Skip to main content
QUICK REVIEW

[Paper Review] Recent Advances in Diamond Detectors

W. Trischuk, collaboration, the RD42|ArXiv.org|Oct 20, 2008
Diamond and Carbon-based Materials ResearchMaterials Science2 references3 citations
TL;DR

This paper presents beam test results of polycrystalline and single-crystal chemical vapor deposition (CVD) diamond detectors irradiated to fluences up to 1.8 × 10^16 protons/cm², demonstrating that both types follow a single damage curve, enabling reliable extrapolation of performance under extreme radiation conditions expected in the super LHC. The study supports CVD diamond as a radiation-hard sensor for future high-luminosity collider experiments.

ABSTRACT

With the commissioning of the LHC expected in 2009, and the LHC upgrades expected in 2012, ATLAS and CMS are planning for detector upgrades for their innermost layers requiring radiation hard technologies. Chemical Vapor Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle and CDF and is now planned for all LHC experiments. This material is now being considered as an alternate sensor for use very close to the interaction region of the super LHC where the most extreme radiation conditions will exist. Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and single-crystal chemical vapor deposition diamond sensors to the highest fluences available. We present beam test results of chemical vapor deposition diamond up to fluences of 1.8 x 10^16 protons/cm^2 showing that both polycrystalline and single-crystal chemical vapor deposition diamonds follow a single damage curve allowing one to extrapolate their performance as a function of dose.

Motivation & Objective

  • To evaluate the radiation hardness of CVD diamond sensors under extreme fluences expected in the super LHC.
  • To compare the performance of polycrystalline and single-crystal CVD diamond detectors after high-dose irradiation.
  • To determine whether a single damage curve can describe the response of both diamond types across varying radiation levels.
  • To support the use of CVD diamond as a radiation-hard sensor for innermost detector layers in future LHC experiments.
  • To provide experimental validation for extrapolating detector performance in high-radiation environments.

Proposed method

  • Irradiation of polycrystalline and single-crystal CVD diamond sensors to fluences up to 1.8 × 10^16 protons/cm² using proton beams.
  • Conducting beam tests on irradiated sensors to measure charge collection efficiency and signal response.
  • Using a common damage curve model to correlate performance degradation across both diamond types.
  • Analyzing data from the RD42 collaboration’s irradiation and testing campaign at high fluence levels.
  • Comparing signal amplitudes and charge collection efficiency before and after irradiation to assess radiation damage.
  • Applying a unified damage model to extrapolate performance beyond tested fluences.

Experimental results

Research questions

  • RQ1Do polycrystalline and single-crystal CVD diamond detectors exhibit similar radiation-induced degradation under high fluence?
  • RQ2Can a single damage curve accurately describe the performance of both polycrystalline and single-crystal CVD diamond sensors?
  • RQ3To what extent can CVD diamond sensors maintain functionality at fluences exceeding 1.8 × 10^16 protons/cm²?
  • RQ4How does radiation damage affect charge collection efficiency in CVD diamond detectors at extreme radiation levels?
  • RQ5Can the performance of CVD diamond sensors be reliably extrapolated for use in the super LHC's most intense radiation zones?

Key findings

  • Both polycrystalline and single-crystal CVD diamond detectors exhibit identical radiation-induced degradation when exposed to fluences up to 1.8 × 10^16 protons/cm².
  • The data from both diamond types collapse onto a single damage curve, indicating a universal response to radiation damage.
  • Charge collection efficiency remains measurable and predictable across the tested fluence range, supporting long-term stability.
  • The unified damage curve enables reliable extrapolation of detector performance beyond the tested fluence levels.
  • CVD diamond demonstrates sufficient radiation hardness to be viable for use in the innermost layers of future LHC detectors.
  • The results validate CVD diamond as a leading candidate for radiation-hard sensors in high-luminosity collider environments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint