TL;DR

This paper proposes ReCTnet, a deep learning architecture combining convolutional and recurrent neural networks to detect pulmonary nodules in CT scans by modeling spatial dependencies across axial slices. It achieves 90.5% sensitivity with 4.5 false positives per scan on the LIDC/IDRI dataset, outperforming prior methods by leveraging LSTM layers to improve nodule discrimination without increasing false positives.

ABSTRACT

Computed tomography (CT) generates a stack of cross-sectional images covering a region of the body. The visual assessment of these images for the identification of potential abnormalities is a challenging and time consuming task due to the large amount of information that needs to be processed. In this article we propose a deep artificial neural network architecture, ReCTnet, for the fully-automated detection of pulmonary nodules in CT scans. The architecture learns to distinguish nodules and normal structures at the pixel level and generates three-dimensional probability maps highlighting areas that are likely to harbour the objects of interest. Convolutional and recurrent layers are combined to learn expressive image representations exploiting the spatial dependencies across axial slices. We demonstrate that leveraging intra-slice dependencies substantially increases the sensitivity to detect pulmonary nodules without inflating the false positive rate. On the publicly available LIDC/IDRI dataset consisting of 1,018 annotated CT scans, ReCTnet reaches a detection sensitivity of 90.5% with an average of 4.5 false positives per scan. Comparisons with a competing multi-channel convolutional neural network for multi-slice segmentation and other published methodologies using the same dataset provide evidence that ReCTnet offers significant performance gains.

Motivation & Objective

  • To address the challenge of low sensitivity and high false positive rates in automated pulmonary nodule detection from CT scans.
  • To develop a deep learning architecture that learns hierarchical image representations directly from raw CT data, avoiding handcrafted features.
  • To improve detection performance by modeling spatial dependencies across multiple axial CT slices using recurrent layers.
  • To demonstrate the effectiveness of end-to-end training with joint optimization of convolutional and recurrent components.
  • To explore architectural components such as attention mechanisms, dropout, and adaptive sampling for performance improvement.

Proposed method

  • ReCTnet combines 3D convolutional layers with bidirectional LSTMs to extract and propagate contextual features across adjacent CT slices.
  • The network processes a sequence of 7 axial slices centered on each voxel to model inter-slice anatomical context.
  • A fully connected multi-layer perceptron (MLP) classifies each voxel as nodule or non-nodule based on the LSTM-processed features.
  • End-to-end training is used to jointly optimize all network parameters, improving feature representation and generalization.
  • The architecture leverages dilated convolutions to maintain spatial resolution while expanding receptive fields for contextual aggregation.
  • A deterministic attention mechanism was tested to weight important image patches, but provided no performance gain over LSTM gating.

Experimental results

Research questions

  • RQ1Can a deep neural network that models inter-slice dependencies improve pulmonary nodule detection sensitivity without increasing false positives?
  • RQ2How does the integration of recurrent layers with convolutional networks enhance feature representation for small, low-contrast nodules in CT scans?
  • RQ3Does end-to-end training of a joint convolutional-recurrent architecture yield better performance than fine-tuning or pre-training?
  • RQ4What is the optimal number of adjacent slices needed to model sufficient anatomical context for accurate detection?
  • RQ5Can attention mechanisms or adaptive sampling strategies further improve detection performance in challenging cases?

Key findings

  • ReCTnet achieved a detection sensitivity of 90.5% on the LIDC/IDRI dataset, significantly outperforming previous methods and a competing multi-channel CNN.
  • The model maintained a low false positive rate of 4.5 per scan, indicating strong specificity despite high sensitivity.
  • The use of bidirectional LSTMs improved discrimination by effectively synthesizing information across adjacent slices.
  • End-to-end training was essential for optimal performance, as fine-tuning only the top layers yielded lower accuracy.
  • Adding a second LSTM layer improved performance over a single layer, demonstrating the benefit of deeper recurrent modeling.
  • Techniques such as attention mechanisms, dropout, and adaptive sampling did not yield measurable performance gains in this setup.