TL;DR

MARVUS integrates 2D ultrasound with mobile AR to reconstruct 3D nodules using a low-cost calibration phantom and edge-based segmentation, improving volumetric accuracy and reducing inter-user variability without heavy hardware. AR visuals also enhance user confidence and usability.

ABSTRACT

Accurate volumetric characterization of lesions is essential for oncologic diagnosis, risk stratification, and treatment planning. While imaging modalities such as Computed Tomography provide high-quality 3D data, 2D ultrasound (2D-US) remains the preferred first-line modality for breast and thyroid imaging due to cost, portability, and safety factors. However, volume estimates derived from 2D-US suffer from high inter-user variability even among experienced clinicians. Existing 3D ultrasound (3D-US) solutions use specialized probes or external tracking hardware, but such configurations increase costs and diminish portability, constraining widespread clinical use. To address these limitations, we present Mobile Augmented Reality Volumetric Ultrasound (MARVUS), a resource-efficient system designed to increase accessibility to accurate and reproducible volumetric assessment. MARVUS is interoperable with conventional ultrasound (US) systems, using a foundation model to enhance cross-specialty generalization while minimizing hardware requirements relative to current 3D-US solutions. In a user study involving experienced clinicians performing measurements on breast phantoms, MARVUS yielded a substantial improvement in volume estimation accuracy (mean difference: 0.469 cm3) with reduced inter-user variability (mean difference: 0.417 cm3). Additionally, we prove that augmented reality (AR) visualizations enhance objective performance metrics and clinician-reported usability. Collectively, our findings suggests that MARVUS can enhance US-based cancer screening, diagnostic workflows, and treatment planning in a scalable, cost-conscious, and resource-efficient manner. Usage video demonstration available (https://youtu.be/m4llYcZpqmM).

Motivation & Objective

  • Reduce cost and increase scalability of 3D ultrasound volumetric reconstruction across clinical specialties.
  • Develop a mobile AR workflow that works with standard 2D-US systems and minimal extra hardware.
  • Improve volumetric accuracy and reduce inter-operator variability in nodule measurements.
  • Provide AR visualizations that enhance clinician trust and usability in US-based workflows.

Proposed method

  • Calibration with a novel single-piece US phantom enabling single-frame spatial calibration.
  • Extrinsic calibration using ArUco markers on the probe, phantom, and camera to derive T_US_Probe and related transforms.
  • Reconstruction of nodules from freehand 2D-US sweeps into a textured 3D point cloud via multicamera pose tracking and a fixed reference frame.
  • Semi-automated nodule segmentation using EdgeTAM with multi-frame propagation to obtain a dense point cloud.
  • Voxelization and marching cubes to produce a mesh for volume estimation and AR visualization.
  • AR verification by overlaying the reconstructed mesh with live US data and displaying mesh-image intersections to assess reconstruction quality.

Experimental results

Research questions

  • RQ1Does MARVUS improve accuracy of ultrasound-based volumetric measurements compared with standard manual ellipsoid estimation?
  • RQ2Can AR visualizations reduce inter-operator variability in 3D-US nodule volume estimation?
  • RQ3Is the proposed calibration and reconstruction workflow robust across common ultrasound depths and gains?
  • RQ4Does integrating AR visualization enhance user trust and perceived usability of mobile 3D-US systems?

Key findings

  • MARVUS significantly improves volume estimation accuracy over the control method in expert-only tests (specific numerical values reported for comparison with baseline).
  • The AR-augmented workflow further reduces volume error and inter-operator variability compared to Recon alone.
  • Calibration reproducibility of the proposed single-frame, marker-based phantom is competitive with or better than several wire-based methods while avoiding specialized hardware.
  • Participants reported higher confidence using MARVUS with AR visuals, and system usability showed modest improvement with AR.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.