[Paper Review] SAM Meets Robotic Surgery: An Empirical Study in Robustness Perspective
SAM shows strong zero-shot generalization with bounding box prompts in robotic instrument segmentation but underperforms with point prompts and unprompted settings, and lacks robustness under various corruptions.
Segment Anything Model (SAM) is a foundation model for semantic segmentation and shows excellent generalization capability with the prompts. In this empirical study, we investigate the robustness and zero-shot generalizability of the SAM in the domain of robotic surgery in various settings of (i) prompted vs. unprompted; (ii) bounding box vs. points-based prompt; (iii) generalization under corruptions and perturbations with five severity levels; and (iv) state-of-the-art supervised model vs. SAM. We conduct all the observations with two well-known robotic instrument segmentation datasets of MICCAI EndoVis 2017 and 2018 challenges. Our extensive evaluation results reveal that although SAM shows remarkable zero-shot generalization ability with bounding box prompts, it struggles to segment the whole instrument with point-based prompts and unprompted settings. Furthermore, our qualitative figures demonstrate that the model either failed to predict the parts of the instrument mask (e.g., jaws, wrist) or predicted parts of the instrument as different classes in the scenario of overlapping instruments within the same bounding box or with the point-based prompt. In fact, it is unable to identify instruments in some complex surgical scenarios of blood, reflection, blur, and shade. Additionally, SAM is insufficiently robust to maintain high performance when subjected to various forms of data corruption. Therefore, we can argue that SAM is not ready for downstream surgical tasks without further domain-specific fine-tuning.
Motivation & Objective
- Assess SAM's zero-shot segmentation performance in robotic surgery under bounding box and point prompts.
- Evaluate the robustness of SAM to data corruptions and perturbations across EndoVis 2017 and 2018 datasets.
- Investigate SAM's automatic mask generation in unprompted surgical scenes.
- Compare SAM against traditional supervised segmentation methods in binary and instrument-wise tasks.
Proposed method
- Use SAM with bounding box and single-point prompts to generate binary and instrument-wise segmentation on EndoVis 2017 and 2018 datasets.
- Label bounding boxes and derive instrument-wise labels from prompts to mitigate misclassification errors.
- Assess SAM under 18 corruption types at 5 severity levels following a robustness benchmark.
- Evaluate SAM's unprompted automatic mask generation on surgical scenes with default settings.
Experimental results
Research questions
- RQ1Can SAM achieve accurate instrument segmentation in robotic surgery when prompted with bounding boxes or points?
- RQ2How does SAM's performance degrade under common data corruptions and perturbations compared to other methods?
- RQ3Is SAM reliable for automatic unprompted surgical scene segmentation without prompts?
Key findings
- With bounding box prompts, SAM outperforms several prior supervised methods for binary and instrument-wise segmentation on EndoVis 2017 and 2018.
- Single-point prompts degrade performance substantially, indicating heavy reliance on strong prompts.
- SAM struggles to segment entire instruments in complex scenes or with overlapping instruments within the same bounding box.
- Under data corruptions, SAM exhibits notable performance degradation across most corruption types and severities, with JPEG and Gaussian noise being particularly impactful.
- Unprompted automatic mask generation yields fragmented masks and limited instrument semantics in surgical scenes, limiting practical downstream use.