TL;DR

This paper presents a versatile Surface Acoustic Wave (SAW) toolbox using an array of 32 interdigitated transducers (IDTs) and an inverse filter technique to synthesize diverse wave-fields—plane, focused, and swirling SAWs—on a single platform. The system enables on-chip manipulation of droplets, including displacement, division, fusion, and nebulization, with full reconfigurability via software-controlled excitation.

ABSTRACT

Surface acoustic waves (SAWs) are versatile tools to manipulate fluids at small scales for microfluidics and bio- logical applications. A non-exhaustive list of operations that can be performed with SAW includes sessile droplet displacement, atomization, division and merging but also the actuation of fluids embedded in microchannels or the manipulation of suspended particles. However, each of these operations requires a specific design of the wave generation system, the so-called interdigitated transducers (IDTs). Depending on the application, it might indeed be necessary to generate focused or plane, propagating or standing, aligned or shifted waves. Furthermore, the possibilities offered by more complex wave-fields such as acoustical vortices for particle tweezing and liquid twisting cannot be explored with classical IDTs. In this paper, we show that the inverse filter technique coupled with an interdigitated transducers array (IDTA) enables to synthesize all classical wave-fields used in microfluidics and biological applications with a single multi- function platform. It also enables to generate swirling SAWs, whose potential for the on-chip synthesis of tailored acoustical vortices has been demonstrated lately. The possibilities offered by this platform is illustrated by performing successively many operations on sessile droplets with the same system.

Motivation & Objective

  • To overcome the limitation of conventional IDTs, which require custom designs for each microfluidic operation, by developing a single, reconfigurable SAW platform.
  • To enable the synthesis of complex wave-fields—such as focused, plane, and swirling SAWs—on a single substrate using a single transducer array.
  • To demonstrate the feasibility of generating acoustical vortices and 3D particle manipulation via swirling SAWs, which are unattainable with standard IDTs.
  • To achieve multi-functional fluidic operations (displacement, division, fusion, nebulization) on sessile droplets using the same hardware platform.
  • To explore the potential of IDT arrays as both actuators and sensors for real-time droplet localization without external imaging.

Proposed method

  • An array of 32 optimized unidirectional interdigitated transducers (IDTs) is fabricated on a 1.05 mm thick X-cut LiNbO₃ substrate using a lift-off process with Ti/Au layers.
  • The IDTs are designed to operate at 11.9 MHz and are placed along a slowness curve with slight curvature to enhance spatial illumination of the central 5 mm 'acoustical scene'.
  • Each IDT is independently driven by programmable electronics with impedance matching via external inductors to ensure efficient energy transfer.
  • The inverse filter technique is adapted from bulk wave applications to compute the optimal time-domain input signals for each IDT to synthesize a desired wave-field.
  • The method accounts for the anisotropy of the LiNbO₃ substrate and enables precise control over wavefront shape, direction, and topological charge (e.g., swirling SAWs with topological order 0, 2).
  • The system enables dynamic reconfiguration of wave-fields in real time, allowing sequential execution of multiple fluidic operations on the same droplet or substrate.

Experimental results

Research questions

  • RQ1Can a single SAW platform synthesize multiple wave-field types (plane, focused, swirling) using a single transducer array?
  • RQ2To what extent can the inverse filter technique be adapted to surface acoustic waves on anisotropic substrates for complex wave-field synthesis?
  • RQ3Can this platform perform a broad range of microfluidic operations—displacement, division, fusion, nebulization—on sessile droplets without hardware reconfiguration?
  • RQ4Is it possible to generate acoustical vortices with tunable topological charge using this IDT array and inverse filtering approach?
  • RQ5Can the IDT array function as both actuator and sensor for real-time droplet localization, reducing reliance on external imaging?

Key findings

  • The system successfully synthesized plane SAWs in multiple directions, enabling controlled displacement of a 2 µL droplet with a time resolution of 27 ms between frames.
  • Focalized SAWs were used to merge two 2 µL droplets into one, with fusion observed in a stack of images taken every 27 ms, confirming precise spatial control.
  • A swirling SAW of topological order 2 was generated to induce droplet division, achieving asymmetric splitting into two unequal-volume droplets with angular apodization.
  • High-intensity centered swirling SAWs of order 0 (annular wave) induced nebulization of a 2 µL droplet, with images captured every 13 ms, demonstrating atomization capability.
  • The inverse filter method enabled accurate wave-field synthesis despite substrate anisotropy, allowing the generation of complex fields such as acoustical vortices.
  • The platform’s reconfigurability allowed sequential execution of four distinct operations—displacement, division, fusion, and nebulization—on the same droplet using the same hardware setup.