Skip to main content
QUICK REVIEW

[Paper Review] Report on LSST Next-generation Instrumentation Workshop, April 11, 12 2019

C. W. Stubbs, Katrin Heitmann|arXiv (Cornell University)|May 12, 2019
Astronomy and Astrophysical ResearchPhysics and Astronomy3 references3 citations
TL;DR

This paper summarizes discussions from the 2019 LSST Next-Generation Instrumentation Workshop, evaluating three potential post-initial-survey upgrades: continued imaging with new filters, replacing CCDs with alternative sensors, and converting LSST into a wide-field multi-object fiber-fed spectrograph. The key finding is that a fiber spectrograph with 30,000+ fibers offers the highest scientific return, though thermal and cost challenges limit infrared sensor adoption, while new filters offer a low-cost, high-impact alternative for imaging science.

ABSTRACT

The Large Synoptic Survey Telescope (LSST) is a wide-field imaging system of unprecedented etendue. The initial goal of the project is to carry out a ten year imaging survey in six broad passbands (ugrizy) that cover $350 nm < λ< 1.1 μm$. This document reports on the discussions that occurred at workshop (held April 11-12, 2019 at Argonne National Laboratory) that was convened to explore concepts for using the LSST system once the initial survey is complete. Participants discussed the tradeoffs in science performance, cost, and uniqueness for i) imaging surveys using the initial wide-field CCD instrument, perhaps supplemented with different filters, ii) replacing the focal plane with some alternative sensor technology, and iii) converting the LSST system to a wide-field multi-object fiber-fed spectrograph. Participants concluded that the fiber spectrograph option would be most effective if the focal plane were to feed upwards of 30,000 fibers. Thermal management and power considerations in the LSST instrument barrel make it difficult to accommodate infrared sensors that require very low operating temperatures, and the current generation of buttable IR sensors that would extend sensitivity to 2 $μ$m are, we concluded, cost-prohibitive. Procuring and using an alternative filter set, on the other hand, is modest in cost, would take full advantage of the LSST image reduction pipeline, and could yield considerable additional information.

Motivation & Objective

  • To evaluate the scientific and technical feasibility of next-generation instrumentation for the LSST after its initial 10-year survey.
  • To compare three main upgrade pathways: continued imaging with new filters, focal plane sensor replacement, and conversion to a multi-object spectrograph.
  • To identify technical risks and R&D priorities for each path to inform future instrument development.
  • To assess the trade-offs between scientific performance, cost, and preservation of LSST’s unique survey capability.
  • To guide the community in prioritizing future instrumentation investments based on engineering constraints and scientific potential.

Proposed method

  • Conducted a workshop at Argonne National Laboratory with 40+ international experts to evaluate technical and scientific trade-offs for LSST instrumentation evolution.
  • Evaluated imaging with new filters by analyzing beam geometry, filter fabrication tolerances, and performance metrics for narrowband applications.
  • Assessed alternative sensor technologies, including InGaAs and Ge CCDs, focusing on cost, fill factor, dark current, and thermal management challenges.
  • Explored the feasibility of a multi-object spectrograph using 30,000+ fibers, analyzing fiber coupling, pupil imaging, and atmospheric dispersion correction.
  • Identified key R&D tasks, including prototype testing of fiber coupling optics, sky subtraction methods, and atmospheric dispersion correctors at the fiber scale.
  • Used existing LSST infrastructure—especially the image reduction pipeline and data access tools—as a baseline for evaluating performance trade-offs.

Experimental results

Research questions

  • RQ1What are the scientific and technical trade-offs of continuing wide-field imaging with modified filter sets after the initial LSST survey?
  • RQ2Can alternative focal plane sensors, such as InGaAs or Ge CCDs, be practically implemented in the LSST instrument barrel given thermal and cost constraints?
  • RQ3What is the optimal design and performance envelope for a wide-field multi-object spectrograph using the LSST’s existing etendue?
  • RQ4How can systematic errors in fiber-fed spectroscopy—particularly sky subtraction and atmospheric dispersion—be minimized in a large-scale LSST spectrograph?
  • RQ5What R&D tasks are most critical to de-risk the transition to next-generation LSST instrumentation?

Key findings

  • A fiber-fed multi-object spectrograph with 30,000 or more fibers is the most scientifically effective next-generation option, offering broad redshift coverage and high multiplex advantage.
  • Thermal management and power constraints in the LSST instrument barrel make infrared sensors requiring cryogenic operation impractical, and current buttable IR sensors are cost-prohibitive.
  • Narrowband filters with ∆λ ∼ 20 nm are feasible and could significantly enhance science in large-scale structure, star formation, and photometric redshift studies.
  • Sky subtraction artifacts and differential atmospheric refraction pose major challenges for faint-object spectroscopy, requiring fiber-by-fiber atmospheric dispersion correction.
  • Prototype atmospheric dispersion correctors and optimized fiber coupling optics are essential to suppress systematic errors and enable high-fidelity spectroscopy.
  • The existing LSST image reduction pipeline and data infrastructure provide a strong foundation for continued imaging science, making filter upgrades a low-risk, high-impact option.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint