Skip to main content
QUICK REVIEW

[Paper Review] Search for Exotic Physics with the ANTARES Detector

Gabriela Emilia Păvălaş, N. Picot-Clémente|arXiv (Cornell University)|Aug 6, 2009
Astrophysics and Cosmic PhenomenaPhysics and Astronomy2 references5 citations
TL;DR

This paper presents dedicated search strategies for relativistic magnetic monopoles and slow nuclearites using the ANTARES neutrino telescope. By leveraging the cluster trigger and optimized reconstruction algorithms, the study achieves a sensitivity of ~10⁻¹⁶ cm⁻²s⁻¹sr⁻¹ for nuclearites with masses ≥10¹⁷ GeV, significantly improving existing limits.

ABSTRACT

Besides the detection of high energy neutrinos, the ANTARES telescope offers an opportunity to improve sensitivity to exotic cosmological relics. In this article we discuss the sensitivity of the ANTARES detector to elativistic monopoles and slow nuclearites. Dedicated trigger algorithms and search strategies are being developed to search or them. The data filtering, background rejection selection criteria are described, as well as the expected sensitivity of ANTARES to exotic physics.

Motivation & Objective

  • To extend the physics reach of the ANTARES neutrino telescope beyond high-energy neutrinos to include exotic cosmological relics.
  • To develop and implement specialized trigger algorithms and selection criteria for detecting relativistic magnetic monopoles and slow nuclearites.
  • To improve flux sensitivity limits for magnetic monopoles and non-relativistic nuclearites using data from the 12-line and 5-line detector configurations.
  • To optimize background rejection and signal identification for rare, high-luminosity events from exotic particles.

Proposed method

  • Utilized the ANTARES detector’s 'all-data-to-shore' data acquisition strategy, transmitting all PMT pulses above threshold for subsequent trigger processing.
  • Applied two trigger logics—directional and cluster triggers—based on local coincidences (L1 hits) and spatial clustering of hits across storeys.
  • Simulated monopole and nuclearite signals using known particle physics models, including Cherenkov light emission profiles and energy loss in water.
  • Implemented a two-stage selection: a linear cut in L1-triggered hits vs. L0 single hits to reject background, followed by a multiple-snapshot time-window cut (≤1 ms) to identify nuclearite events.
  • Used CORSIKA and MUPAGE codes to simulate atmospheric muons and neutrinos as dominant backgrounds.
  • Optimized selection criteria using data-driven background modeling, achieving 99.998% data reduction while preserving signal.

Experimental results

Research questions

  • RQ1What is the sensitivity of the ANTARES detector to relativistic magnetic monopoles with velocities β ≥ 0.74?
  • RQ2Can the cluster trigger improve detection efficiency for slow nuclearites compared to the directional trigger?
  • RQ3What are the optimal selection criteria to distinguish nuclearite events from atmospheric muon backgrounds?
  • RQ4What is the lower mass limit for detectable nuclearites using the directional trigger in the 5-line configuration?
  • RQ5How can data acquisition be enhanced to preserve long-duration nuclearite signals (up to ~1 ms)?

Key findings

  • The cluster trigger demonstrated higher efficiency than the directional trigger for detecting upgoing magnetic monopoles, leading to its exclusive use in monopole searches.
  • For nuclearites, a lower mass limit of 3×10¹⁶ GeV was achieved using the directional trigger in the 5-line configuration, with sensitivity reaching ~10⁻¹⁶ cm⁻²s⁻¹sr⁻¹ for masses ≥10¹⁷ GeV.
  • After applying the linear cut and multiple-snapshot time-window cut, 16.3% of simulated 3×10¹⁶ GeV nuclearite events and 96.2% of 1×10¹⁸ GeV events remained in the sample.
  • Simulated nuclearite events showed a distinct signature with multiple short-duration snapshots (<500 ns) and high single-hit multiplicity, enabling effective separation from muon backgrounds.
  • Test runs with the cluster trigger on simulated nuclearite data showed improved efficiency and a lower detectable mass limit than the directional trigger.
  • The study proposes implementing a new trigger to preserve data for ~20 ms to capture long-duration nuclearite signals, enhancing future sensitivity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.