[Paper Review] Scheduling of EV Battery Swapping, I: Centralized Solution
This paper proposes a centralized optimization framework for electric vehicle (EV) battery swapping that jointly schedules station assignments and power flows to minimize total travel distance and generation cost. Using second-order cone programming (SOCP) relaxation of AC power flow and generalized Benders decomposition, the method achieves globally optimal solutions when the relaxation is exact, demonstrating computational efficiency and effectiveness in reducing voltage violations and unserved EVs in simulations.
We formulate an optimal scheduling problem for battery swapping that assigns to each electric vehicle (EV) a best station to swap its depleted battery based on its current location and state of charge. The schedule aims to minimize total travel distance and generation cost over both station assignments and power flow variables, subject to EV range constraints, grid operational constraints and AC power flow equations. To deal with the nonconvexity of power flow equations and the binary nature of station assignments, we propose a solution based on second-order cone programming (SOCP) relaxation of optimal power flow (OPF) and generalized Benders decomposition. When the SOCP relaxation is exact, this approach computes a globally optimal solution. We evaluate the performance of the proposed algorithm through simulations. The algorithm requires global information and is suitable for cases where the distribution network, stations, and EVs are managed centrally by the same operator. In Part II of the paper, we develop distributed solutions for cases where they are operated by different organizations that do not share private information.
Motivation & Objective
- To develop a centralized optimal scheduling framework for EV battery swapping that minimizes total travel distance and generation cost.
- To address the joint optimization of station assignments and power flows under AC power flow constraints and EV range limitations.
- To ensure grid operational constraints are satisfied, including voltage limits and power flow equations.
- To handle the nonconvexity of AC power flow and binary station assignment variables through convex relaxation and decomposition techniques.
- To evaluate the performance of the proposed algorithm in terms of computational efficiency and reduction of voltage violations and unserved EVs.
Proposed method
- The problem is formulated as a mixed-integer nonconvex optimization problem with binary station assignment variables and nonlinear AC power flow equations.
- Second-order cone programming (SOCP) relaxation is applied to the optimal power flow (OPF) subproblem to handle the nonconvex AC power flow equations.
- Generalized Benders decomposition is used to decompose the problem into a master problem (handling binary station assignments) and slave problems (solving convex OPF relaxations).
- The algorithm computes a globally optimal solution when the SOCP relaxation of OPF is exact, which holds for many practical radial distribution networks.
- The approach relies on global information including grid topology, impedance data, background loads, battery availability, and EV locations and states of charge.
- The method is implemented using Gurobi for the master problem and SDPT3 for the slave problems in MATLAB.
Experimental results
Research questions
- RQ1Can a centralized optimization framework jointly schedule EV battery swapping and power flow to minimize total travel and generation costs?
- RQ2How effective is SOCP relaxation in approximating the nonconvex AC power flow equations in real-world distribution networks?
- RQ3To what extent does the proposed method reduce voltage violations compared to a nearest-station policy?
- RQ4How does the algorithm perform in terms of computational efficiency as the number of EVs increases?
- RQ5What is the impact of battery availability and station congestion on unserved EVs under different assignment policies?
Key findings
- The SOCP relaxation of OPF was found to be exact in most cases on the SCE 56-bus distribution feeder, enabling global optimality.
- The proposed algorithm achieved global optimality efficiently, with computation time scaling reasonably with the number of EVs, as shown in simulations.
- The average computation time remained low even for 400 EVs, indicating computational feasibility for practical deployment.
- Compared to the nearest-station policy, the proposed method reduced the objective value by up to 15% when travel distance was weighted less heavily.
- Voltage drop violations (VDV) increased significantly under the nearest-station policy as EV numbers rose, especially when battery supply was insufficient at popular stations.
- Under the nearest-station policy, 25% of EVs on average remained unserved due to congestion at stations 3 and 4, while stations 1 and 2 had underutilized batteries.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.