Skip to main content
QUICK REVIEW

[Paper Review] Rough Transformers for Continuous and Efficient Time-Series Modelling

Fernando Moreno-Pino, Álvaro Arroyo|arXiv (Cornell University)|Mar 15, 2024
Neural Networks and ApplicationsComputer Science3 citations
TL;DR

This paper introduces the Rough Transformer (RFormer), a continuous-time deep learning model that leverages path signatures to enable efficient, robust, and accurate modeling of irregularly sampled time-series data. By incorporating multi-view signature attention that captures both local and global dependencies, RFormer achieves state-of-the-art performance on medical time-series tasks while reducing computational cost by up to 70% compared to standard Transformers.

ABSTRACT

Time-series data in real-world medical settings typically exhibit long-range dependencies and are observed at non-uniform intervals. In such contexts, traditional sequence-based recurrent models struggle. To overcome this, researchers replace recurrent architectures with Neural ODE-based models to model irregularly sampled data and use Transformer-based architectures to account for long-range dependencies. Despite the success of these two approaches, both incur very high computational costs for input sequences of moderate lengths and greater. To mitigate this, we introduce the Rough Transformer, a variation of the Transformer model which operates on continuous-time representations of input sequences and incurs significantly reduced computational costs, critical for addressing long-range dependencies common in medical contexts. In particular, we propose multi-view signature attention, which uses path signatures to augment vanilla attention and to capture both local and global dependencies in input data, while remaining robust to changes in the sequence length and sampling frequency. We find that Rough Transformers consistently outperform their vanilla attention counterparts while obtaining the benefits of Neural ODE-based models using a fraction of the computational time and memory resources on synthetic and real-world time-series tasks.

Motivation & Objective

  • To address the limitations of recurrent and standard Transformer models in handling long, irregularly sampled time-series data common in medical applications.
  • To reduce the quadratic computational cost of self-attention in Transformers when processing long sequences.
  • To enable robust performance across varying sampling frequencies and sequence lengths without retraining.
  • To integrate continuous-time representations into attention mechanisms using path signatures from rough path theory.
  • To achieve high performance comparable to Neural ODE-based models while significantly reducing memory and inference time.

Proposed method

  • The model uses piecewise-linear interpolation to convert irregularly sampled time-series into continuous functions.
  • It applies the path signature transform to extract hierarchical, iterated integral features from continuous trajectories, capturing both local and global dynamics.
  • A multi-view signature attention mechanism combines the full-path signature (S( X )_{0,t_k}) and local segment signature (S( X )_{t_{k-1},t_k}) at each time point to enrich attention representations.
  • The attention mechanism operates on a compressed sequence of signature features, reducing sequence length by up to 50% without loss of expressivity.
  • The architecture maintains permutation invariance and is invariant to sampling frequency changes, enabling robustness at inference.
  • The model is trained end-to-end using standard optimization with L2 loss, and signature hyperparameters are tuned for optimal performance.

Experimental results

Research questions

  • RQ1Can a Transformer-based architecture be made efficient and robust for long, irregularly sampled time-series without sacrificing performance?
  • RQ2Can path signatures be effectively integrated into attention mechanisms to improve modeling of continuous-time dynamics?
  • RQ3Does multi-view signature attention enhance sample efficiency and generalization across varying sampling frequencies?
  • RQ4How does the Rough Transformer compare in accuracy and efficiency to standard Transformers and Neural ODE-based models on real-world medical time-series?
  • RQ5Can the model maintain performance when input sequences are shortened or sampled at different frequencies?

Key findings

  • RFormer achieved a 171% improvement in test RMSE over the vanilla Transformer on the Heart Rate (HR) dataset, reducing error from 8.24 to 3.04.
  • On the HR dataset, RFormer maintained a test loss of 3.31 ± 0.05 under 50% random data drop, outperforming even Neural-RDE (4.67 ± 0.40) and showing minimal degradation.
  • The RFormer model reduced training time and memory usage by up to 70% compared to standard Transformers, while maintaining or improving performance.
  • The model demonstrated robustness to changes in sampling frequency and sequence length, unlike the vanilla Transformer, which suffered a 127% performance drop under data sparsity.
  • GRU and ODE-RNN models failed to learn meaningful representations, while Neural-CDE and Neural-RDE showed significant performance drops on irregularly sampled data.
  • The multi-view signature attention mechanism enabled the model to capture long-range dependencies more effectively than standard attention, even on shorter sequences.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint