader microfluidics research communities. Additionally, the approach relies only on standard bright-field microscopy to assess the field under numerous conditions within minutes. We benchmark the method against conventional passive-particle tracking, achieving agreement within 1 % for field strengths from 0 to 100 J m-3 (0 to ~1 MPa).

Motivation & Objective

  • To address the lack of rapid, accurate, and accessible performance characterization methods for acoustofluidic devices.
  • To overcome limitations of passive particle tracking, such as time-consuming trajectory tracing and inability to monitor dynamic changes in real time.
  • To develop a field-deployable, cost-effective method for in situ quantification of acoustic energy density and pressure amplitude.
  • To enable real-time monitoring of parametric sensitivities in acoustofluidic systems under varying operating conditions.
  • To establish a standardized, biocompatible probe system for device calibration and performance validation in biomedical and industrial applications.

Proposed method

  • Utilizes motile Chlamydomonas reinhardtii cells as active probes that dynamically redistribute in response to acoustic fields.
  • Employs bright-field microscopy to capture real-time cell distribution patterns across the microchannel under varying acoustic conditions.
  • Correlates the spatial distribution density of swimming cells (Λ) with acoustic radiation force and energy density using known acoustophysical properties of the cells.
  • Applies the acoustic energy density formula Eac = pa² / (4ρoco²) to derive pressure amplitude from measured Eac values.
  • Calibrates the method by comparing results against conventional passive particle tracking using polystyrene beads.
  • Uses in situ measurements of swimming speed and reorientation time to account for biological variability and maintain accuracy over time.

Experimental results

Research questions

  • RQ1Can motile C. reinhardtii cells serve as reliable, real-time probes for quantifying local acoustic energy density in acoustofluidic devices?
  • RQ2How does the dynamic redistribution of swimming cells correlate with acoustic field strength and energy density in microchannels?
  • RQ3To what extent does the motile cell-based method match the accuracy of conventional passive particle tracking under varying drive voltages and conditions?
  • RQ4Can this method detect and adapt to temporal changes in cell behavior or system parameters without recalibration?
  • RQ5What is the range of acoustic energy densities (and corresponding pressure amplitudes) that can be accurately measured using this approach?

Key findings

  • The motile cell-based method achieves 1% agreement with conventional passive particle tracking across acoustic energy densities from 0 to 100 J m⁻³.
  • The method reduces characterization time from several hours to just minutes, enabling rapid, real-time performance monitoring.
  • The acoustic energy density scales linearly with drive voltage, with a consistent relationship observed across multiple experimental trials.
  • The method remains accurate for up to 21 minutes after initial setup, with only minor deviations observed after 30 minutes, which can be corrected via in situ swimming speed measurements.
  • The pressure amplitude derived from Eac ranges from 0 to approximately 1 MPa, covering the relevant range for most acoustofluidic applications.
  • C. reinhardtii cells are shown to be a viable, low-cost, and accessible alternative to passive beads for device calibration and performance quantification.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.