[Paper Review] Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory
This paper introduces a duality theory that unifies grid-forming (GFM) and grid-following (GFL) inverters by revealing their symmetric, technology-neutral relationship across synchronization, grid-interfacing, swing dynamics, and controller design. The key contribution is a formal duality framework showing that GFM and GFL inverters are duals in five key aspects, including frequency droop control and PLL, voltage/current forming/following, and instability mechanisms, enabling a unified analysis of small-signal and transient stability in both weak and strong grids.
Power electronic converters for integrating renewable energy resources into power systems can be divided into grid-forming and grid-following inverters. They possess certain similarities, but several important differences, which means that the relationship between them is quite subtle and sometimes obscure. In this article, a new perspective based on duality is proposed to create new insights. It successfully unifies the grid interfacing and synchronization characteristics of the two inverter types in a symmetric, elegant, and technology-neutral form. Analysis shows that the grid-forming and grid-following inverters are duals of each other in several ways including a) synchronization controllers: frequency droop control and phase-locked loop (PLL); b) grid-interfacing characteristics: current-following voltage-forming and voltage-following current-forming; c) swing characteristics: current-angle swing and voltage-angle swing; d) inner-loop controllers: output impedance shaping and output admittance shaping; and e) grid strength compatibility: strong-grid instability and weak-grid instability. The swing equations are also derived in dual form, which reveal the dynamic interaction between the grid strength, the synchronization controllers, and the inner-loop controllers. Insights are generated into cases of poor stability in both small-signal and transient/large-signal. The theoretical analysis and simulation results are used to illustrate cases for simple single-inverter-infinite-bus systems and a multi-inverter power network.
Motivation & Objective
- To resolve the long-standing ambiguity in the relationship between grid-forming (GFM) and grid-following (GFL) inverters, which are often treated as distinct despite structural similarities.
- To address the lack of a symmetric, technology-neutral analytical framework for comparing GFM and GFL inverters, especially in weak-grid and multi-inverter systems.
- To unify the analysis of synchronization, grid-interfacing behavior, and stability mechanisms across both inverter types using duality principles.
- To provide new insights into counterintuitive phenomena such as strong-grid instability in GFM inverters and islanding in GFL inverters through dual interpretations.
- To enable future multi-inverter system analysis by establishing a symmetric, scalable theoretical foundation based on duality.
Proposed method
- Propose a duality framework that maps GFM and GFL inverters across five key domains: synchronization controllers (frequency droop vs. PLL), grid-interfacing behavior (voltage-forming vs. current-forming), swing dynamics (voltage-angle vs. current-angle swing), inner-loop control (output impedance vs. admittance shaping), and grid strength compatibility.
- Use the complex dq± frame to derive dual forms of swing equations, enabling symmetric small-signal and transient stability analysis.
- Formulate dual relationships between key control parameters: e.g., frequency droop gain corresponds to PLL bandwidth, and voltage-loop bandwidth corresponds to current-loop bandwidth.
- Derive dual swing equations that reveal how grid strength, synchronization control, and inner-loop dynamics jointly influence system stability.
- Validate the duality using single-inverter-infinite-bus systems and a 14-bus multi-inverter network, demonstrating consistent dual behavior in stability and dynamic response.
- Introduce new concepts such as $i_d$-PLL, $v_q$-droop, and voltage/current strength to extend the duality framework to novel control designs.
Experimental results
Research questions
- RQ1How can the fundamental differences between grid-forming and grid-following inverters be reconciled through a symmetric, technology-neutral theoretical framework?
- RQ2In what ways are frequency droop control and phase-locked loop (PLL) operation duals of each other in terms of control structure and dynamic behavior?
- RQ3How does the duality between voltage-forming and current-forming behavior explain the stability characteristics of GFM and GFL inverters in weak and strong grids?
- RQ4Can the dual swing equations derived from the duality framework explain transient and small-signal instabilities in both inverter types?
- RQ5What new control concepts and interpretations emerge from applying duality to inverter-based power systems?
Key findings
- The frequency droop control in GFM inverters and the PLL in GFL inverters are duals, with the same mathematical structure when expressed in the complex dq± frame.
- Grid-forming and grid-following inverters are fundamentally duals in grid-interfacing behavior: one forms voltage and follows current, the other follows voltage and forms current.
- The swing equations for both inverter types are dual, revealing that both exhibit similar transient stability mechanisms involving virtual inertia and virtual damping.
- Strong-grid instability in GFM inverters and weak-grid instability in GFL inverters are dual phenomena, arising from opposite grid strength compatibilities: GFM is unstable under high grid strength (low impedance), while GFL is unstable under low grid strength (low admittance).
- Larger synchronization controller gains (e.g., droop gain or PLL bandwidth) and smaller inner-loop controller gains (e.g., voltage/current loop bandwidths) increase instability risk in both inverter types, confirming dual behavior in stability margins.
- The duality framework enables consistent analysis of multi-inverter systems and explains surprising behaviors such as islanding in GFL inverters and strong-grid instability in GFM inverters through dual interpretations of system dynamics.