[Paper Review] RCPS: Rectified Contrastive Pseudo Supervision for Semi-Supervised Medical Image Segmentation
RCPS introduces rectified pseudo supervision and bidirectional voxel contrastive learning to improve semi-supervised medical image segmentation, achieving state-of-the-art results on public and in-house datasets.
Medical image segmentation methods are generally designed as fully-supervised to guarantee model performance, which require a significant amount of expert annotated samples that are high-cost and laborious. Semi-supervised image segmentation can alleviate the problem by utilizing a large number of unlabeled images along with limited labeled images. However, learning a robust representation from numerous unlabeled images remains challenging due to potential noise in pseudo labels and insufficient class separability in feature space, which undermines the performance of current semi-supervised segmentation approaches. To address the issues above, we propose a novel semi-supervised segmentation method named as Rectified Contrastive Pseudo Supervision (RCPS), which combines a rectified pseudo supervision and voxel-level contrastive learning to improve the effectiveness of semi-supervised segmentation. Particularly, we design a novel rectification strategy for the pseudo supervision method based on uncertainty estimation and consistency regularization to reduce the noise influence in pseudo labels. Furthermore, we introduce a bidirectional voxel contrastive loss to the network to ensure intra-class consistency and inter-class contrast in feature space, which increases class separability in the segmentation. The proposed RCPS segmentation method has been validated on two public datasets and an in-house clinical dataset. Experimental results reveal that the proposed method yields better segmentation performance compared with the state-of-the-art methods in semi-supervised medical image segmentation. The source code is available at https://github.com/hsiangyuzhao/RCPS.
Motivation & Objective
- Reduce dependency on large labeled datasets for medical image segmentation while maintaining high accuracy.
- Mitigate pseudo-label noise in semi-supervised learning through uncertainty-aware rectification and consistency regularization.
- Enhance feature-space separability via voxel-level bidirectional contrastive learning.
- Validate RCPS on multiple public benchmarks and an in-house clinical dataset to demonstrate clinical viability.
Proposed method
- Generate two augmented views of each input using intensity-based transforms to create robust pseudo supervision signals.
- Rectify pseudo supervision by incorporating prediction uncertainty and a consistency regularization term.
- Compute a bidirectional voxel-level contrastive loss to enforce intra-class coherence and inter-class separation in feature space.
- Apply a triplet learning framework that combines uncertainty rectification and consistency regularization.
- Use a voxel-wise sampling strategy that selects confident negatives for contrastive learning to reduce false negatives.
Experimental results
Research questions
- RQ1Can rectified pseudo supervision reduce the impact of noisy pseudo labels in semi-supervised segmentation?
- RQ2Does bidirectional voxel contrastive learning improve class separability in the feature space for medical images?
- RQ3How does RCPS perform versus state-of-the-art semi-supervised methods on public and clinical datasets?
- RQ4What is the effect of integrating rectified pseudo supervision and voxel contrastive learning on labeled-only baselines?
Key findings
- RCPS achieves the best segmentation performance among compared semi-supervised methods on LA and pancreas-CT datasets under 10% and 20% labeled data settings.
- On LA with 10% labeled data, RCPS raises DSC from 79.46 (fully supervised baseline) to 90.73, approaching full supervision (91.65).
- On pancreas-CT with 10% labeled data, RCPS achieves 76.62 DSC, outperforming all compared semi-supervised methods.
- RCPS demonstrates competitive results on the in-house TBI dataset, with 71.88% DSC on labeled scans in cross-validation.
- The method consistently improves HD95/ASD metrics, indicating better boundary localization and surface accuracy.
- RCPS outperforms state-of-the-art methods across multiple datasets, highlighting the effectiveness of combining rectified pseudo supervision with voxel-level contrastive learning.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.