Skip to main content
QUICK REVIEW

[Paper Review] Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors

M. Antonello, D. Bagliani|arXiv (Cornell University)|Mar 15, 2012
Neutrino Physics ResearchPhysics and Astronomy9 references29 citations
TL;DR

This experiment proposes a search for sterile neutrino oscillations at Δm² ~ 1 eV² using a CERN-SPS neutrino beam, employing two identical large liquid argon time projection chambers (LAr-TPCs) followed by magnetized muon spectrometers at near (300 m) and far (1600 m) positions. The method exploits identical neutrino spectra at both locations; any deviation in event distributions would indicate νμ → νs oscillations, with the spectrometers enabling precise muon charge and momentum measurements to suppress backgrounds and control systematics.

ABSTRACT

This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.

Motivation & Objective

  • Investigate the existence of sterile neutrinos beyond the Standard Model by probing anomalous neutrino oscillations at Δm² ~ 1 eV².
  • Address the long-standing anomalies in short-baseline neutrino experiments, such as the LSND and MiniBooNE results, which suggest the presence of additional light sterile neutrinos.
  • Achieve high-precision measurement of νμ and ν̄μ oscillations by minimizing systematic uncertainties through a near-far detector comparison.
  • Utilize the superior electron-pi-zero discrimination of LAr-TPCs to achieve near-lossless detection of electron neutrinos and suppress background.
  • Enable full separation of νμ and ν̄μ via muon charge identification in spectrometers, reducing misidentification biases at high momenta.

Proposed method

  • Deploy two identical large-volume LAr-TPCs (ICARUS T600) at 300 m (near) and 1600 m (far) from the CERN-SPS proton target.
  • Install magnetized spectrometers downstream of each LAr-TPC to measure muon momentum and charge using classical dipole magnets and a novel air-magnet concept.
  • Leverage the identical radial and energy spectra of the νe beam at both positions to cancel out cross-sections and experimental biases in the comparison.
  • Use the spectrometers' charge identification to distinguish νμ from ν̄μ, enabling clean separation of oscillation channels.
  • Apply the LAr-TPC's high-resolution imaging to reject π⁰ backgrounds and achieve full efficiency for νe detection.
  • Compare event distributions between near and far detectors; any discrepancy would signal νμ → νs oscillations with Δm² ~ 1 eV² and sin²(2θ_new) > 0.

Experimental results

Research questions

  • RQ1Do anomalous neutrino oscillations consistent with sterile neutrino production occur at Δm² ~ 1 eV²?
  • RQ2Can the νμ → νs oscillation hypothesis be confirmed or excluded using a near-far detector configuration with identical beam conditions?
  • RQ3To what extent can systematic uncertainties from muon misidentification be controlled using charge-identified muon spectrometers?
  • RQ4How effectively can LAr-TPCs suppress π⁰ and other backgrounds while maintaining high detection efficiency for electron neutrinos?
  • RQ5Can the combination of LAr-TPC imaging and spectrometer momentum measurements resolve the νμ and ν̄μ components with sufficient precision to detect small oscillation signals?

Key findings

  • The near and far detectors are designed to have nearly identical νe beam spectra, enabling a direct comparison that cancels out detector and cross-section biases.
  • The LAr-TPC's electron-pi-zero discrimination capability allows for near-lossless detection of νe events, minimizing background contamination.
  • Muon spectrometers with charge identification enable full separation of νμ and ν̄μ, reducing systematics from mis-identified muons at high momenta.
  • The use of two identical detectors at different baselines allows for a clean test of νμ → νs oscillations, with any observed difference attributed to new physics.
  • The proposed setup is optimized to probe the sterile neutrino parameter space with sin²(2θ_new) ~ 10⁻² to 10⁻³ and Δm² ~ 1 eV², consistent with anomalies in previous experiments.
  • The experiment is designed to achieve high sensitivity to oscillations at Δm² ~ 1 eV², providing a definitive test of the sterile neutrino hypothesis.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.