[Paper Review] SAM Meets Robotic Surgery: An Empirical Study on Generalization, Robustness and Adaptation
This study evaluates the Segment Anything Model (SAM) for robotic surgical instrument segmentation, revealing its limitations in zero-shot generalization under complex conditions like overlapping instruments, reflections, and data corruption. To address these issues, the authors propose SurgicalSAM via LoRA fine-tuning, achieving state-of-the-art performance without prompts, demonstrating class-wise mask prediction and improved robustness in surgical scenarios.
The Segment Anything Model (SAM) serves as a fundamental model for semantic segmentation and demonstrates remarkable generalization capabilities across a wide range of downstream scenarios. In this empirical study, we examine SAM's robustness and zero-shot generalizability in the field of robotic surgery. We comprehensively explore different scenarios, including prompted and unprompted situations, bounding box and points-based prompt approaches, as well as the ability to generalize under corruptions and perturbations at five severity levels. Additionally, we compare the performance of SAM with state-of-the-art supervised models. We conduct all the experiments with two well-known robotic instrument segmentation datasets from MICCAI EndoVis 2017 and 2018 challenges. Our extensive evaluation results reveal that although SAM shows remarkable zero-shot generalization ability with bounding box prompts, it struggles to segment the whole instrument with point-based prompts and unprompted settings. Furthermore, our qualitative figures demonstrate that the model either failed to predict certain parts of the instrument mask (e.g., jaws, wrist) or predicted parts of the instrument as wrong classes in the scenario of overlapping instruments within the same bounding box or with the point-based prompt. In fact, SAM struggles to identify instruments in complex surgical scenarios characterized by the presence of blood, reflection, blur, and shade. Additionally, SAM is insufficiently robust to maintain high performance when subjected to various forms of data corruption. We also attempt to fine-tune SAM using Low-rank Adaptation (LoRA) and propose SurgicalSAM, which shows the capability in class-wise mask prediction without prompt. Therefore, we can argue that, without further domain-specific fine-tuning, SAM is not ready for downstream surgical tasks.
Motivation & Objective
- To assess SAM’s zero-shot generalization and robustness in robotic surgery using real-world endoscopic datasets.
- To investigate SAM’s performance under various prompts (bounding box, point-based) and unprompted settings.
- To evaluate SAM’s resilience to data corruptions and surgical scene complexities such as blur, blood, and reflections.
- To develop and validate a domain-adapted version of SAM—SurgicalSAM—capable of class-wise segmentation without prompts.
- To benchmark SurgicalSAM against state-of-the-art supervised models in instrument segmentation tasks.
Proposed method
- Fine-tuned the ViT-H-based SAM using Low-rank Adaptation (LoRA) to adapt the model to surgical instrument segmentation without requiring prompt inputs.
- Anchored the adaptation on two MICCAI EndoVis datasets (2017 and 2018), with manually annotated bounding boxes and center-point prompts for evaluation.
- Trained SurgicalSAM using AdamW optimizer with weight decay, input resolution of 512×512, and standard cross-entropy loss for binary and instrument-wise segmentation.
- Evaluated robustness using the EndoVis18 validation split under five severity levels of synthetic corruptions (e.g., blur, noise, fog, JPEG artifacts).
- Used IoU and Dice metrics for quantitative comparison with 14 state-of-the-art models, including UNet, ISINet, and S3Net.
- Conducted ablation studies on prompt types and corruption levels to isolate failure modes of the original SAM in complex surgical scenes.
Experimental results
Research questions
- RQ1Can SAM generalize effectively to robotic surgical instrument segmentation without fine-tuning, particularly under point-based or unprompted settings?
- RQ2How does SAM perform under realistic surgical image corruptions such as blur, noise, fog, and motion?
- RQ3What are the failure modes of SAM when instruments overlap or exhibit complex textures like reflections and shadows?
- RQ4Can LoRA-based fine-tuning enable SAM to perform class-aware, prompt-free segmentation in surgical scenes?
- RQ5How does the performance of the fine-tuned SurgicalSAM compare to state-of-the-art supervised models in terms of mIoU and robustness?
Key findings
- SAM achieved 71.38% mIoU on EndoVis18 with bounding box prompts, demonstrating strong zero-shot generalization in simple scenarios.
- SAM failed to segment complete instruments under point-based prompts or unprompted settings, often missing parts like jaws or wrists.
- Performance degraded significantly under data corruption, with mIoU dropping to 3.79% under the highest severity level of Gaussian noise and 4.26% under blur corruption.
- SurgicalSAM achieved 71.38% mIoU on EndoVis18 validation split without any prompts, matching state-of-the-art models despite being a single-task, image-only architecture.
- SurgicalSAM required only 18.28MB of additional parameters, indicating high efficiency of the LoRA fine-tuning strategy.
- The model showed notable robustness degradation under blur and motion corruptions, indicating a need for further domain adaptation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.