Skip to main content
QUICK REVIEW

[Paper Review] SAXO+ upgrade : second stage AO system end-to-end numerical simulations

Charles Goulas, Fabrice Vidal|arXiv (Cornell University)|Jan 1, 2023
Adaptive optics and wavefront sensingPhysics and Astronomy2 citations
TL;DR

This paper presents end-to-end numerical simulations of SAXO+, a proposed two-stage adaptive optics upgrade for the SPHERE instrument on ESO's Very Large Telescope. By adding a high-bandwidth near-infrared pyramid wavefront sensor and a fast deformable mirror operating at 1–3 kHz, SAXO+ reduces star residuals in coronagraphic images by a factor of 10 compared to the current SAXO system, with optimal performance achieved at 2 kHz and a low first-stage gain of 0.05 in red star conditions.

ABSTRACT

SAXO+ is a proposed upgrade to SAXO, the AO system of the SPHERE instrument on the ESO Very Large Telescope. It will improve the capabilities of the instrument for the detection and characterization of young giant planets. It includes a second stage adaptive optics system composed of a dedicated near-infrared wavefront sensor and a deformable mirror. This second stage will remove the residual wavefront errors left by the current primary AO loop (SAXO). This paper focuses on the numerical simulations of the second stage (SAXO+) and concludes on the impact of the main AO parameters used to build the design strategy. Using an end-to-end AO simulation tool (COMPASS), we investigate the impact of several parameters on the performance of the AO system. We measure the performance in minimizing the star residuals in the coronagraphic image. The parameters that we study are : the second stage frequency, the photon flux on each WFS, the first stage gain and the DM number of actuators of the second stage. We show that the performance is improved by a factor 10 with respect to the current AO system (SAXO). The optimal second stage frequency is between 1 and 2 kHz under good observing conditions. In a red star case, the best SAXO+ performance is achieved with a low first stage gain of 0.05, which reduces the first stage rejection.

Motivation & Objective

  • To design and evaluate a second-stage adaptive optics system (SAXO+) to improve high-contrast imaging performance for detecting young giant exoplanets.
  • To address residual wavefront errors from the current SAXO system, particularly those caused by temporal and sensitivity limitations.
  • To optimize key AO parameters—second-stage frequency, photon flux, first-stage gain, and deformable mirror actuator count—for maximum performance.
  • To assess the feasibility and performance trade-offs of two candidate deformable mirrors (28×28 and 34×34 actuators) in the second stage.
  • To support the design of a two-stage AO system as a technology demonstrator for future ELT instruments, including ESO’s PCS/ELT roadmap.

Proposed method

  • Used the COMPASS end-to-end adaptive optics simulation tool, extended to support dual-loop operation with separate real-time computers for the first (SAXO) and second (SAXO+) stages.
  • Simulated a two-stage AO system with a visible Shack-Hartmann wavefront sensor (SAXO) and a near-infrared pyramid wavefront sensor (SAXO+) driving a high-bandwidth deformable mirror.
  • Conducted parametric simulations varying second-stage loop frequency (1–3 kHz), photon flux on the pyramid WFS, first-stage gain (0.05–0.3), and second-stage DM actuator count (28×28 and 34×34).
  • Measured performance through normalized intensity in coronagraphic images at angular separations from 1 to 15 λ/D, with star residuals as the primary metric.
  • Analyzed actuator stroke requirements and correction zone limits to assess DM feasibility under realistic atmospheric conditions.
  • Used a single atmospheric layer with 45° wind for turbulence simulation, focusing on 5-second exposure durations to evaluate stroke saturation risks.

Experimental results

Research questions

  • RQ1What is the optimal loop frequency for the second-stage AO system to minimize residual starlight in coronagraphic images?
  • RQ2How does reducing the first-stage gain affect the performance of the two-stage AO system, particularly for red targets?
  • RQ3What is the performance difference between a 28×28 and a 34×34 actuator deformable mirror in the second stage under realistic stroke and correction zone constraints?
  • RQ4How does the photon flux on the pyramid wavefront sensor influence the achievable wavefront correction and residual intensity?
  • RQ5To what extent does the second-stage AO system improve the raw contrast performance compared to the current SAXO system alone?

Key findings

  • The SAXO+ second-stage AO system improves star residual intensity in coronagraphic images by a factor of 10 compared to the current SAXO system under good observing conditions.
  • The optimal second-stage loop frequency is between 1 and 2 kHz, with 2 kHz providing a strong balance between performance and technical feasibility.
  • For red target observations, the best performance is achieved with a first-stage gain of 0.05, which reduces first-stage rejection and enables better overall wavefront correction.
  • The 34×34 deformable mirror provides a deeper and wider correction zone than the 28×28 mirror, achieving a normalized intensity of 6×10⁻⁶ at 3 λ/D compared to 10⁻⁵ with the 28×28 mirror.
  • At 15 λ/D, the 28×28 DM maintains a normalized intensity of 3.4×10⁻⁵, while the 34×34 DM reaches 7.2×10⁻⁵, indicating that the larger mirror is more effective in outer regions but closer to stroke saturation.
  • Actuators near the pupil edge are most likely to exceed stroke limits, with 1.4 µm and 1.9 µm maximum displacements for the 28×28 and 34×34 DMs, respectively, under 0.74” seeing, leaving margins of 9 µm and 5 µm after accounting for safety and non-common path aberrations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.